Weight:
150 g (5.3 oz)
Application/Test Type:
Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.
Battery:
N/A
Communication:
USB, IEEE-488 (GPIB), RS-232 (serial), Fiber-Optic Serial
Digital Filtering:
N/A
Dimensions:
65 mm (2.55 in)
Dynamic Range:
1 to 1,000 Volts per Meter (Single Range)
Flatness:
Frequency correction OFF:
±1.0 dB @ 10 MHz
Frequency correction ON: typically
0.8 dB, 5 kHz–1 GHz
1.4 dB, 1 GHz–18 GHz
Frequency Range:
3 MHz to 18 GHz
Internal Data Memory:
None
Measurement Mode:
X-Y-Z and Composite
Operation Time:
Laser Powered - Seemless
Overload:
1,600 V/m CW 16,000 V/m Peak
PC Software:
Optional Software for setup, automation and monitoring available.
Recharging Time:
N/A
Resolution:
0.01 V/m
RF Field Probes:
E-Field
Sampling Rate:
20 msec/up to 50 samples per second, USB and
GPIB only
Sensors:
Three monopoles
Standards Met:
IEC/EN 61000-4-3
Temperature Reading Resolution:
None