Conducted RF Immunity Categories
Conducted RF Immunity
-
Teseq/Ametek CTS NSG 4070D RF Test Generator
SKU: 10549
Standards Met: IEC 61000-4-6, MIL-461 CS114, ISO 11452-4, DO-160 Section 20 Conducted SusceptibilityApplications: Bulk Current Injection Testing, RF Conducted ImmunityInternal Amplifiers: 50 or 100 Watts (or none)System Frequency Range: 4 kHz - 1 GHzInternal Amp Frequencies: 150 kHz to 230 MHz or 4 kHz to 400 MHzTypically In Stock -
RFCI-75 RF Conducted Immunity Generator, 100 kHz - 400 MHz
SKU: 8467
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6, ISO 11452-4Applications: Vehicle Component Disturbance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 50VrmsBCI Test Levels (w/ built-in amplifier): 10V/400mA/114 dBµATypically In Stock -
Teseq NSG 4070-75 RF Immunity System
SKU: 8435
Frequency Range: 150 kHz – 230 MHzOutput Power: 75 WattsMax Test Levels: 30 V EMFTest Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6$1,750.00In stock -
CDN M2/M3-16 Coupling Decoupling Network
SKU: 8696
Frequency Range: 150 kHz - 230 MHzMax RF Test Voltage: 30 VRF Input Power: 6 W (continuous)RF Input Connector: 50 Ω BNC femaleInput Voltage EuT (AE): 250 VAC, 400 VDC$390.00 - $3,900.00In Stock -
EMIC-20 EM Injection Clamp for IEC/EN 61000-4-6 Immunity Test
SKU: 7851
Standards: EN/IEC 61000-4-6Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): -.5 dB at 100 kHz to -4 dB at 1 GHz (Min -7 dB at 700 MHzConnector: N-type femaleDimensions: 632 mm x 120 mm x 80 mm$595.00 - $8,500.00Typically In Stock -
Schwarzbeck EMCL 6146 EM Coupling Clamp for 1" Cables
SKU: 10728
Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingConnector: N-type femaleDimensions: 610 x 75 x 135 mmFrequency Range: 10kHz - 1GHzMax. Cable Diameter: 23 mm$750.00 - $3,725.00In Stock -
Fischer F-203I-A-32MM 1.25" Diameter Injection Clamp
SKU: 10727
Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingConnector: N-type femaleDimensions: 610 x 75 x 135 mmFrequency Range: 10kHz - 1GHzMax. Cable Diameter: 23 mm$975.00 - $4,625.00Available for Rental in 2026 -
Teseq CDN ST08 Coupling Decoupling Network
SKU: 8413
Frequency Range: 10 kHz to 80 MHzApplication: CDN for screened eight lines with RJ45 connectorCurrent Rating: 1000 mAEUT Connector: BNC 50 ΩCommon mode impedance (EUT Port) 10 kHz to 26 MHz: 150 Ω ±20 Ω$1,600.00Typically in Stock -
FCC F-140 Bulk Current Injection Probe
SKU: 15365
Applications: RF Current Monitoring, EMC BCI Tests, Military EMC TestingMaximum input power: 100 WattsTest Standards: ISO 11452-4, IEC 61000-4-6 BCI, DO-160 Section 20, MIL-STD-461 CS114Hole Diameter: 1.57" ( 40mm )Frequency Range: 10 kHz - 1 GHz$295.00 - $2,150.00RENTAL ONLY | Typically In Stock -
3ctest TPT-7637-4C100 Coupling Transformer ISO 7637-4 Pulse B
SKU: 8736
Frequency Range: 1 kHz – 300 kHzMax Unsaturated Voltage: 100 @ f ≥ 1 kHzMax Current: 32EUT Max Current: 100In Stock -
CDN-M3-32A-HV AC + DC 1000V RF Coupling/Decoupling Network
SKU: 12165
Application/Test Type: unscreened supply lines (mains) AC + DC, RF Conducted DisturbancesCurrent Rating: up to 32 AmpsMax Voltage: up to 1,000 VoltsFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsInquire for Availability -
Teseq CDN M532 5-Line/32 Amp RF Coupling/Decoupling Network
SKU: 12093
Associated Equipment: RF Conducted Immunity Test SystemsCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)