Fischer Custom Communications FCC-LISN-50-25-1-2, 50 uH, 25 Amp, 2 Line LISN

Condition:
Used
Application/Test Type:
MIL-STD-461F, CISPR 25-1 Tests
Current Rating:
25 Amperes
Inductors:
50 µH
Mains & EUT Connections:
Multi-Contact Safety Socket
RF Connector:
Multi-Contact Safety Socket
Standards Met:
MIL-STD-461F, or CISPR 25-1
Voltage CISPR 16-1-2:
Yes"
DO-160F:
Yes
CISPR 22:
Yes
FCC:
Yes
ANSI C63.4:
YesRating=DC - 60Hz"
Manufacturer:
FCC
Online Orders Ship Same Day

 

Availability:

Rentals Ship Same Day

SKU:
11735

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Ordering Options & Title Breakdown:

FCC-LISN-[INDUCTANCE]-[AMPERAGE]-[# OF LINES]-[EUT PWR CONNECTION]

Network Inductance:

  • 5 uH
  • 50 uH
  • 250 uH

Max Current:

  • 16A
  • 25A
  • 32A
  • 50A
  • 100A
  • 200A
  • 400A
  • 500A

# Of Lines:

  • 1
  • 2
  • 4

Connector Codes:

01 Multi-Contact Safety Socket

02 Superior Plug and Jack Safety Socket

03 IEC 320, 10A / 16A Power

04 IEC 320, 16A / 20A Power

05 (Reserved for future use)

06 (Reserved for future use)

07 CEE 7/7 16A Schuko German Power

08 Nema 5-15, 15A US Power

09 Nema 5-20, 20A US Power

10 Nema 6-20, 20A US Power

11 750 mcm brass threaded bolt

Key Considerations

Manufacturer:
FCC
Application/Test Type:
MIL-STD-461F, CISPR 25-1 Tests
Current Rating:
25 Amperes
Inductors:
50 µH
Mains & EUT Connections:
Multi-Contact Safety Socket
RF Connector:
Multi-Contact Safety Socket
Standards Met:
MIL-STD-461F, or CISPR 25-1
Voltage CISPR 16-1-2:
Yes"
DO-160F:
Yes
CISPR 22:
Yes
FCC:
Yes
ANSI C63.4:
YesRating=DC - 60Hz"