EM Test DPA 500N Power Analyzer for Harmonics & Flicker

Condition:
Used
Standards Met:
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-11
Application/Test Type:
Medical Device EMC Testings
Manufacturer:
EM Test
Online Orders Ship Same Day

 

Availability:

Typically In Stock

SKU:
sku-242

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

EM Test DPA 500N Overview

Harmonics and interharmonics are caused by modern electronic power conditioning modules. Such, mostly non-linear, modules to control loads and to reduce power consumption is the source of voltage at unwanted frequencies superposed on the supply voltage.

Voltage fluctuations caused by varying load currents may influence the luminance or the spectral distribution of lighting systems. The impression of the unsteadiness of visual sensation induced by this light stimulus is called flicker.

The EM Test DPA 500N harmonics and flicker analyzer is used for single phase applications.

The DPA 500N is a fully compliant analyzer for harmonics and flicker as per the latest IEC/EN 61000-3-2, IEC/EN 61000-3-3 and JIS C 61000-3-2 requirements. It follows the design specifications as per IEC/EN 61000-4-7:2002 and Am.1:2008 (for Class A instruments) and IEC/EN 61000-4-15:2010.

Based on a real-time kernel and equipped with its own harddisk it allows to record the measuring data continuously without any gaps or overlapping. The rectangular measurement window is synchronized to each group of 10 or 12 cycles of the mains supply frequency (50Hz or 60Hz) by means of a digital PLL (Phase Lock Loop). A wide-range current input (up to 50A) avoids loss of measured data due to range switching that would occur when using different shunt resistors.

The classification of the measurement can be selected at any time, before or after the measurement has been performed. During all measurements the AC supply voltage is measured simultaneously with the current.

The built-in flicker impedance, which is automatically selected when doing flicker measurement, makes the EM Test DPA 500N a complete single-box unit for both harmonics and flicker analysis.

By means of an external current clamp (optional) the current range can be extended up to 140Arms and more.

EM Test DPA 500N Features:

  • Available in Single Phase Three Phase Models
  • Real-time data acquisition
  • Internal hard disk for data storage
  • 16-Bit A/D converter
  • Wide-range current input
  • Wide-range voltage input
  • Built-in lumped flicker impedance
  • High-sophisticated analyzing capability
  • USB interface for control and data transfer

[split]

EM Test DPA 500N Ordering Options:

  • DPA 500N: Single phase Harmonics & Flicker analyser with Flicker Impedance for 16A and the dpa.control software
  • DPA 503N: 3 Phase Harmonics & Flicker analyser (6 channels) and the dpa.control software

EM Test DPA 500N Key Considerations

Manufacturer:
EM Test
Standards Met:
IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-11
Application/Test Type:
Medical Device EMC Testings