Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps

Weight:
6.5 kg (14.3 LB.'s)
Application/Test Type:
5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
32 Amps Maximum
Decoupling of Common Mode Disturbance:
Greater than 30 dB
Dimensions:
6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
Frequency Range:
150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
Insertion Loss:
Greater than 0.1 dB
Mains & EUT Connections:
4 mm, safety (Optional IEC 320 16A)
RF Connector:
BNC, 50 Ω
RF Input Voltage:
Less than 30 V
Standards Met:
IEC 61000-4-6
Voltage Division Factor:
10 dB +3 dB / -1 dB
Voltage Rating:
AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
Manufacturer:
Teseq
Online Orders Ship Same Day

 

SKU:
sku-227

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Teseq CDN M5 5-Line Features:

  • 4 power lines, (2L+N+PE), (3L+PE), optional (3L+N)
  • Frequency range: 150 kHz to 230 MHz (optional 10 kHz - 80 MHz)
  • Designed for IEC/EN 61000-4-6
  • M4 application without PE
  • 4 mm banana sockets
  • Power Rating: 250VAC/400VDC line to ground

Teseq CDN M5 5-Line Configurations:

  • CDN M516A: CDN M5, 16 A, 230 MHz (banana), 3xL,N,PE
  • CDN M532: CDN M5, 32 A, 230 MHz (banana), 3xL,N,PE
  • CDN M532-10: CDN M5, 32 A, 10 kHz to 80 MHz (banana), 3xL, N, PE

Key Considerations

Manufacturer:
Teseq
Weight:
6.5 kg (14.3 LB.'s)
Application/Test Type:
5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Current Rating:
32 Amps Maximum
Decoupling of Common Mode Disturbance:
Greater than 30 dB
Dimensions:
6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
Frequency Range:
150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
Insertion Loss:
Greater than 0.1 dB
Mains & EUT Connections:
4 mm, safety (Optional IEC 320 16A)
RF Connector:
BNC, 50 Ω
RF Input Voltage:
Less than 30 V
Standards Met:
IEC 61000-4-6
Voltage Division Factor:
10 dB +3 dB / -1 dB
Voltage Rating:
AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec