Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines

Weight:
1.5 kg (3.3 lbs)
Application/Test Type:
Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low current
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 Ω
Current Rating:
200 mA to 4 Amps (refer to data sheet for exact model specifications)
Decoupling of Common Mode Disturbance:
10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)
Dimensions:
4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
Frequency Range:
10 kHz to 80 MHz or 150 kHz to 230/300 MHz
Mains & EUT Connections:
4 mm banana or D-Sub 25 pins
RF Connector:
BNC 50 Ω
RF Input Voltage:
30 Volts Max
Standards Met:
IEC 61000-4-6, CISPR 15
Voltage Division Factor:
150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dB
Voltage Rating:
AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications)
Manufacturer:
Teseq
Online Orders Ship Same Day

 

SKU:
sku-230

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Teseq CDN AF Series Features:

  • Coupling networks designed for IEC/EN 61000-4-6, CISPR 15 and more
  • Used for unscreened, unbalanced lines
  • Models with 4 mm banana sockets or D-Sub 25 pins
  • Models with frequency range 10 kHz to 80 MHz, 150 kHz to 230 MHz or up to 300 MHz

Teseq CDN AF Series Configurations:

  • CDN A120: CDN AF12, 230 MHz (15 Pin D-sub)
  • CDN A150: CDN AF15, 230 MHz (25 Pin D-sub)
  • CDN A201: CDN AF2, 150 kHz - 300 MHz (banana)
  • CDN A201-10: CDN AF2, 10 kHz - 80 MHz (banana)
  • CDN A301: CDN AF3, 150 - 300 MHz (banana)
  • CDN A301-10: CDN AF3, 10 kHz - 80 MHz (banana)
  • CDN A401: CDN AF4, 150 - 300 MHz (banana)
  • CDN A401-10: CDN AF4, 10 kHz - 80 MHz (banana)
  • CDN A501: CDN AF5, 150 kHz - 230 MHz (banana)
  • CDN A501-10: CDN AF5, 10 kHz - 80 MHz (banana)
  • CDN A701: CDN AF7, 230 (300) MHz (banana)
  • CDN A800: CDN AF8, 230 MHz with sub-D
  • CDN A801: CDN AF8, 150 kHz - 300 MHz (banana)
  • CDN A801-10: CDN AF8, 10 kHz - 80 MHz (banana)

Key Considerations

Manufacturer:
Teseq
Weight:
1.5 kg (3.3 lbs)
Application/Test Type:
Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low current
Common Mode Impedance:
150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 Ω
Current Rating:
200 mA to 4 Amps (refer to data sheet for exact model specifications)
Decoupling of Common Mode Disturbance:
10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)
Dimensions:
4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
Frequency Range:
10 kHz to 80 MHz or 150 kHz to 230/300 MHz
Mains & EUT Connections:
4 mm banana or D-Sub 25 pins
RF Connector:
BNC 50 Ω
RF Input Voltage:
30 Volts Max
Standards Met:
IEC 61000-4-6, CISPR 15
Voltage Division Factor:
150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dB
Voltage Rating:
AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications)