Teseq CDN 3083-Surge 620 Volt, 100-200 Amp Manual Coupler

Weight:
80 kg (176 LB's)
Application/Test Type:
Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
Current Rating:
100 Amp or 200 Amp continous depending on model
Dimensions:
850 x 520 x 345 mm
Mains & EUT Connections:
Fischer 105 series; Screw terminals, rated for 230 A
RF Input Voltage:
Max. 8 kV / 4 kA
Standards Met:
IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
Voltage Rating:
620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC
Manufacturer:
Teseq
Online Orders Ship Same Day

 

SKU:
sku-220

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Teseq CDN 3083-Surge Description:

The Teseq CDN 3083 manual coupling/decoupling network fulfills the requirements specified in the surge standard IEC / EN 61000-4-5: 2014. Designed for convenient use in a wide variety of test environments, the CDN 3083 can be placed on the floor or table-top or may be mounted on a wall in an EMC laboratory or development workshop. Since high current couplers must often be taken to remote test sites, the Teseq CDN 3083 can be easily disassembled into handy modules for moving.

The unit is fitted with wheels and brakes for use on ramps or uneven surfaces. Currents over 100 Amps per phase are allowed for short test periods (CDN 3083-S100). The CDN 3083 is designed to withstand frequently encountered inrush currents and, in extreme cases, can be overstressed until the internal environment has reached the maximum temperature.

Rugged connection terminals, as well as a solid housing are featured to ensure safe, reliable operation. The CDN 3083 is tested for safety in compliance with IEC 61010. Surge levels up to 8 kV / 4 kA with 1.2 / 50 μs combination wave can be coupled by the CDN 3083.

EUT supply voltages of up to 620 V rms or 620 VDC at 100 A are supported. The CDN 3083 is designed for simple and safe manual operation. All symmetrical and asymmetrical coupling modes of IEC / EN 61000-4-5 and ANSI C62.41 are supported by the CDN 3083.

Teseq CDN 3083 Features:

  • Suitable for 3 Phase Combination wave & Ring wave Surge Test
  • EUT Current: 3 x 100 Amp continuous
  • EUT Voltage: 620 Volts RMS
  • Manual CDN compatible with most transient immunity generators
  • Complies with IEC / EN 61000-4-5 and ANSI C62.45

Teseq CDN 3083 Configurations:

  • CDN 3083-S100 (Surge Only):
    • 100A 3-phase coupling / decoupling network
    • 620V with NSG 3060, 440V with NSG 3040 for surges to 8kV
    • requires INA 3080, 3084, 3085 or CDN 3061-x16. Traceable calibration certificate
  • CDN 3083-S200 (Surge Only):
    • 200A 3-phase coupling / decoupling network
    • 620V with NSG 3060, 440V with NSG 3040 for surges to 8kV
    • requires INA 3080, 3084, 3085 or CDN 3061-x16. Traceable calibration certificate

Teseq CDN 3083 Coupling Sets:

  • INA 3080 IEC: IEC Coupling Set for CDN 3083
  • INA 3080 ANSI/IEC: ANSI/IEC Coupling Set for CDN 3083

Teseq CDN 3083 Calibration Options:

  • NIST Standard Configuration
  • ISO 17025

Key Considerations

Manufacturer:
Teseq
Weight:
80 kg (176 LB's)
Application/Test Type:
Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)
Current Rating:
100 Amp or 200 Amp continous depending on model
Dimensions:
850 x 520 x 345 mm
Mains & EUT Connections:
Fischer 105 series; Screw terminals, rated for 230 A
RF Input Voltage:
Max. 8 kV / 4 kA
Standards Met:
IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41
Voltage Rating:
620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC