Overview
Teseq CDN 3083-Surge Description:
The Teseq CDN 3083 manual coupling/decoupling network fulfills the requirements specified in the surge standard IEC / EN 61000-4-5: 2014. Designed for convenient use in a wide variety of test environments, the CDN 3083 can be placed on the floor or table-top or may be mounted on a wall in an EMC laboratory or development workshop. Since high current couplers must often be taken to remote test sites, the Teseq CDN 3083 can be easily disassembled into handy modules for moving.
The unit is fitted with wheels and brakes for use on ramps or uneven surfaces. Currents over 100 Amps per phase are allowed for short test periods (CDN 3083-S100). The CDN 3083 is designed to withstand frequently encountered inrush currents and, in extreme cases, can be overstressed until the internal environment has reached the maximum temperature.
Rugged connection terminals, as well as a solid housing are featured to ensure safe, reliable operation. The CDN 3083 is tested for safety in compliance with IEC 61010. Surge levels up to 8 kV / 4 kA with 1.2 / 50 μs combination wave can be coupled by the CDN 3083.
EUT supply voltages of up to 620 V rms or 620 VDC at 100 A are supported. The CDN 3083 is designed for simple and safe manual operation. All symmetrical and asymmetrical coupling modes of IEC / EN 61000-4-5 and ANSI C62.41 are supported by the CDN 3083.
Teseq CDN 3083 Features:
- Suitable for 3 Phase Combination wave & Ring wave Surge Test
- EUT Current: 3 x 100 Amp continuous
- EUT Voltage: 620 Volts RMS
- Manual CDN compatible with most transient immunity generators
- Complies with IEC / EN 61000-4-5 and ANSI C62.45
Teseq CDN 3083 Configurations:
- CDN 3083-S100 (Surge Only):
- 100A 3-phase coupling / decoupling network
- 620V with NSG 3060, 440V with NSG 3040 for surges to 8kV
- requires INA 3080, 3084, 3085 or CDN 3061-x16. Traceable calibration certificate
- CDN 3083-S200 (Surge Only):
- 200A 3-phase coupling / decoupling network
- 620V with NSG 3060, 440V with NSG 3040 for surges to 8kV
- requires INA 3080, 3084, 3085 or CDN 3061-x16. Traceable calibration certificate
Teseq CDN 3083 Coupling Sets:
- INA 3080 IEC: IEC Coupling Set for CDN 3083
-
INA 3080 ANSI/IEC: ANSI/IEC Coupling Set for CDN 3083
Teseq CDN 3083 Calibration Options:
- NIST Standard Configuration
- ISO 17025