Com-Power CDN-M450E 150 MHz to 230 MHz Single line Plus Netural 50 Amp

Weight:
8 lbs. or 3.6 kg
AE and EUT Connections:
5.2 mm shrouded banana sockets
Application:
Four conductor power cable
Common Mode Impedance:
150 kHz - 24 MHz: 150Ω ± 20Ω 24 MHz - 80 MHz: 150Ω + 60Ω / -45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / -60Ω
Compliant Test Standards:
IEC / EN 61000-4-6, CISPR 16-1-2
Current Rating:
50 Amps AC / 35 Amps DC (Max
Decoupling of Common Mode Disturbance:
≥40dB (EUT/AE)
Dimensions:
7 x 7 x 16 ¾ inches or 17.7 x 17.7 x 42.5 cm
RF Input Connector:
50 Ω BNC (Female)
RF Input Voltage:
40 V (Max)
Voltage Division Factor:
9.5 dB +3 / -0.5
Voltage Rating:
250 VAC / 350 VDC (Line to Ground)
Manufacturer:
Com-Power
Online Orders Ship Same Day

 

SKU:
sku-1016

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

Com-Power CDN-M450E is a part of the series of Coupling/Decoupling Networks designed specifically for testing product for conducted immunity per IEC/EN 61000-4-6. The CDN-M450E is designed for testing products that uses four conductor power cable. It has five 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M450E can handle up to 50 Amps AC and 35 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding. All Com-Power CDNs are individually calibrated. The Com-Power CDN-M450E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system.

This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test. Coupling Decoupling Network CDN-M450E. During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to the power supply lines. In addition, CDNs provide required common mode impedance between the power supply lines and ground, minimize interference to the auxillary equipment via common mode decoupling of the disturbing signals and provide uninterrupted path for the power to the EUT. Before you begin testing with the CDN-M450E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150? to 50? adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value.

The CDN-M450E is designed for testing products that uses four conductor power cable. It has five 4 mm shrouded banana socket for both EUT and AE power connections. The CDN-M450E can handle up to 50 Amps AC and 35 Amps DC of current. The RF disturbance signal coupling port is female BNC. It can handle up to 40V of RF input Voltage. The bottom surface of the CDN is not painted for easy and effective grounding.

All Com-Power CDNs are individually calibrated. The Com-Power CDN-M450E fully complies with the requirement contained in the IEC 61000-4-6 and CISPR 16-1-2. All Com-Power CDNs can be purchased separately or as part of the CIS series conducted immunity test system. This is a pre-packaged solution that includes an ACS series power amplifier and all accessories required for the test.

Application

During conducted Immunity testing, CDNs are utilized to provide a means of coupling RF common mode signals to each line. In addition, CDNs provide the required common mode impedance to the EUT, isolation to the auxiliary equipment via common mode decoupling of the disturbance signals and provide uninterrupted communication between the EUT and auxiliary equipment.

Before you begin testing with the CDN-M450E you will need to establish calibrated drive levels corresponding to your desired test levels. During drive level calibration, the RF signal level being injected to the CDN is adjusted incrementally until the voltage level measured at the 150Ω to 50Ω adapter (ADA-515-2) connected to the EUT port is approximately equal to the Umr value given in the table below. The ADA-515-2 and accessories needed for this test are available from Com-Power.

Test Levels
Open Circuit Voltage
Umr
1 0.167
3 .5
< 10 1.67


Typical Data

Com-Power CDN-M450E Typical Data

Com-Power CDN-M450E Typical Data

Key Considerations

Manufacturer:
Com-Power
Weight:
8 lbs. or 3.6 kg
AE and EUT Connections:
5.2 mm shrouded banana sockets
Application:
Four conductor power cable
Common Mode Impedance:
150 kHz - 24 MHz: 150Ω ± 20Ω 24 MHz - 80 MHz: 150Ω + 60Ω / -45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / -60Ω
Compliant Test Standards:
IEC / EN 61000-4-6, CISPR 16-1-2
Current Rating:
50 Amps AC / 35 Amps DC (Max
Decoupling of Common Mode Disturbance:
≥40dB (EUT/AE)
Dimensions:
7 x 7 x 16 ¾ inches or 17.7 x 17.7 x 42.5 cm
RF Input Connector:
50 Ω BNC (Female)
RF Input Voltage:
40 V (Max)
Voltage Division Factor:
9.5 dB +3 / -0.5
Voltage Rating:
250 VAC / 350 VDC (Line to Ground)