3ctest High Frequency Noise Simulator for Immunity Performace Testing

Weight:
80 lbs. 37 kg.
Dimensions:
491×460×230mm
Polarity:
positive / negative
Pulse voltage (open circuit):
0.25~4kV 50Ω load or 0.25~2kV
Repetition time:
Approx. 20~50Hz
Supply Voltage:
AC single phase 220V, 16A or AC internal three-phase four-wire, 380V 16A
Manufacturer:
3ctest
Online Orders Ship Same Day

 

SKU:
sku-794

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

An Impulse Noise simulator is used to reproduce fast rise-up noises which are generated when switching ON / OFF electric current on the inductive load. It can be used for performance evaluation of electronic equipment upon reproduction of line noises which are intruded to the power supply lines or induced noises onto the telecommunication lines.

3ctest High Frequency Noise Simulator Description:

This 3ctest simulator is to produce steep pulse interference produced by on and off inductance load to assess the temporary conducted immunity performance of electronic equipment. It is most widely used for internal immunity performance test, radiated performance test of local part and system ground performance test

Complementary to the standard IEC/EN 61000-4-4.

Application:

  • Consumer products (white home appliances, AV equipment, etc.)
  • Industrial equipment (FA machines, controllers office machines, etc.)
  • Industrial equipments (Medical, entertainment, measurements, etc.)
  • Automotive equipments (Navigation, air-conditioner, audio, etc.)
  • Electronic component (Control board, mounted electronic components, etc.)
  • Railroad application
  • Security related equipments
  • Industrial controller related equipments

Industries:

  • Communication
  • Technology > Telecom
  • Military
  • Medical
  • Avionics
  • Broadcast
  • New energy
  • Railway
  • Electric Vehicle

Key Considerations

Manufacturer:
3ctest
Weight:
80 lbs. 37 kg.
Dimensions:
491×460×230mm
Polarity:
positive / negative
Pulse voltage (open circuit):
0.25~4kV 50Ω load or 0.25~2kV
Repetition time:
Approx. 20~50Hz
Supply Voltage:
AC single phase 220V, 16A or AC internal three-phase four-wire, 380V 16A

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.