EMC Partner CDN-KIT1000 ED3

Condition:
New
Standard:
IEC 61000-4-5
Application:
surge on 2 unsymmetrical lines
Test level surge:
max. 6 kV
EUT voltage per line:
max. 200 V DC or 240 V peak
EUT current per line:
max. 4 A cont. or 5 A for 5 min.
Manufacturer:
EMC Partner
Online Orders Ship Same Day

 

Availability:

Typically In Stock

 

Modular coupling and decoupling for 4 un-symmetrical signal and data lines used with Combination wave (CWG) generators according to IEC 61000-4-5. Used for carrying out surge into control,signal and data lines.

  • Standard: IEC 61000-4-5
  • Application: surge on 2 unsymmetrical lines
  • Test level surge: max. 6 kV
  • Low speed I/O: unsymmetrical, coupling with capacitor
  • EUT voltage per line: max. 200 V DC or 240 V peak
  • EUT current per line: max. 4 A cont. or 5 A for 5 min.
  • Coupling path 1: 40 Ω + 0.5 μF capacitor
  • Decoupling 1: 20 mH per line (protected 275 V max.)
  • Higher speed I/O: unsymmetrical, coupling with diode
  • EUT voltage per line: max. 24 V DC or peak
  • EUT current per line: max. 3 A cont. or 5 A for 5 min.
  • Coupling path 2: 40 Ω + 27 V diode
  • Decoupling 2: 560 Ω per line (protected 18 V max.)
  • Dimensions: 4 modules in carrying case: 33 x 27 x 17 cm
  • Weight: 7kg (all models and carrying case)

Equipment Specifications

Manufacturer:
EMC Partner
Standard:
IEC 61000-4-5
Application:
surge on 2 unsymmetrical lines
Test level surge:
max. 6 kV
EUT voltage per line:
max. 200 V DC or 240 V peak
EUT current per line:
max. 4 A cont. or 5 A for 5 min.