International (IEC/EN) Categories
International (IEC/EN) Test Equipment, Systems & Solutions
-
Radiated Immunity Test System for IEC 61000-4-20 TEM Waveguides
SKU: sku-393
Application/Test Type: IEC 61000-4-20Frequency Range: 30 to 1000 MHzMax Radiated Field Strength: Lowest field strength: 1 V/m at 600 mm septum height* Highest field strength: approx. 18 V/m at 600 mm septum height*Maximum Continuous Power: Lowest forward power: 15 dBm* Highest forward power: 41 dBm*Test Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20 -
Haefely ECOMPACT4 Precompliant EMC Impulse Generator
SKU: sku-320
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC/EN 61000-4-4Applications: EMC Precompliance Testing, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITTest Setup Support: Conducted Immunity/Susceptibility Test SetupMax EUT Current (w/ Built in CDN): 16 AmpsMax EUT Voltage (w/ Built in CDN): 60 VoltsPeak inrush current capability: >500 AmpsEFT/Burst Pulse Output Capability: 4.2 kVCombination/Wave Surge Output Capability: 4.2kVExternal Coupling: Data Lines (EFT & Surge), 3PH EUTDips, Interrupts & Variations: 0%, 40%, 70%, 80%Typically In Stock -
Used Schaffner NSG 2025-4 EFT / Burst Generator Built in Three Phase Coupler
SKU: sku-294
Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 0.1 kHz - 1,000 kHzBurst time: Rise Time: 5ns ±20% (50 W, 10 - 90%) Pulse Width: 50ns ±30% (50 W and 1 W), 100ns ±50% open circuitCoupling: Line to reference ground (IEC 1000-4-4), selected lines together to reference ground, all lines to reference ground (common mode)Mains & EUT Connections: HV Coax (Direct); L, N and PE via CouplerPhase synchronization: Asynchronous/synchronous 0 - 360° ±2°Polarity: Positive/NegativePulse amplitude: 200 Volts - 4.5 kV (20 Volt Steps)Repetition time: 100ms to 10sTest duration: 1 to 150 pulses (15ms burst duration as per IEC 61000-4-4 up to 10 kHz) -
Amplifier Research (AR) ATR80M6G Wide Band, High Gain Log Periodic Antenna
SKU: 2657
Max RF Input Power: 5,000 WattsAntenna Factor (1 Meter): 14 to 67 db/m (±1.5 dB)Application/Test Type: Radiated Immunity TestingDimensions: 132.1 x 20.32 x 97.8 cm (52 x 8.0 x 38.5 in)Frequency Range: 80 MHz - 6 GHzMax Radiated Field Strength: 1,000 V/mVSWR: 2.0:1 (Max: 3.0:1)$1,275.00Typically In Stock -
Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines
SKU: sku-222
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 ADimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBRF Connector: BNC 50 ΩRF Input Voltage: Less than 20 VoltsStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 10 dB ±1 dBVoltage Rating: 3 kV DC, 2 sec$790.00 -
AH Systems CPF-630 Current Monitoring Probe Calibration Fixture
SKU: sku-205
Weight: 9 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 10" x 7" x 6"Frequency Range: 20 Hz - 500 MHz -
AH Systems SAS-571 Broadband Double Ridge Horn Antenna
SKU: 4192
Weight: 3.5 lb.'s (1.59 kg)3dB Beamwidth (E-Field): 48°3dB Beamwidth (H-Field): 30°Antenna Factor (1 Meter): 22 to 44 dB/mAntennas: Double Ridge Guide Horn AntennaAperture: 5.5" x 9.6" (13.9cm x 24.4cm)Application/Test Type: FCC, MIL-STD, VDE and TEMPEST TestingConnector: N-Type, femaleDimensions: 11" x 5.6" x 9.6" (27.9cm x 14.2cm x 24.4cm)Frequency Range: 700 MHz - 18 GHzGain: 1.4 to 15 dBiImpedance: 50 OhmsMax Radiated Field Strength: 200 V/mMaximum Continuous Power: 300 WattsMounting Base: ¼ - 20 Thread, femaleVSWR: 1.6:1 (3.5:1 max)$3,780.00Typically In Stock -
EM Test (Lüthi) M1 CDN for Earth Conductor 250V AC / 1,000V DC
SKU: sku-103
Application/Test Type: Coupling/decoupling networks for Conducted immunity, mains AC power supply linesCurrent Rating: 16 Amps (Max)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4mm safety lab connectorRF Input Voltage: 30 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Rating: 250 V AC / 1,000 V DC -
Com-Power CDN-M125E Coupling Decoupling Network
SKU: sku-20
Weight: 5 lbs. 2.3 kgApplication/Test Type: Single conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Dimensions: 6 x 6 x 13 inches 15.2 x 15.2 x 33 cmFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)RF Input Voltage: 40 V (Max)Standards Met: IEC / EN 61000-4-6Voltage Division Factor: 9.5 dB +4 / -1Voltage Rating: 250 V AC / 350 V DC (Line to Ground) -
Rent Haefely PEFT 4010 Electrical Fast Transient EFT/Burst Generator for IEC 61000-4-4
SKU: 10246
Burst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Coupling: Built-in Single Phase 250 Volts AC / 110 Volts DC and 16 AmpsPulse amplitude: 0.10 - 4.5 kVApplications: Electrical Fast Transient ImmunityTest duration: Impulses per burst 1000 max Impulses per second 12000 max$550.00Typically In Stock -
Haefely ONYX 16 ESD Simulator Gun for IEC 61000-4-2
SKU: 0536
Air Discharge Voltage Range: 1 to 16 kV or 1 to 30 kVBattery: at least 16 hour battery lifeContact Discharge Voltage Range: 1 to 16 kV or 1 to 30 kVFrequency Capabilities: single/0.1/0.2/0.5/1/2/5/10/20 HzHolding Time: More than 5 secPolarity: positive & negativePre-Programmed IEC Levels: YesResolution: 100V stepsStandards Met: IEC/EN 61000-4-2, ISO 10605$295.00Ships Same Day -
IEC/EN 61000-4-X Test Rack for Conducted Immunity Certification
SKU: 11195
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-5, IEC 61000-4-4, IEC 61000-4-11, IEC/EN 61000-4-12Applications: Electrical Transient and Noise, Surge Immunity, Power FailuresTest Setup: Conducted Immunity/Susceptibility Test SetupMax EUT Power: 600 Voltas @ 100 AmpsPeak inrush current capability: 500 A (at 230 V)EFT/Burst Pulse Output Capability: 4.8 kVCombination/Wave Surge Output Capability: 4.4 kV (in 1 V steps)Generic Standards: IEC 61000-6-1, IEC 61000-6-2Inquire for Availability