CISPR Standards

(Showing 12 of 143)

CISPR standards are established, internationally accepted methods to test and comply products against EMC. Manufacturers will find these referenced in their product specific standard, with notes if any adjustments are to be made. The EMC Shop is well versed on CISPR Standards and supports customers to measure and evaluate their product in anticipation of a certificaition test. CISPR is for commercial electronics and automotive vehicles. 

Learn More

The EMC Shop stocks test equipment to test and pre-certify products to CISPR standards.

Show 12 24 36 48 96

CISPR Standards Categories

CISPR Standards Test Equipment, Systems & Solutions

  • AH Systems SAS-540 Biconical Antenna, 20 MHz to 330 MHz, up to 2 V/m

    SKU: sku-674

    Weight: 3.8 lb.'s (1.72 kg)
    Antennas: Biconical Antennas
    Application/Test Type: Radiated emissions and immunity
    Connector: N-type (female)
    Dimensions: Height: 29 in. (73.7 cm) Width: 52.5 in. (133.4 cm)
    Frequency Range: 20 MHz - 330 MHz
    Gain: -22 to 2.8 dBi
    Impedance: 50 Ohms nominal
    Maximum Continuous Power: 1 Watts
    Mounting Base: ABC-B (included)
    VSWR: 2.0:1
  • Com-Power LI-3P-216 LISN, 9 kHz to 30 MHz, 50/250 uH, 500 VAC

    SKU: 11665

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 16 Amperes
    Dimensions: 19.3” x 13.9” x 2.3"
    Frequency Range: 9 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    $5,795.00
    SHIPS IN 3-5 DAYS
  • Com-Power LI-3P-1100 150 kHz - 30 MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-600

    Weight: 71.5 lbs
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 100 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
  • Com-Power LI-3P-163 150kHz - 30MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-599

    Weight: 52.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 63 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
  • Com-Power LI-3P-116 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-597

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 16 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    CISPR 16-1-2: Yes
    DO-160F: Yes
    CISPR 22: Yes
    FCC: Yes
    ANSI C63.4: Yes
    $395.00 - $5,350.00
  • AH Systems SAS-545 1 GHz Biconical Antenna

    SKU: sku-573

    Weight: 1.6 lb.'s (725 g)
    Antennas: Biconical Antennas
    Application/Test Type: Radiated emissions and immunity
    Connector: N-type (female)
    Dimensions: Height: 15 in. (38.1 cm) Width: 14 1/4 in. (36.25 cm) Depth: 7 11/16 in. (19.5 cm)
    Frequency Range: 30 MHz - 1GHz
    Gain: -50 to 2.5 dBi
    Impedance: 50 Ohms nominal
    Maximum Continuous Power: 200 Watt
    Mounting Base: ABC-B Mounting Clamp with ¼ - 20 Thread, female
  • Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz

    SKU: sku-399

    Weight: 1.9 Lbs (0.86 kg)
    Application/Test Type: For coupling and decoupling of interference signals on screened lines
    Current Rating: 1.5 Amps
    Dimensions: 7.25 x 4.25 x 5.75 (inches)
    Frequency Range: 150 kHz to 230 MHz
    Mains & EUT Connections: BNC
    Standards Met: IEC/EN 61000-4-6
    Voltage Rating: 100 V
  • Used EMCO/ETS-Lindgren 3142 Biconical Antenna

    SKU: sku-303

    Impedance: 50 Ω
    Weight: approx. 4 kg
    Antenna Factor (1 Meter): 30 MHz: 12 dB/m; 60 MHz: 10 dB/m; 300 MHz: 14 dB/m; 500 MHz: 18 dB/m; 1000 MHz: 25 dB/m; 2000 MHz: 30 dB/m
    Antennas: Bilogical Antennas
    Application/Test Type: Precompliance RF Immunity & Emissions Testing
    Connector: N type female
    Dimensions: (L x W x H) 29.5" x 53.1" x 35.4"
    Frequency Range: 26 MHz to 2 GHz
    Impedance-2: 50 Ω
    Maximum Continuous Power: 300 Watts
    Standards Met: CISPR 11 CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 32, IEC 61000-4-3 ANSI C63.4 FCC-18 EN 55022
    VSWR: 2:1 average
  • Rent Solar 9247-50-TS-50-N LISN for CISPR 16-1, FCC Part 15, ANSI C63.4

    SKU: sku-302

    Application/Test Type: Power line conducted emissions tests
    Current Rating: 50 Amps
    Frequency Range: 10 kHz to 50 MHz
    Inductors: 50 µH (0.10 µF Coupling Capacitor)
    Mains & EUT Connections: Terminal Screw
    RF Connector: 50Ω N-type (female)
    Standards Met: FCC Part 15, CISPR 16-1, ANSI C63.4 (1992)
    Voltage Rating: 500 VAC (Line to Ground), 800 VDC