Combination wave pulse 1, 2/50 - 8/20 ÎĽs (Hybrid-Surge pulse):
Pulse conforms to IEC/EN 61000-4-5
Coupling:
Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
Polarity:
positive, negative, alternating
Pulse current (short circuit):
100 Amps to 2.1 kA
Pulse repetition:
up to 12 per minute
Pulse voltage (open circuit):
200 Volts to 4.2 kV
Standards Met:
IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2
Industries:
CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
Applications:
Immunity to Electrical Surges (Test Setup)
Manufacturer:
Haefely
Online Orders Ship Same Day

 

Availability:

Typically In Stock

SKU:
10574

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

  • Combination wave
    • Voltage: 1,2/50us
    • Current: 8/20us
  • Impulse voltage: 200V - 4.2kV
  • Impulse current: 100A - 2.1kA
  • Maximum impulse repetition rate 12 per minute
  • Positive, negative and user definable alternating polarity
  • Integrated CDN for 16A at 264Vac and 110Vdc
  • Impulse voltage, current and EUT current measurement
  • Test parameter ramp functions
  • Phase angle synchronization

 

About the Haefely PSURGE 4010:

The Haefely PSURGE 4010 is a cost effective solution for precompliance and troubleshooting DUT susceptibility in accordance to surge immunity test standards IEC 61000-4-5 and others. It's compact size allows for inexpensive shipping, its easy to use interface and automatic execution of test routines and sequences alllows for easy setup and quick testing.

Key Considerations

Manufacturer:
Haefely
Combination wave pulse 1, 2/50 - 8/20 ÎĽs (Hybrid-Surge pulse):
Pulse conforms to IEC/EN 61000-4-5
Coupling:
Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5
Polarity:
positive, negative, alternating
Pulse current (short circuit):
100 Amps to 2.1 kA
Pulse repetition:
up to 12 per minute
Pulse voltage (open circuit):
200 Volts to 4.2 kV
Standards Met:
IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2
Industries:
CE Marking, Medical Devices, Industrial Machinery, Electronics & IT
Applications:
Immunity to Electrical Surges (Test Setup)