Categories
Test Equipment, Systems & Solutions
-
EM Test (Lüthi) CDN S1 for 50 kHz to 230 MHz
SKU: sku-400
Weight: 2.0 lbsApplication/Test Type: Coupling/decoupling networks for Conducted immunity, screened lines (coaxial cable)Current Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 4.25 inchesFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC / EN 61000-4-6Voltage Rating: 100 V -
Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-399
Weight: 1.9 Lbs (0.86 kg)Application/Test Type: For coupling and decoupling of interference signals on screened linesCurrent Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Dressler AF4 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-398
Weight: 3.3 Lbs (1.5 kg)Current Rating: 2 AmpsFrequency Range: 150 kHz to 230 MHzRF Connector: BNCStandards Met: IEC/EN 61000-4-6Voltage Rating: 100 V -
Radiated Immunity Test System for IEC 61000-4-20 TEM Waveguides
SKU: 10393
Application/Test Type: Radiated Susceptibility TestingFrequency Range: 30 to 1000 MHzMax Radiated Field Strength: Lowest field strength: 1 V/m at 600 mm septum height* Highest field strength: approx. 18 V/m at 600 mm septum height*Maximum Continuous Power: Lowest forward power: 15 dBm* Highest forward power: 41 dBm*Test Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20 -
AH Systems BCP-614 Probe to Measure Conducted RF Currents, 10 KHz - 300 MHz
SKU: sku-379
Weight: 5.5 lb.'s (2.5 Kg)Aperture: 2.6" (66 mm)Application/Test Type: Conducted and Radiated Susceptibility TestingCurrent Rating: 350 AmpsDimensions: 4.27" (134 mm)Frequency Range: 10 KHz - 300 MHzRF Connector: N-Type (female)Standards Met: IEC 61000-4-6; IEC 60601-1-2, Mil-STD-461 CS 114Transfer Impedance: -25 to 1 (dBohm)$195.00Typically In Stock -
Com-Power AB-900A Biconical Antenna 25 MHz to 300 MHz
SKU: 0349
Weight: 5 lbs. [2.3 kg]Antennas: Biconical AntennasApplication/Test Type: Radiated emissions and immunityConnector: N-type (female)Dimensions: 51.5” x 20.2” x 27.2” [130.8 x 51.3 x 69.1 cm]Frequency Range: 25 MHz to 300 MHzGain: -15 to 3 (average: -2.9 ) dBi (Isotropic)Impedance: 50 Ohms nominalMaximum Continuous Power: 50 WattsMounting Base: sold separateVSWR: 1.2 to 34 (average: 8.1) :1Typically In Stock -
Teseq CDN 118-T4 Coupling Decoupling Network set for 1.2/50 µs and 10/700 µs Surge Pulses on 1 or 2 twisted pairs
SKU: 30093
Application/Test Type: 1.2/50 μs (2 ohms) and 10/700 μs (15 ohms) pulse up to 6.6 kV line to ground, 3 kV line to line (Pulse frequency: 3 per minute)Current Rating: 0.5 AmpsDecoupling chokes 1 kHz: 20 mH nominalDimensions: 335 x 232 x 180mmMains & EUT Connections: 4 mm safety banana; Fischer 103Ohmic resistance per path: 3 ΩSeries resistor: in relation to the selected pulse coupling networkTransmission 3 dB BW: 250 kHzVoltage Rating: 250 Volts AC/DCInquire for Lead Time -
EM Test UCS 500M4 Transient Simulator w/ Burst/EFT
SKU: 34111
Applications: EFT/Burst Testing, Dips Interrupts & Variations, EMC Precompliance TestingStandards Met: IEC 61000-4-4, IEC 61000-4-11Max EUT AC Voltage (w/ Built in CDN): 250 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 250 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsEFT/Burst Pulse Output Capability: 4.4 kVDips & Interrupts: 16 – 500 HzInquire for Availability -
AH Systems SAS-521-2 Bilog Antenna, 25 MHz - 2 GHz
SKU: sku-340
Impedance: 50 OhmWeight: approx. 4.4 lbs (2 kg)Antenna Factor (1 Meter): 7 to 30 dB/mAntennas: Bilogical AntennasApplication/Test Type: RF EMC immunity testing, Improved high frequency gainConnector: N type femaleDimensions: 22.2 in. (56.4 cm) x 38.5 in (97.8 cm) x 39 in (99.1 cm)Frequency Range: 25 MHz - 2000 MHzGain: -28 to 7 dBiImpedance-2: 50 OhmsMaximum Continuous Power: 1000 WattsStandards Met: IEC/EN 61000-4-3, CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 24, CISPR 32, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60533, IEC 60601-1-2, IEC 61326, ISO 11452-2, -
-
3ctest 405T8A1 Surge CDN For Unshielded Data Lines
SKU: sku-332
Application/Test Type: Test high-speed communication lines against lightening surge as per picture 10 in IEC/EN61000-4-5 edition 3Coupling: Common mode (line to ground)l 90V gas discharging tubeCurrent Rating: Max 1 AImpedance: 200Ω ±5%Input: 1.2/50us, 10/700usMains & EUT Connections: RJ45 femaleStandards Met: IEC 61000-4-5 Ed. 3Test Voltage: 6kV (10kV, customized)Voltage Rating: 90 VDCTypically In Stock -
3ctest CWS 600 6kV Surge Simulator for IEC 61000-4-5
SKU: 11331
New Systems: Inquire to purchase a new unitStandards Met: UL 1449, IEC/EN 61000-4-5, IEC/ISO 60601-1-2Coupling: Single Phase Built in, 16A, 250VAC, 120VDCApplications: EMC Surge, CE MarkingMains & EUT Connections: 4mm banana plugPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-3kA ±10%Pulse repetition: 1-999Pulse voltage (open circuit): 0.2kV - 6kV ±10%$1,490.00In stock