Categories
Test Equipment, Systems & Solutions
-
Used Empower 800 MHz - 4.2 GHz, 13 Watt High Power RF Amplifier
SKU: sku-843
Weight: 30 LBsDimensions: 19 x 3.5 x 18 in.Frequency Range: 800 - 4200 MHzGain: 42 dB minImpedance: 50 ohms nominalRF Connector: Type N female -
Rent ETS-Lindgren 5402 GTEM Test Cell for Small DUT
SKU: 10839
Features: Ships fully assembled, easy unpack and setupApplications: Radiated Emissions, RF/Radiated Susceptibility TestingMax DUT Size: 8" x 8" x 6"Test Standards: FCC Part 15, IEC 61000-4-3$1,750.00 - $1,755.00In Stock -
ETS-Lindgren 5405 RF Emissions and Immunity Test Cell
SKU: sku-838
Max EUT Size: 7" by 9" by 13"Frequency Range: 9 kHz to 5 GHz (RE), DC - 20 GHz (RI)Max Input Power (CW): 250 WattsApplications:Radiated Immunity, Radiated Emissions Dimensions (Footprint): 5.5' x 10' x 5.25'Typically In Stock -
Ground Reference Plane for EMC/EMI Testing
SKU: sku-833
Material: Aluminum (Copper upon request)Dimensions: 9' by 6'In Stock -
Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6
SKU: 10828
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$1,190.00 -
Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network
SKU: 10827
Associated Equipment: RF Conducted Immunity Test SystemsApplication/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 16 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: 4 mm bananaRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts (Max)Standards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$195.00 - $495.00Typically In Stock -
Fischer F-35A 100 Hz – 108 MHz Current Monitor Probe
SKU: 1819
Aperture: 32 mmConnector type: Type-NDimensions: Internal diameter: 32 mm External diameter: 98 mm Height: 38 mmFrequency range: 100 Hz – 100 MHzGeneral Data: Technical DetailsHigh frequency 3dB cut-off: 108 MHzLow frequency 3dB cut-off: 100 HzMaximum peak current: 100 AmpsOutput resistance: 50 OhmsProbes: Current monitoring$195.00 - $395.00In Stock -
Teseq NSG 4070C-80 Integrated Signal Generator, 4 kHz to 1 GHz, 80 W Integrated Class A Power Amplifier
SKU: sku-809
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 40VrmsBCI Test Levels (w/ built-in amplifier): 8VrmsFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzTypically In Stock -
Keysight/Agilent E4419B EPM Series Dual-Channel Power Meter
SKU: 0807
Weight: 4.1 kg (9.0 lb) netDimensions: 212.6 mm W x 88.5 mm H x 348.3 mm D (8.5 in x 3.5 in x 13.7 in)General Data: Technical DetailsRF Field Probe Frequency Range: 9 kHz to 110 GHzRF Field Probe Power Measurement Range: –70 dBm to +44 dBm (100 pW to 25 W), sensor dependentSupply Voltage: Battery$250.00 - $1,500.00 -
Amplifier Research PM2003 Power Meter, 3 Channel, 10 kHz - 40 GHz, -70dBm to +44dBm
SKU: sku-805
Weight: 7 lbs (3.2 kg)Dimensions: 8.25 in (21.0 cm) wide, 3.5 in (8.9 cm) high, 13.25 in (33.7 cm) deepRF Field Probe Connector: Inputs: Rear panel HEAD connectors and rear panel IEEE-488 connector standard. Outputs: Rear panel PWR/REF connector, 0dBm, 50 MHz. Rear panel RECORDER BNC connector, 0 to 10V into 1mW.RF Field Probe Frequency Range: 10 kHz-40 GHz, power head dependentRF Field Probe Maximum Input Power: May be operated into 1kW or 1V fsRF Field Probe Power Measurement Range: -70dBm to +44dBm, power head dependent -
Noiseken LSS-15AX Series Lightning Surge Simulator up to 15kV
SKU: sku-800
Weight: 200 kg.Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: AC/DC lines CDN, and Telecom lines CDNDimensions: 555 X 1250 X 790 mmImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 15kV/7500APulse repetition: 20 secPulse voltage (open circuit): 15kV/7500AStandards Met: IEC 61000-4-5Inquire for Availability -
Schloder M Type CDN's for Disturbance Signals to Unscreened Supply Lines (mains) AC + DC up to 1000V, 100A
SKU: sku-791
Application/Test Type: unscreened supply lines (mains) AC + DCCurrent Rating: 16A / 32A / 63 A / 100 ADimensions: 160 x 84,5 x 240mm or 200 x 122,5 x 400mm depending on modelFrequency Range: 150 kHz to 230 MHzMains & EUT Connections: banana socketsRF Connector: 50 Ω BNC (Female)Standards Met: IEC / EN 61000-4-6Voltage Rating: up to 250 VAC / 400 VDC