Boonton 59318 500 MHz - 18 GHz Wideband Peak Power Sensor
SKU: sku-915
Rise Time: Slow: 350 kHzDynamic Range: -24 to +20 dBm -34 to +20 dBm -10 to +20 dBmFrequency Range: 500 MHz - 18 GHzImpedance: 50 ohmOverload: 1 W for 1µs 200 mWRise time: Fast: 50 MHz typical -
Amplifier Research FP7018 3 MHz –18 GHz, 1000 V/m Electric Field Probe
SKU: sku-914
Dimensions: 420 x 85 x 65 mm including base and probe head.Weight: 350g ApproximatelyBattery: Standard recharger included, 3 hour charge time.Damage Level: 1600 V/m CW and 16,000 V/m peakData Transfer Rate: 30 samples per secondDimensions-2: 420 x 85 x 65 mmOperating Temperature: 0 to 50°CPower Requirements: 2 built-in NiMH batteries, size AA, Rechargeable, changed by operator, 40 hours operating life per charge.Probe Head Diameter: 65mmProbe Sampling Rate: 60Hz, 50Hz, 5 Hz- user selectableRanges: Single continuous rangeSensitivity: 0.6–1000 V/m -
Amplifier Research FM5004 E and H Field Monitor
SKU: sku-912
Display Interface: IEEE-488 Interface and RS-232 InterfaceFrequency Range: 10 kHz - 40 GHzInput: Up to 4 independent ProbesOverload: Probe dependentSensitivity: 0.15-3000 V/m; 15.0 mA/m - 30 A/m -
ETS-lindgren 3148 200MHz-2GHz Log Periodic Dipole Array Antenna
SKU: 2514
Weight: 2.0 kg (4.5 lb)Connector: Type N femaleFrequency Range: 200 MHz – 2 GHzMaximum Continuous Power: 1 kWVSWR: 1.2:1 average 2.0:1 maximumInquire for Availability -
Com-Power LI-3P-2100 9kHz - 30MHz Three Phase LISN for CISPR / ANSI
SKU: sku-895
Frequency Range: 9 kHz – 30 MHzInductors: 50Ω, 50/250 μH +5Ω, (4) Conductor NetworkMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-3P-232 Three Phase LISN for CISPR / ANSI
SKU: sku-893
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent rating: 32 AmperesDimensions: 19.3” x 13.9” x 2.3″Frequency Range: 9 kHz – 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-150C Line Impedance Stabilization Network
SKU: sku-890
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 50 Amps (AC), 35 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 5 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LIN-120C Line Impedance Stabilization Network
SKU: sku-889
Weight: 10 lbs (4.5 kg)Application/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amps AC (rms) , 14 Amps DCDimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)Frequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUTRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2, ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Narda Broadband E-Field Meter Kit, 100 kHz - 50 GHz
SKU: sku-885
Weight: 10.6 oz.Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: NiMH rechargeable batteries 4 x AA size (Mignon), 2500 mAhDimensions: 1.5 x 2.0 x 8 inchesFrequency Range: 100 kHz - 60 GHzOperation Time: 20 hours (backlight off, no GPS) 12 hours (permanent backlight, no GPS) 10 hours (GPS receiver connected, no backlight)Recharging Time: 2 hoursStandards Met: IEC 61000-4-3$595.00Typically In Stock -
Com-Power LI-125C 150 kHz to 30 MHz Line Impedance Stabilization Network Pair
SKU: sku-881
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 25 Amps (AC), 17 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Keysight E9300A Average RF Power Sensor
SKU: 6307
Frequency Range: 10 MHz to 18 GHzRF Power Range: -60 to +20 dBmMax Average Power: 320 mW +25 dBmPeak Envelope Power: 2 Watts +33 dBm (< 10 μsec)In Stock -
DAMS 7000 40 GHz Antenna Positioner/Turntable System
SKU: 31879
Frequency Range: DC to 40 GHzMeasurement Types: 2D, 3D, OTA, Far Field, Phase Center, SphericalResolution: up to 0.0625º steps azimuth and 0.10º steps elevationWeight Capacity: 5, 10 or 25 Pounds (Spherical Mount Dependent)Software: DAMS Antenna Measurement StudioInquire for Lead Time