Categories
-
Agilent N5181A Analog Signal Generator
SKU: 8183
Frequency Range: 100 kHz - 6 GHzOutput Power: +23 dBm output power @ 1 GHzPhase Noise: -121 dBc/Hz at 1 GHz and 20 kHz offsetModulation: AM, FM, Pulse, PhaseTypical Configuration: 006, 012 ,099, 1E1, 1EA, 1EM, 1EQ, 1ER, 506, UK6, UNT, UNU, UNZ, 320, ALB$39.00 - $495.00In Stock -
Narda FieldMan 0 Hz to 90 GHz All-in-One Electromagnetic Field Meter
SKU: 12955
Frequency Range: 0 Hz/1 Hz/100 kHz to 90 GHzLogging Info: Temperature, Humidity, Air Preassure, Geolocation, Distance to GroundElectric Field Units: V/m, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Magnetic Field Units: A/m, Tesla, Gauss, mW/cm2 , W/m2 , % of standard (depending on the connected probe)Compliance Standards: 2013/35/EU, IEC/EN 62311, ICNIRP 1998, ICNIRP 2010, IEC/EN 62233, GB-8702-2014, EMFV 2016$495.00 - $1,850.00Typically In Stock -
EFT4-4 Fast Transient Burst Generator
SKU: 12174
EFT/Burst Pulse Output Capability: 100 Volts to 5 kV (10V steps)Max EUT Voltage (w/ Built in CDN): 230 Volts AC (110 VDC)Max EUT Current (w/ Built in CDN): 16 Amps (8 ADC)Programmability: Burst duration, burst period, burst frequency, pulse amplitude, polarity, number of pulses per second, max number of pulses burst,Pre-programmed: Test levels 1 - 4 of the IEC/EN 61000-4-4 standardIn Stock -
Amplifier Research 1000W1000G RF Amplifier 80MHz - 1000MHz, 1000 Watts CW
SKU: sku-2173
Max Frequency: 1 GHzMin Frequency: 80 MHzOutput Power: 1000 WattsApplications: Radiated Immunity, Automotive, Medical, Military and AerospaceStandards: IEC 61000-4-3, ISO 11451-2, MIL-STD 461, DO-160RENTAL ONLY -
RFPM1G-1000 Digital Power Meter with Directional Coupler
SKU: 4044
Frequency Range: 20 MHz to 1 GHzRF Power Rating: 1000 WApplications: Radiated Immunity, RF Conducted ImmunityIn Stock -
Wavecontrol SMP2 Broadband Field Strength Meter
SKU: 7056
Weight: 10.6 oz.Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: NiMH rechargeable batteries 4 x AA size (Mignon), 2500 mAhDimensions: 1.5 x 2.0 x 8 inchesFrequency Range: 100 kHz - 60 GHzIN STOCK -
Amplifier Research FL8040 Laser-Powered E-Field Probe Kit, 20 MHz – 40 GHz, CW & Pulse
SKU: 12061
Application/Test Type: Pulse Measurements & E-Field Characterization for Radiated Susceptibility TestingField Strength Range: 0.5 – 800 V/mResolution: 0.01 V/mFrequency Range: 20 MHz – 40 GHzStandards Met: MIL-STD-461 RS103, DO-160Typically In Stock -
Component Level EFT/Burst Immunity Test Setup
SKU: 30044
Bandwidth: DC to 500 kHzSampling Rate: 3 MspsResolution: 12 bitApplications: Burst/EFT Testing, EMC Precompliance TestingTest Standards: 61000-4-4In Stock -
Radiated Emissions Measurement System
SKU: 12013
Technical Support: FCC and iNarte TechniciansTest Setup: Quick Start Guide ProvidedShipping: Same Day, Larger Systems go FreightApplications: EMC Precompliance Testing, Radiated EmissionsFrequency Ranges: 2 Hz - 44 GHz$795.00 - $3,795.00Usually ships in 24 hours. -
3 Phase Harmonics & Flicker Test System IEC 61000-3-11 and 3-12
SKU: 11918
Standards Met: IEC 61000-3-11, IEC 61000-3-12, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-7, IEC 60601-1-2 and moreApplications: Flicker and Harmonics TestingCurrent Handling: 32 Amps per phaseInquire for Availability -
PA40G10M Millimeter-Wave Low Noise Amplifier
SKU: 1888
Max Frequency: 40 GHzMin Frequency: 10 MHzOutput Power: +18 dBm (P1dB)Gain: 40 dB typicalMax RF Input Power: +6 dBm @ 1 dB compression$495.00 - $6,975.00IN STOCK -
Amplifier Research FM7004 Electric Field Monitor
SKU: 11913
Display Interface: IEEE-488 Interface and RS-232 InterfaceFrequency Range: 5 kHz - 60 GHz (probe dependent)Input: Up to 4 independent ProbesOperating Temperature: 0 °C - 40 °C (50 °F - 104 °F) @ 5% - 95% RH non-condensingOverload: Probe dependentTypically In Stock