Categories
Test Equipment, Systems & Solutions
-
EM Test ACC Capacitive Coupling Clamp for ISO 7637 Automotive Testing
SKU: sku-635
Weight: 11.5 kgApplication/Test Type: Electrical Fast Transients for automotive applicationsCable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1250 mm x 300 mm x 93 mm, L x W x HRF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: ISO 7637Voltage Rating: up to 1.0 kVInquire for availability -
3ctest CCC100 EFT/Burst Coupling Clamp for IEC/EN 61000-4-4
SKU: 10621
Application/Test Type: Electrical Fast Transients on Data Lines (EFT Burst)Cable Diameter: up to 40 mm (1.57 in)Coupling Length: 1 m (39.4 in)Dimensions: 1040x140x110mmEFT Coupling Clamps: as per IEC 61000-4-4RF Connector: High voltage connector,coaxial. GND connection 4 mm plug, bananaStandards Met: IEC/EN 61000-4-4Voltage Rating: up to 5.5kv4 to 6 Weeks -
Haefely PSURGE 4010 Combination Wave Generator
SKU: 10574
Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Internal Single Phase/16 Amps at 264 VAC and 110 VDC -(expandable to 3-Phase with external module); 18uF and 9uF+10 Ω acc. to IEC 61000-4-5Polarity: positive, negative, alternatingPulse current (short circuit): 100 Amps to 2.1 kAPulse repetition: up to 12 per minutePulse voltage (open circuit): 200 Volts to 4.2 kVStandards Met: IEC 61000-4-5, EN 61000-6-1, EN 61000-6-2Industries: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITApplications: Immunity to Electrical Surges (Test Setup)Typically In Stock -
Com-Power AM-741R Active Monopole Antenna with RAI-100, 9 kHz - 60 MHz
SKU: AM-741R, RAI-100
Weight: 9.5 lbs. [4.3 kg]Antenna Factor (1 Meter): ±0.5 dBAntennas: Monopole AntennasApplication/Test Type: radiated emissions measurements, typically below 30 MHz.Connector: BNC (female)Frequency Range: 9 kHz to 30 MHz (useable to 60 MHz)Gain: See Image ThumbnailImpedance: 50 OhmsMounting Base: 1/4" 20 threadStandards Met: Mil-STD 461,DO-160$299.99Typically In Stock -
Com-Power CGC-255E Comb Generator 50 kHz - 400 MHz in 50 kHz/250 kHz steps
SKU: 11431
Weight: 1 lbs / 0.5 kgAC Power Adapter: 6 VDC, 500 mA / 110VAC 60 Hz or 230 VAC 50 HzApplication/Test Type: Reference Signal Source for LISN verificationBattery: 6V NiMH, 1 AhDimensions: 5 x 2.2 x 2.2 inches / 13.2 x 5.9 x 5.9 cmFrequency Range: 50 kHz to 400 MHz in 50 kHz or 250 kHz stepsMains & EUT Connections: LISN Interface Plug NEMA 15-P typeOperation Time: 18 Hours Typical With Fully Charged BatteryInquire for Availability -
Haefely AXOS 8 7kV Surge & EFT Generator
SKU: 10405
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsTransient EMC Standards: IEC/EN 61000-4-4, IEC/EN 61000-4-5Power Fail EMC Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Max EUT AC Voltage (w/ Built in CDN): 264 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsPeak inrush current capability: 500 A (at 230 V)External Coupling: Data Lines (EFT & Surge), 3PH EUTOutputs: 4 mm banana socketInquire for Availability -
Narda PMM COND-IS/10 RF Conductive Immunity Test System
SKU: 11334
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 10VrmsBCI Test Levels (w/ built-in amplifier): 3VFrequency Range (w/ built-in amplifier): 150 kHz - 230 MHzTypically In Stock -
Thermo Keytek ECAT Transient Generator System
SKU: 11321
Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.Pulse repetition: 1 shot/9 secondsPulse voltage (open circuit): 200V - 6.6kV ± 10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864In Stock -
Rent Rohde & Schwarz ESU40 EMI Test Receiver for CISPR and MIL-STD Testing
SKU: 30082
Frequency Range: 20 Hz to 40 GHz (DC coupled), 10 MHz to 40 GHz (AC coupled)Frequency Resolution: 0.01 HzFrequency Counter Resolution: 0.1 Hz to 10 kHzTest Standards: CISPR 16-1-1, MIL-STD-461Applications: Conducted Emissions, Radiated EmissionsInquire for Lead Time -
Teseq LNA 6000 Low Noise Amplifier 1 MHz to 3 GHz
SKU: sku-80
Weight: approx. 127 grams (0.3 Lb's)Application/Test Type: Increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments.Dimensions: 28 mm x 95 mm x 27 mmFrequency Range: 1 MHz to 3 GHz (nominal range) 200 kHz to 4 GHz (utilizable range)Gain: 12.5 dB (±0.3 dB flatness)Input: 0 dBm (107 dBμV)Maximum Continuous Power: 12.5 dBm @ 1 dB compressionRF Connector: IN: N-type (f); OUT: N-type (m)Inquire for Availability -
Pearson 411 Surge Current Monitor up to 5kA Peak Current, 1Hz to 20 MHz
SKU: P-411
AC Current Handling (DC-400Hz): 50 AmpsRF Current Handling (CW/Pulse): 50/5,000 AmpsStyle: Fixed WindowDiameter: 0.5"Transfer Impedance: 1 OhmTest Standards: IEC 61000-4-5Frequency Range: 1 Hz to 20 MHzSEVERAL IN STOCK -
Inquire for Lead Time