3ctest CST 10150DH Pulsed Sinusoidal Disturbances Immunity

Condition:
New
Frequency Range:
9 kHz ~ 6 GHz
Test Electrical Level:
-50 dBm ~ +20 dBm
Accuracy:
±0.2 dB
Input Interface:
N (female)
VSWR:
<1.1:1
Max. Power:
500 W
Dimension:
19" / 4U
Weight:
Approx. 15 kg
Ambient Temperature:
15℃~35℃
Relative Humidity:
45%~75%
Atmospheric Pressure:
86 kPa~106 kPa
Manufacturer:
3ctest
Online Orders Ship Same Day

 

Downloads

Datasheet

 

Availability:

Typically In Stock

SKU:
11422

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The CST 10150DH is designed as per ISO 7637-4 and adopts all-in-one design, which integrate signal generator, RF power amplifier and RF power meter and each of them can be used independently. External power amplifier is optional as well as. Its frequency ranges from 100 kHz to 100 MHz. The CST 10150DH is controlled by PC software, so calibration and test can be conducted automatically, which greatly improves the test efficiency and system extendibility. The generated test result can be saved, printed or shared internally.

Features:

  • Integrate signal generator, RF power amplifier and RF power meter in one unit;
  • The creation of test templates makes software operation easy;
  • USB interface for PC remote control;

Application Areas:

  • Automotive
  • Military
  • Electrical Power
  • Aviation
  • Automation Equipment

 

Technical Parameters (Signal Generator)

Model No.

CST 10150DH

Standard

ISO 7637-4 Pulse A

Frequency Range

1 μHz~100 MHz

Frequency Resolution

1 μHz

Frequency Stability over Temp.

±1 ppm+10 pHz 

18℃~28℃

Harmonics

DC~10MHz (including 10 MHz): <-55dBc

10MHz~20MHz (including 20 MHz): <-50dBc

20MHz~40MHz (including 40 MHz):<-40dBc

>40MHz<-35dBc

Non-harmonics

10MHz<-60dBc

>10MHz<-60dBc+6dB/Octave

Output Power

10MHz1.0mVpp~10Vpp

30MHz1.0mVpp~5.0Vpp

60MHz1.0mVpp~2.5Vpp

>60MHz1.0mVpp~1Vpp

Power Precision

Typical1kHz sinusoidal, 0V offset, >10mVppautomatic

± (1% of setting value) ±5mV

Power Meter Resolution

0.1 mVpp

Amplitude ModulationAM

Modulation depth: 0~120;

Modulated rate: 2 mHz ~1 MHz

Frequency ModulationFM

Modulated rate: 2 mHz ~1 MHz

Phase ModulationФM

Phase modulation :0°~360°;

Modulated rate: 2 mHz ~1 MHz

Pulse Repetition

1 μs ~ 500 s

Pulse Width

0 ns~100 s

Output Interface

N (female)

VSWR

<1.5:1

Technical Parameters (Power Meter)

Frequency Range

9 kHz ~ 6 GHz

Test Electrical Level

-50 dBm ~ +20 dBm

Accuracy

±0.2 dB

Input Interface

N (female)

VSWR

<1.1:1

Technical Parameters (Power Amplifier)

Frequency Range

100 kHz~230 MHz

Gain

51.7 dB±1 dB (150 W)

1dB Gain

51.3 dB±1 dB (135 W)

VSWR

<1.5:1

Output Impedance

50 Ω

Output Interface

N (female)

General Parameters

Working Power

AC 110 V/220 V ±10%50 Hz /  60 Hz±5% AC 220 V 50 Hz in mainland China

Max. Power

500 W

Dimension

19" / 4U

Weight

Approx. 15 kg

Ambient Temperature

15~35

Relative Humidity

45%~75%

Atmospheric Pressure

86 kPa~106 kPa

Key Considerations

Manufacturer:
3ctest
Frequency Range:
9 kHz ~ 6 GHz
Test Electrical Level:
-50 dBm ~ +20 dBm
Accuracy:
±0.2 dB
Input Interface:
N (female)
VSWR:
Max. Power:
500 W
Dimension:
19" / 4U
Weight:
Approx. 15 kg
Ambient Temperature:
15℃~35℃
Relative Humidity:
45%~75%
Atmospheric Pressure:
86 kPa~106 kPa

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.