EFP18G-P Pulsed Isotropic Electric Field Probe 100 MHz-18 GHz Details
The EFP18G-P Isotropic Electric Field Probe operates in 100 MHz to 18 GHz covering test requirements requirements of MIL-STD-461 and automotive EMC GM and Ford specifications. The Broadband isotropic electric field probe measures pulsed RF field produced by the microwave radars. It has fast capability to measure the field strength of RF bursts/pulses as short as a microsecond.
- Diode based 3-Axial isotropic sensor.
- Field strength range: 70-1400 V/m.
- Pulse duty: 0.01% to 100%.
- Pulse repetition period: 0.1-10 msec.
- Frequency of pulse repetition: 100-10000 Hz.
- Shortest pulse width: 1 us.
- Longest pulse repetition period: 10 ms.
- Pulse amplitude measurement variation for fields
- >200 V/m over the range of pulse width (from 1 uSto 100% duty) and period (0.1-10 msec.): <1 dB.
- Pulse amplitude measurement variation for fields
- >70 V/m over the range of pulse width (from 4 uS to 100% duty) and period (0.1-10 msec.): <1 dB.
- Linearity: +/- 0.5 dB.
- Frequency response (no corr. factors):
- 100 MHz-6 GHz (+/- 3 dB), 6-18 GHz (+/- 4 dB).
- Frequency response (with corr. factors): +/- 1.5 dB.
- Rotational isotropicity: <1 dB.
- Rechargeable battery operating time: >60 hrs.
- Temperature: 5-40 °C,
- Humidity (non-condensing): RH 10-90%.
- Temperature error: 0.05 dB/°C.
- UK NPL or NIST traceable calibration.
- Probe size (LxD): 12.0"x2.25" (310x58 mm).
- Power Unit: (LxWxD): 4x2.3x1.3 (100x58x33 mm).
- Weight (probe and power unit): 0.5 lb, 230 g.
- Operates with RFP-05 meter
**Now Available - Accredited Field Probe Calibrations**