EFT4-4 Fast Transient Burst Generator
SKU: 12174
EFT/Burst Pulse Output Capability: 100 Volts to 5 kV (10V steps)Max EUT Voltage (w/ Built in CDN): 230 Volts AC (110 VDC)Max EUT Current (w/ Built in CDN): 16 Amps (8 ADC)Programmability: Burst duration, burst period, burst frequency, pulse amplitude, polarity, number of pulses per second, max number of pulses burst,Pre-programmed: Test levels 1 - 4 of the IEC/EN 61000-4-4 standardPower Input: 100-240 VACApplication: EFT TestingIn Stock -
ELMAG20A Air Gap Electromagnet up to 2.2 Tesla
SKU: 72333
Number of turns (per Coil): 2000Resistance at Room Temperature: 14 ΩMaximum Permissible Resistance During Use: 16 ΩMaximum Coil Current: 20 A 1 min, 15 A 3 min, 10A 6 min, 5 A >20 minAir Gap Between the Poles: 0...95 mmMaximum Magnetic Flux Density: > 2.2 TCoil diameter: 335 mmPole Diameter at EuT: 30 mmPole Diameter: 75 mmMechanical Dimensions Base Plate: 380 x 238 x 22 mmTotal Height: 410 mmPole Height Above Base Plate: 182.5 mmTerminals: 4 mm female with universal wire fixtureInductance (pair of coils): 1.89 H / 10 Hz, 1.085 H / 20 Hz, 0.55 H / 50 Hz, 0.4 H / 100 HzDC Power Supply for Serial Coil Operation: 250 V / 20ARemanent Flux Density: typ. 5-8 mTWeight: 118 kg$2,450.00 - $21,950.00Lead Time: ~ 8 Weeks -
EMC/RF Shielded Tent Enclosure - RFT Series
SKU: 12035
Attenuation: 90 dB typicalFrequency Range: (150 kHz) 30 MHz - 18 GHzApplications: EMC Precompliance Testing, Radiated Emissions, Radiated ImmunityStandard Options: Lights and VentEnclosure Size: up to 10ft x 20ft 10ftDoor Size: 70in x 40inFrame Type: Portable and Heavy DutyFeedthroughs: 120 VAC, N(f), BNC(f), SMA(f), SleeveMost Sizes In Stock -
EMI-AK7G Antenna Kit Radiated Emissions Measurements
SKU: 10517
Frequency Range: 20 Hz - 7 GHzApplications: EMC Precompliance Testing, Radiated Emissions, TEMPEST TestingTest Standards: FCC Part 15, MIL-STD-461, IEC 61000-6-3, IEC 61000-6-4Typically in Stock -
EPT-0.8 EMC Plastic Table
SKU: 666541
Dimensions: 31.4 in/0.8 m (D) x 31.4 in/0.8 m (H)Load capability: Up to 220 LbsMaterial structure: RohacellDielectric constant e at 1 MHz: 1.05Material table top (removable) with a grid of 100 mm x 100 mm (3.9x 3.9 in): Pertinax t = 2 mm (0.07 in)Temperature working range: 10°C – 35°CTotal weight: 15.5 lbs (7 kg)Standards Met: CISPR 25, MIL-STD-461Applications: EV and Automotive, Conducted EmissionsAdditional Applications: Radiated Emissions, Radiated ImmunityInquire for Availability -
EPT-1.2 EMC Plastic Table
SKU: 11445
Table top diameter: 47.3 in/1.2 m (D) x 31.5 in/0.8 m (H)Load capability: Up to 220 LbsMaterial structure: StyrodurDielectric constant e at 1 MHz: 1.2Material table top (removable) with a grid of 100 mm x 100 mm (3.9x 3.9 in): Pertinax t = 2 mm (0.07 in)Temperature working range: 0°C – 35°CTotal weight: 26.5 lbs (12 kg)Standards Met: CISPR 25, MIL-STD-461Applications: EV and Automotive, Conducted EmissionsAdditional Applications: Radiated Emissions, Radiated ImmunityIn Stock -
ESA EMI Spectrum Analyzer for Precompliance Testing
SKU: 112048
Applications: Conducted Emissions, Radiated Emissions, Spectrum Analyzers for EMCPre-programmed Test Limits: FCC Part 15, CISPR 22, and moreMax Frequency: 1 GHz, 3 GHz or 7.5 GHzMin Frequency: 9 kHzSweep/Test Speed: SlowAmplitude Accuracy: < 0.7 dBResolution Bandwidth: 1 Hz to 3 MHz$195.00 - $995.00IN STOCK -
$197.00
-
GRC Series Ground Cable w/ 470k Ohm Resistors for ESD Voltage Bleeding
SKU: 30180
Ideal for: voltage bleeding to Ground Plane during Indirect ESD Immunity TestingCompliant to: IEC 61000-4-2, ISO 10605, DO-160, Mil-STD CS118 and more.Cable rated to: 40kV High Voltage Cable (150 degrees C)Length: 1.5 Meters (5 Feet)Resistance: HV Precision Resistors (1% tolerance)$198.99 - $298.99In Stock -
GTEM 250 Electromagnetic Transverse Waveguide Cell
SKU: sku-677
Max EUT Size: 8" x 8" x 6"Frequency Range: DC - 20 GHzMax Input Power (CW): 1000 WattsMax Input Power (Pulse): 2,500 WattsDimensions (Footprint): 50" x 25" x 17"Typical Configuration: 1PH/16 Amps AC, 250V/10A DC, RF feedthroughs N and SMA, Additional Passthrough, Window in DoorOptions: Lighting, USB, RS-232, HDMI and other filters, Video Camera System, Safety Interlock, Gas/Water Feedthrough, Stand with WheelsStandards Met: IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2, IEC 60118-13, and othersApplications: Radiated Emissions, Radiated ImmunityIN STOCK -
GTEM 500 Radiated Emission and Immunity Testing
SKU: 12326
Max EUT Size: 16" by 16" by 12.25"Standards Met: IEC/EN 61000-4-20Frequency Range: 9 kHz to 6 GHz (DC to 20 GHz Optional)Max Input Power: 500 Watts (2.5kW Pulse)Input Connector: 7/16 DinTypical VSWR: 1:1.2Applications: Radiated Immunity Testing, Radiated Emissions TestingTypically In Stock -
HA40G 18 GHz - 40 GHz Horn Antenna, 20 Watt Handling
SKU: 11861
Frequency Range: 18 GHz - 40 GHzApplications: Antenna Pattern Measurements, EmissionsTest Standards: IEC 61000-4-3Gain: 12 to 17 dBiConnector: K(f) Type