Overview
Teseq PMU 6003 Description
EMC immunity testing makes very specific demands on RF power meters. A large dynamic range, fast measurements, rugged design and a frequency range that matches the application are some of the unique requirements for power meters in an EMC test environment. The PM 6003 power meter has been specially designed with these features.
The PMU 6003 is designed for connection to the USB interface. It includes software that allows multiple power meter readouts at the same time. This device is powered from the USB interface. Drivers are available for optional Test House Software.
- IEC/EN 61000-4-6
- IEC/EN 61000-4-20
- CISPR 24
- EN 61000-6-1
- EN 61000-6-2
- IEC 60533
- IEC 60601-1-2
- IEC 61326
- MIL STD 461
- RTCA/DO 160
- ISO 11452-2
- ISO 11452-3
- ISO 11452-4
- ISO 11452-5
- SAE J1113-4
- SAE J1113-24
Parameter | Value |
---|---|
Frequency range | 9 kHz – 3 GHz |
Linear measurement range | -45 dBm to +20 dBm |
Max. input/no damage | +23 dBm |
Input return loss | >20 dB |
Connector | N male 50 Ω |
Control Software
The power meter is supplied with Windows-based control software. The software provides averaging, offset use, and the ability to switch units to dBm, dbμV or V. It can also handle simultaneous readouts of multiple power meters.