Solar Type 6220-1B Audio Isolation Transformer

Condition:
Used
Frequency Range:
30 Hz to 250 kHz
Audio Power:
200 W
Turns Radio:
2-to-1 step down
Secondary saturation:
50 A AC or DC maximum
Dielectric test:
600 V DC primary to secondaries and each winding to end bells
Size:
4.5" wide x 5.25 " high x 6.25" deep plus terminals. (11.43 cm x 13.335 cm x 15.875 cm)
Manufacturer:
Solar EMC
Online Orders Ship Same Day
$180.00

 

SKU:
3347-RE
Availability:

In Stock


Getting Started...

Overview

Solar Type 6220-1B TRANSFORMERS UPDATE

Effective January 2017, we have assigned new part numbers to our line of audio isolation transformers. Rest assured that the same performance you have trusted for more than 50 years has not changed.

Why the change after all these years? Because you, our valued customers, began requesting data and certificates of calibration for our transformers, which historically we did not provide.

The part number changes indicate that we will now provide for each transformer a serial number, a frequency response curve, a correction factor curve for the voltmeter winding, and a certificate of calibration with a five-year calibration cycle.

Solar Type 6220-1B APPLICATION

The Solar Type 6220-1B Audio Isolation Transformer was especially designed for screen room use in making conducted audio frequency susceptibility tests as required by MIL-STD-461/462 and other EMI specifications.

The transformer may also be used as a pickup device to measure low frequency EMI currents at lower levels than conventional current probes.

In addition, its secondary may be used as an isolating inductor in the power line during transient susceptibility tests.

Solar Type 6220-1B DESCRIPTION

The transformer is capable of handing up to 200 W of audio power into its primary over the frequency range 30 Hz to 250 kHz. The turns ratio provides a two-to-one step down to the special secondary winding. The secondary will handle up to 50 A of AC or DC without saturating the transformer.

Another secondary winding is connected to a pair of binding posts suitable for connecting to AC voltmeter as directed by the applicable EMI specifications. This winding serves to isolate the voltmeter from power ground. Neither the primary nor the secondary windings are connected to the end bells of the core. The transformer may be used as a 4 Ω primary and 1 Ω secondary or 2.4 Ω primary and 0.6 Ω secondary or 2 Ω primary and 0.5 Ω secondary.

SOLAR TYPE 6220-1B AUDIO ISOLATION TRANSFORMER
Insertion loss measured with 2 ohms on primary and 0.5 ohms on secondary

Solar Type 6220-1B Audio Isolation Transformer

Solar Type 6220-1B Specifications
Primary Less than 5 Ω
Secondary One-fourth the primary impedance
Frequency response 30 Hz to 250 kHz
(less than 5 dB at 30 Hz and less than 14 dB at 250 kHz when primary is loaded with 2 ohms and secondary is loaded with 0.5 ohms)
Audio power 200 W
Dielectric test 600 V DC primary to secondaries and each winding to end bells
Secondary saturation 50 A AC or DC maximum
Turns ratio Two-to-one step down
Secondary inductance Approximately 1.3 mH (unloaded)
Weight 18 pounds
Size 4.5" wide x 5.25 " high x 6.25" deep plus terminals. (11.43 cm x 13.335 cm x 15.875 cm)
Terminals Primary 3/4" spaced binding posts
Secondary 1/4 - 20 threaded studs spaced 1" apart
Voltmeter winding 3/4" spaced binding posts

Solar Type 6220-1B FIGURES

Solar Type 6220-1B Figure 1 Audio Susceptibility Test Setup For DC Lines


Solar Type 6220-1B Figure 2 Test Setup For Measuring Low Frequency, Low Amplitude EMI Current (See Application Note 622001)

Videos

Key Considerations

Manufacturer:
Solar EMC
Frequency Range:
30 Hz to 250 kHz
Audio Power:
200 W
Turns Radio:
2-to-1 step down
Secondary saturation:
50 A AC or DC maximum
Dielectric test:
600 V DC primary to secondaries and each winding to end bells
Size:
4.5" wide x 5.25 " high x 6.25" deep plus terminals. (11.43 cm x 13.335 cm x 15.875 cm)

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.