Overview
The EMC Shop is an ISO 17025 accredited calibration company with the Solar Type 6220-1B Audio Isolation Transformer in stock available for sale or rental. Repair and refurbishment services available as well. Contact us now for application support.
Solar Type 6220-1B TRANSFORMERS UPDATE
Effective January 2017, Solar has assigned new part numbers to their line of audio isolation transformers. Rest assured that the same performance you have trusted for more than 50 years has not changed.
Why the change after all these years? Because you, our valued customers, began requesting data and certificates of calibration for our transformers, which historically we did not provide.
The part number changes indicate that we will now provide for each transformer a serial number, a frequency response curve, a correction factor curve for the voltmeter winding, and a certificate of calibration with a five-year calibration cycle.
Solar Type 6220-1B APPLICATION
The Solar Type 6220-1B Audio Isolation Transformer was especially designed for screen room use in making conducted audio frequency susceptibility tests as required by MIL-STD-461/462 and other EMI specifications.
The transformer may also be used as a pickup device to measure low frequency EMI currents at lower levels than conventional current probes.
In addition, its secondary may be used as an isolating inductor in the power line during transient susceptibility tests.
Solar Type 6220-1B DESCRIPTION
The transformer is capable of handing up to 200 W of audio power into its primary over the frequency range 30 Hz to 250 kHz. The turns ratio provides a two-to-one step down to the special secondary winding. The secondary will handle up to 50 A of AC or DC without saturating the transformer.
Another secondary winding is connected to a pair of binding posts suitable for connecting to AC voltmeter as directed by the applicable EMI specifications. This winding serves to isolate the voltmeter from power ground. Neither the primary nor the secondary windings are connected to the end bells of the core. The transformer may be used as a 4 Ω primary and 1 Ω secondary or 2.4 Ω primary and 0.6 Ω secondary or 2 Ω primary and 0.5 Ω secondary.
SOLAR TYPE 6220-1B AUDIO ISOLATION TRANSFORMER
Insertion loss measured with 2 ohms on primary and 0.5 ohms on secondary
Solar Type 6220-1B Specifications | |
Primary | Less than 5 Ω |
Secondary | One-fourth the primary impedance |
Frequency response | 30 Hz to 250 kHz (less than 5 dB at 30 Hz and less than 14 dB at 250 kHz when primary is loaded with 2 ohms and secondary is loaded with 0.5 ohms) |
Audio power | 200 W |
Dielectric test | 600 V DC primary to secondaries and each winding to end bells |
Secondary saturation | 50 A AC or DC maximum |
Turns ratio | Two-to-one step down |
Secondary inductance | Approximately 1.3 mH (unloaded) |
Weight | 18 pounds |
Size | 4.5" wide x 5.25 " high x 6.25" deep plus terminals. (11.43 cm x 13.335 cm x 15.875 cm) |
Terminals | Primary 3/4" spaced binding posts Secondary 1/4 - 20 threaded studs spaced 1" apart Voltmeter winding 3/4" spaced binding posts |