Overview
Schloder CWG 520 3 Phase Coupling Network, 4 x 16 A - Burst and Surge
The coupling network (CDN) can be used to carry out EMC tests at 3 phase leads according to the standards IEC 61000-4-4 (Fast Transients) and IEC 61000-4-5 (Surge). The interference pulses of the burst generator or the surge generator are coupled to the power supply of the tested unit. The coupling paths can be changed by using the coupling switches. The coupling network can be remote from a personal computer via RS232- interface in connection with the burst generator SFT 1400 / 1420 or the surge generator CWG 1500.
Technical Data | |
Nominal voltage AC | max. 230 V / 400 V / 50 - 60 Hz |
Nominal voltage DC | max. 270 V (L -> L and L -> N, PE) |
Nominal/max. current | 4 x 16 A at 40° C ambient temperature |
Serial inductance | 5 x 150 µH / 16 A |
Current compensated choke | 4 x 1,5 mH / 16 A |
Phase indicating lamps | Green for L1, L2 and L3, red for N |
Coupling capacity | Burst coupling: 33 nF Surge coupling: phase - ground 9 µF / 12 ? phase - phase 18 µF / 2 ? |
Various coupling modes | Burst: L1-E, L2-E, L3-E, N-E, PE-E etc Surge: L1 - L2; L2 - L3 etc |
Input logic-signal | BNC - jack |
High voltage burst input | Burst: Fischer high voltage jack D103A023 |
High voltage surge input | Surge: Fischer high voltage jack D105A039 |
EUT feeding | laboratory-banana-jacks |
EUT connection | laboratory-banana-jacks |
Power supply electronic control system | IEC-plug 230 V / 50 Hz / 1 A on rear side |
Additional earth connection jacks | on front and rear side |
Temperature environment | 0 - 40 °C |
Cabinet | 19" housing, 3 HE |
Weight | approx. 20 kg |