Overview
- Automatic measurements: 77 functions available
- QuickMeas: key measurement results at the push of a button
- History function: looking back in time
- Mask test: settings in only seconds
- FFT function: the easy way to analyze the signal spectrum
- Search and navigation: focus on details
- Math functions: calculations made easy
- Reference waveforms: fast comparisons
Impedance | 50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF ± 1 pF(meas.) | |
Input sensitivity | max. bandwidth in all ranges | 50 Ω: 500 μV/div to 1 V/div 1 MΩ: 500 μV/div to 10 V/div |
Resolution | 8 bit (7-bit ENOB) | |
with high resolution decimation (sampling rate reduction) | 16 bit | |
with R&S®RTE-K17 high definition option (no sampling rate reduction) | 16 bit | |
Acquisition system | ||
Realtime sampling rate | max. 5 Gsample/s on each channel | |
Acquisition memory | standard configuration, per channel/1 channel active | R&S®RTE1000 Digital Oscilloscopes 2-channel model: 10/20 Msample R&S®RTE1000 Digital Oscilloscopes 4-channel model: 10/40 Msample |
max. upgrade (R&S®RTE-B102 option), per channel/1 channel active | R&S®RTE1000 Digital Oscilloscopes 2-channel model: 50/100 Msample R&S®RTE1000 Digital Oscilloscopes 4-channel model: 50/200 Msample | |
Acquisition rate | > 1 000 000 waveforms/s | |
Decimation modes | any combination of decimation mode and waveform arithmetics | sample, peak detect, high resolution, root mean square |
Waveform arithmetics | off, envelope, average | |
Horizontal system | ||
Timebase range | 50 ps/div bis 5000 s/div | |
Timebase accuracy | after delivery/calibration | ±5 ppm |
Channel deskew | ±100 ns | |
Trigger system | ||
Trigger types | edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video, serial bus trigger (optional) | |
Sensitivity | definition of trigger hysteresis | can be set automatically or manually from 0 div to 5 div |
Analysis and measurement functions | ||
Automated measurements | 77 measurement functions | |
Cursor measurements | 2 cursor sets, each consisting of two horizontal and two vertical cursors | |
Waveform mathematics | 4 math waveforms; mathematics, logical operations, comparison, FIR filter, FFT | |
MSO option | ||
Digital channels | 16 (2 logic probes) | |
Input impedance | 100 k || 4 pF | |
Sampling rate | 5 Gsample/s per channel | |
Acquisition memory | 100 Msample per channel | |
Parallel buses | up to 4 | |
General data | ||
Dimensions | W x H x D | 427 mm × 249 mm × 204 mm (16.81 in × 9.8 in × 8.03 in) |
Weight | without options, nominal | 8,6 kg (18.96 lb) |
Screen | 10.4" LC TFT color touchscreen, 1024 × 728 pixel (XGA) | |
Interfaces | 1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output |