EM Test Transient Generators Test Equipment, Systems & Solutions
-
3 Phase Harmonics & Flicker Test System IEC 61000-3-11 and 3-12
SKU: 11918
Standards Met: IEC 61000-3-11, IEC 61000-3-12, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-4-7, IEC 60601-1-2 and moreApplications: Flicker and Harmonics TestingCurrent Handling: 32 Amps per phaseInquire for Availability -
EM Test TSS 500N4B Telecom Surge Generator
SKU: 9122
Applications: Telecom Testing, Conducted ImmunityTest Standards: Bellcore/Telcordia GR-1089-CoreWaveform: 10/250usOutput Voltage: 100 Volts to 4,000 VoltsOutput Current: 50 Amps to 2,000 Amps$1,950.00In Stock -
EM Test TSS 500N6B Telecom Surge Simulator
SKU: 6885
Output Voltage: 100 - 5,000 VoltsOutput Current: 5 - 500 Amps per wireTest Standards: Bellcore/Telcordia GR-1089-CORE, ITU-T K.12, ITU-T K.28, ITU-T K.45Pulse Waveforms: 10/360µs, 10/1,000µs and 2/10µsTelecom Port Testing: 2-wire, 4-wire (up to 12 pair with CNB 500)$2,975.00In Stock -
EM Test PFS 500 Power Fail Simulator for EN/IEC 61000-4-11
SKU: 1144
Test Standards: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: Voltage dips, Voltage interruptions, Voltage variations, Inverse, EMC Precompliance Testing, Conducted ImmunityEUT Power Handling: AC up to 240V/16A$4,750.001 Unit -
Monthly Rental EM Test CWS 500N Continuous Wave Simulator for IEC 61000-4-6
SKU: sku-921
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInput: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)Maximum Continuous Power: 80W (nominal)Standards Met: IEC 61000-4-6Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, ServiceVoltage Rating: 1 V to 30 Volts Max -
Rent EM Test TSS 500M2F Telecom Surge Simulator for FCC Part 68
SKU: sku-776
Weight: approx. 35kgApplication/Test Type: Test levels as per FCC part 68Coupling: Telecom ports: Tip to Ground, Ring to Ground, Tip and Ring to Ground Power ports 250V/16A: L toN, L to PE, N to PE , L+N to PEDimensions: 19“ / 6HU,Output Current: 64A – 1,000A (power line) 20 – 200A per wire (surge A)Outputs: 4 mm banana socketPolarity: pos / neg / alternateRise time: Less than 2 usTelecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 160V – 2,500V ± 10% (power line) 160V – 1,500V ± 10% (surge A)Trigger of bursts: Automatic pulse release -
EM Test PFS 503N32 Power Fail Simulator, 3-phase 3x480V AC (p-p) max. 32A
SKU: sku-549
Weight: app. 28kg;Current Rating: Max. 32ADimensions: 19"/6 HUDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 50Hz/60Hz, Single phase applicationOutput: 3-phase application L1, L2, L3, N and PE on the rear panel. 1-phase application L, N and PE on the front panelPeak current: Better than 500ARepetition rate: 0.01s to 9,999sRise time: Between 1us and 5us for abrupt changes, generator loaded with resistive loadSupply Voltage: 115V/230V; +10/-15%Test Voltage: 3x480V AC resp. 3x690V AC (L-L) 277V AC resp. 400V AC 360V DC resp. 600V DC (L-N)Trigger of bursts: Automatic -
EM Test PFM 200N100.1 Automotive Power Fail Simulator for Power Supply and Data Lines
SKU: 10479
Test Standards: LV 124/LV 148, LV 123Inquire for Availability -
EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
SKU: sku-410
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInput: 115 V to 230 V +10/-15 %, 50/60 Hz (380 Watts Max)Maximum Continuous Power: 80W (nominal)Standards Met: IEC 61000-4-6Test Routines: Quick Start, User Test Routines, Standards Test Routines (IEC/EN 61000-4-6), Cal Procedure, ServiceVoltage Rating: 1 V to 30 Volts Max -
EM Test TSS 500N10 Telecom Surge Generator ITU-T for Enhanced Level Testing up to 10 kV
SKU: sku-403
Weight: approx. 37.1 kg (81.8 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/9 HU, 420 mm x 448 mm x 500 mmEnergy Storage Capacitor: 1 uF (Pulse 1.2/50 us) 20 uF (Pulse 10/700 μs) 20 uF (Surge Pulse B)Front Time: 1 us ± 30% (Pulse 1.2/50 us) 10 us ± 30% (Pulse 10/700 μs) 9 us ± 30% (Surge Pulse B)Pulse Duration: 50 us ± 20% (Pulse 1.2/50 us) 700 us ± 20% (Pulse 10/700 us) 720 us ± 20% (Surge Pulse B)Standards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.21 ITU-T K.28 ITU-T K.45 (and more)Telecom Surge: As per FCC part 68, Pulse B, IEC 61000-4-5, ITU and ETSI recommendationsTest Voltage: 500 V - 10,000 V ± 10% -
EM Test TSS 500N4 Telecom Surge Generator as per ITU / FCC up to 4 kV
SKU: sku-402
Weight: approx. 20 kg (44 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/3HUStandards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.28 ITU-T K.45 (and more)Voltage Rating: 160 V - 4,000 V ±10% -
EM Test UCS 500M4 Transient Simulator w/ Burst/EFT
SKU: 34111
Applications: EFT/Burst Testing, Dips Interrupts & Variations, EMC Precompliance TestingStandards Met: IEC 61000-4-4, IEC 61000-4-11Max EUT AC Voltage (w/ Built in CDN): 250 VoltsMax EUT AC Current (w/ Built in CDN): 16 AmpsMax EUT DC Voltage (w/ Built in CDN): 250 VoltsMax EUT DC Current (w/ Built in CDN): 10 AmpsEFT/Burst Pulse Output Capability: 4.4 kVDips & Interrupts: 16 – 500 HzInquire for Availability