EN/IEC 61000-4-6

(Showing 1 of 13)

The EMC Shop stocks and rents this test equipment, allowing customers to preliminary evaluate their products before attempting certification. The IEC/EN 61000-4-6 test standard should be purchased, read and followed to develop a suitable test plan and effectively evaluate your product.

Testing to IEC 61000-4-6?

IEC 61000-4-6 is a standard for testing electromagnetic disturbances along data and power lines that run to and from your product (DUT = Device Under Test). While intimidating to decipher the 89 pages of edition 5 of EN/IEC 61000-4-6, it's testing techniques are simple and will help flush out other problem areas that arise in EMC testing. Most of our custommers usually call in, rent equipment and contact us with the equipment in hand. Dialing in the test setup, sequence or anything else is usually quickly resolved to get testing underway.

IEC 61000-4-6 Procedure & Setup

    • In lab or in place?
    • Determine test levels and coupling devices
    • Performance Criteria
    • Description of the EUT exercising method
    • Setup equipment and run calibration
    • Identify nearby and external contributors (if any)
    • Run test and identify problem areas
    • The recovery time of the EUT if necessary
    • Troubleshoot accordingly

Most of our customers will simply place the test generator on a bench, ground everything, and be off and rolling. There are diagrams avaialble that specify spacing, insulation, placement of the generator, etc... We have found that in most cases, these aren't detrimental in precompliance measurements when following IEC 61000-4-6. The test standard is long and detailed, covering different test setups, injection methods, procedures and more. The EMC Shop can support this effort with information on your DUT and surrounding auxilary equipment.

Selecting CDN's According to IEC 61000-4-6

Calibration Setup Diagram acc. IEC 61000-4-6

Diagram - IEC 61000-4-6 CDN Test Setup

Test Setup Diagram acc. IEC 61000-4-6

Diagram - IEC 61000-4-6 Testing of Large Products

START TESTING

The EMC Shop ships IEC 61000-4-6 systems same day for fasy and easy precompliance testing.

Calibration Example

Test Equipment for IEC 61000-4-6

  • RF Conducted Immunity Test Generator
  • CDNs, EM Clamp or Current Clamp
  • Decoupling Device
  • Monitor Probe
  • 6dB Attenuator
  • 50 Ohm Terminations
  • Insulation Material
  • Grounding Plane
  • Calibration Kit (Optional)
  • RF Shield Room (Optional)

Show 12

EN/IEC 61000-4-6 Categories

EN/IEC 61000-4-6 Test Equipment, Systems & Solutions

  • EMIC-35 Current Injection Clamp for RF Conducted Immunity Testing

    SKU: sku-2132

    Weight: approx. 14 kg
    Application/Test Type: Injects the disturbance signal through a combination of inductive and capacitive coupling
    Clamp factor (CF): -.6 dB at 100 kHz to -2.2 dB at 1 GHz (Min -4 dB at 700 MHz
    Connector: N-type female
    Dimensions: 666 mm x 135 mm x 120 mm
    Frequency Range: 10 kHz to 1000 MHz
    Impedance: 50 Ohms
    Max. Cable Diameter: 35 mm
    Maximum Continuous Power: 0.15 to 100 MHz: 100 W for 15 min; 100 to 230 MHz: 100 W for 5 min; 230 to 1000 MHz: 50 W for 3 min
    Standards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326