AE Techron 4301 DC Voltage Variations and Telecom Transients Test System

Condition:
New
Test Standards:
GR-1089 Section 10 and ATIS-0600315.2007
Maximum Continuous DC Current (±50 VDC):
60-240 Amps (model dependent)
Maximum Pulse DC Current (up to ±100 VDC):
200-800 Amps (model dependent)
Voltage Gain:
20
Maximum Input Voltage:
±10V, unbalanced
Manufacturer:
AE Techron

 

Availability:

Inquire for Availability

SKU:
44557

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The AE Techron 4301 DC Voltage Variations and Telecom Transients Test Systems have been specially designed for EMC testing of network telecommunications equipment and are the best systems available for producing the waveforms required for transient voltage measurements as described in GR-1089 Section 10 and ATIS-0600315.2007.

Key Performance Capabilities:

  • Slew rates up to 60 V/µsec.
  • Up to 240A DC at +50VDC or –50VDC (4301-240 configuration).
  • Can provide pulses of up to 800 amps at voltages of up to ±100V (4301-240 configuration).
  • Adjustable compensation allows the system to maintain a 50V/2 µsec rise-time over a wide range of current outputs.

he 4301 includes a SDG2042X Function/Arbitrary Waveform Generator, which comes pre-programmed and integrated into the 4301 system. Together, the 4301 with Siglent AWG provide a complete solution for GR-1089 Section 10/ATIS-0600315.2007 testing.

The 4301 system is available in four standard configurations and is capable of slew rates of up to 60 V/µsec. In its largest configuration (model 4301-240), the 4301 system can provide up to 240A of DC at ±50VDC and can provide pulses of up to 800 amps at voltages of up to ±100V. The system has a voltage gain of 20 and can accept input voltages of up to ±10V.

Lower power versions of the 4301 amplifier solution are available for users with lower current requirements: 4301-180 (180A), 4301-120 (120A) and 4301-60 (60A).

Telecom Test Systems

  • Complete solution for GR-1089 Section 10 and ATIS-0600315.2007 DC Voltage Variations and Transients Testing
  • Siglent SDG2042X Function/Arbitrary Waveform Generator comes pre-programmed and integrated into the 4301 system
  • Four selectable compensation settings

Key Considerations

Manufacturer:
AE Techron
Test Standards:
GR-1089 Section 10 and ATIS-0600315.2007
Maximum Continuous DC Current (±50 VDC):
60-240 Amps (model dependent)
Maximum Pulse DC Current (up to ±100 VDC):
200-800 Amps (model dependent)
Voltage Gain:
20
Maximum Input Voltage:
±10V, unbalanced

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.