Power Fail Simulators Test Equipment, Systems & Solutions
-
Haefely AXOS5 Surge/EFT/Burst Impulse Generator up to 5 kV
SKU: 10180
Applications: Conducted Immunity Testing, CE Marking, Medical DevicesStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Max EUT AC Voltage (W/ Built In CDN): 264 VoltsMax EUT AC Current (W/ Built In CDN): 16 AmpsEFT/Burst Pulse Output Capability: 5.0 kVCombination/Wave Surge Output Capability: 5.0 kVDips, Interrupts & Variations: Requires DIP 116$975.00Typically In Stock -
3ctest PFS Single Phase Power Fail Simulator
SKU: sku-1108
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Applications: EMC Precompliance Testing, Conducted ImmunityEUT Power Handling: up to 260 Volts and 20 Amps (3 Phase models available)Rentals: Ship Same Day4-6 Weeks -
Teseq NSG 3060 Surge/EFT Generator
SKU: 1166
Test Capabilities: Combination Wave Surge Immunity, EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITEFT/Burst Pulse Output Capability: ±200 V to 4.8 kV (in 1 V steps)Combination/Wave Surge Output Capability: ± 200 V to 6.6 kV (in 1 V steps)External Coupling: Built-in CDN Specs reference CDN 3061 (INCLUDED), Optional - Data Lines (EFT & Surge), 3PH EUTDips & Interrupts: 0, 40, 70, 80% (INA 650x)Test Area: Conducted Immunity/Susceptibility TestingIN STOCK -
3ctest GN MT6 Multifunctional Transient Immunity Generator
SKU: 10541
Standards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 400 VoltsMax EUT Current (w/ Built in CDN): 20 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)EFT/Burst Pulse Output Capability: 6 kVCombination/Wave Surge Output Capability: 6 kVTypically In Stock -
EM Test NX5 Compact EMC Generator for EFT/Burst, Surge & Power Fail
SKU: 10547
Test Capabilities: Combination Wave Surge Immunity , EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11Applications: Conducted Immunity Testing, CE Marking, Medical DevicesMax EUT Voltage (w/ Built in CDN): 300 VoltsMax EUT Current (w/ Built in CDN): 16 AmpsPeak inrush current capability: 500 Amps (up to 2.5 kA)EFT/Burst Pulse Output Capability: 5.5 kVCombination/Wave Surge Output Capability: 5 kVExternal Coupling: Data Lines (EFT & Surge), 3PH EUTDips, Interrupts & Variations: 16 Hz - 500 Hz and DC$2,195.00Typically In Stock -
Teseq NSG 3040 Transient Immunity Test System
SKU: 4141
Test Capabilities: Combination Wave Surge Immunity, EFT/Burst, Dips Interrupts & VariationsStandards Met: IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-11, IEC 61000-4-29Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT Voltage (w/ Built in CDN): 264 VoltsMax EUT Current (w/ Built in CDN): 16 AmpsEFT/Burst Pulse Output Capability: 4.8 kVCombination/Wave Surge Output Capability: 4.4 kVGeneric Standards: IEC 61000-6-1, IEC 61000-6-2$1,495.00In Stock -
California Instruments 5001iX Flicker & Harmonics Generator
SKU: 6723
Current rating: 120 ampsVoltage ranges: 150-300 VoltsTest Standards: IEC/ISO 60601-1-2, IEC 61000-3-2, IEC 61000-3-3, IEC/EN61000-4-7, IEC/EN61000-4-15Applications: Flicker and Harmonics TestingTypically In Stock -
Teseq INA 6502 PQF/Dip Transformer for NSG 3060
SKU: 3955
Test Standards: IEC/EN 61000-4-11Compatible Generators: Teseq NSG 3060, Teseq NSG 3040Applications: Conducted Immunity$549.00In stock