Overview
The 3ctest LSS 160MS Multiple Stroke Lightning Transient Generator with color touch screen and PLC control system allows for automatically conducting testing with the push of a button. The unit satisfies the requirements of Current and Voltage waveforms per DO-160 Section 22 and the new MIL-STD 461G CS 117 test standard Levels 1 through 5.
Waveform 1:
- Waveform Type: Current
- T1: 6.4us ±20%
- T2: 69us ±20%
- Peak Output:
- First Pulse: 1600 Amps
- Subsequent Pulse: 800 Amps
- Peak Error: -0% + 10%
- Output Impedance: 1 Ohm
Waveform 4:
- Waveform Type: Voltage
- T1: 6.4us ±20%
- T2: 69us ±20%
- Peak Output:
- First Pulse: 1600 Volts
- Subsequent Pulse: 800 Volts
- Peak Error: -0% + 10%
- Output Impedance: 5 Ohm
Waveform 5A:
- Waveform Type: Current + Voltage
- T1: 40us ±20%
- T2: 120us ±20%
- Peak Output:
- First Pulse: 1600 Volts/1600 Amps
- Subsequent Pulse: 800Volts/800 Amps
- Peak Error: -0% + 10%
- Output Impedance: 1 Ohm
Waveform 5B:
- Waveform Type: Current + Voltage
- T1: 50us ±20%
- T2: 500us ±20%
- Peak Output:
- First Pulse: 1600 Volts/1600 Amps
- Subsequent Pulse: 800Volts/800 Amps
- Peak Error: -0% + 10%
- Output Impedance: 1 Ohm