Overview
Micropulses occur on the battery supply system when an inductive load is disconnected from the DC supply. These pulses are of a medium energy content having a rise time in the low microsecond range and a duration of several tenth or hundreds/thousands of microseconds. Their polarity depends on whether the inductive load is of a passive (e.g. a heater) or an active type (e.g. a DC motor).
EM Test MPG 200 Description:
The EM Test MPG 200S20 has a built-in battery switch to interrupt the DC supply voltage as required by the standards. It is designed to generate pulses 1b and 6 as per GOST standard 28751-90 as well as pulse 6 as per ISO 7637-1:1990.
EM Test MPG 200 Benefits:
The EM Test MPG 200S20 includes everything necessary to conduct fully compliant tests. The built-in electronic battery switch enables interruption of the DC supply voltage as required by the standards. The MPG 200S20 is a standalone tester including a 60V/25A DC coupling/decoupling network but still it can be integrated easily into a complete test system.
Operation is both manual and by software via GPIB or RS232. Fail inputs allow to control an ongoing test sequence based on the status of the DUT. A warning lamp control contact and a safety interlock is provided.
Pre-programmed Standard Test routines allow highest user convenience. Still the MPG 200S20 offers the Quick Start test routine where parameters can be changed on-line during the test to evaluate the susceptibility level of an individual DUT.
PULSE SPECIFICATIONS
- Voltage (o.c.) U = 50V - 1,100V ± 10%
- Int. resistor selectable 30ohm, 50ohm, 100ohm, 150ohm, 200ohm other values: by external plug-in module
- Polarity Positive/negative
GOST PULSE 1B (24V)
- Voltage (o.c.) 50V - 1,100V Rise time 9us +0%/- 50% (10 - 90%)
- Pulse duration 1ms ± 10% (10 - 10%)
- Int. resistor 50ohm ± 10%
ISO PULSE 6 (12V/24V)
- Voltage (o.c.) 25V - 400V
- Rise time 60us +0%/-50% (10 - 90%)
- Pulse duration 300us ± 10% (10 - 10%)
- Int. resistor 30ohm ± 10%
TRIGGER
- Automatic Automatic release of the pulses
- Repetition rate 0.2s - 99.0s
- Manual release of a single pulse
- External release of a single pulse
- Supply switch Off time, selectable; 0 - 10,000ms
OUTPUT
- DUT supply +/- Safety laboratory connectors
- Coupling To the battery +line
- Decoupling Via diode and battery supply switch DUT supply Max. 60V/25A
TEST ROUTINES
- Quick Start Immediate start; easy-to-use and fast
- User Test routines Change voltage after n pulses
INTERFACE
- Serial interface RS 232, baud rate 1,200 - 19,200
- Parallel interface IEEE 488, address 1 - 30
- CN interface To control external coupling network