Lumiloop LSProbe 2.0 CW and Pulse Field Probe, 9 kHz - 18 GHz
SKU: 51903
Application/Test Type: Radiated Immunity, Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF roomsField Strength Range: <1 V/m to 1,000 V/m (5 kV/m under 1 GHz)Frequency Range: 9 kHz to 18 GHzResolution: <0.05 V/mTest Standards: MIL-STD 461 RS103, DO-160Typically In Stock -
Amplifier Research FL8018 Isotropic Field Probe, CW and Pulse, 18 GHz
SKU: 11018
Frequency Range: 20 MHz - 18 GHzMeasurement Type: CW, AM & PulseField Strength Range: 2 – 1000 V/mDynamic Range: >54 dBIsotropic Deviation (Measured at Ortho Angle): ±0.5 dB @ 100 MHzApplications: Automotive EMC, Commercial EMC, Aviation EMC, Military EMC, Wireless R&DStandards Met: MIL-STD 461 RS103, DO-160Additional Standards Met: IEC 61000-4-3Inquire for Availability -
Lumiloop LSProbe 1.2 Laser Powered Field Probe for CW and Pulse Testing
SKU: 7384
Application/Test Type: Radiated ImmunityField Strength Range: 0.1 V/m to 1,000 V/m (7 to 10 kV/m under 30 MHz)Frequency Range: 10 Hz to 8.2 GHzResolution: <0.01 V/mTest Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20Typically In Stock -
ETS-Lindgren FP5083 Isotropic Electric Field Probes
SKU: 5972
Dynamic Range: 3 to 300 Volts/meter (V/m)Frequency Response: 80 MHz - 26 GHz (± 1.5 dB), 26 GHz - 40.0 GHz (± 3.0 dB)Ranges: 10, 30, 100, 300 V/m full scaleAverage Overload: 6 times full scale (each range)Battery Life: 17 Hrs continuous (full charge)$995.00Typically In Stock -
Wavecontrol WPF3-HP 100 kHz - 3 GHz E-Field Probe
SKU: 12068
Field Strength Range: 0.2 - 1,000 V/mApplication/Test Type: Monitoring electric field strengthsVideos: Menu Run-ThroughFrequency Range: 100 kHz - 3 GHzTypically In Stock -
Amplifier Research PL7004 800MHz - 3.6GHz Electric Field Pulse Laser Powered Probe
SKU: 11935
Amplitude Accuracy: Without correction factors applied: ±1.5 dB @ 1 GHz; With correction factors applied: Typical expanded measurement uncertainty (95% confidence interval), 0.8 dB, 800 MHz–1 GHz; 1.4 dB, 1GHz–3.6 GHzCalibration Data: Accredited Calibration Report supplied with probeDamage Level: 1000 V/m, Continuous Field or Pulsed FieldFiber Optic Connectors: Two E2000 Compact Duplex Connectors at 1 Meter, Includes Fiber Optic Verification Loop.Frequency Range: 800MHz - 3.6GHzIsotropic Deviation: ±1.0 dB @ 1 GHz. For improved accuracy, this probe should be used with a single axis aligned with the E-field being measured.Measurement Data Processing: The pulse amplitude measurement is smoothed before being sampled and digitized. The smoothing process has a time constant of 300 msec.Operating Range: 80–800 V/mPulse Duration: 0.02% to 2%Pulse Measurement Variation: Over Range of Pulse Width, Period, and Duty relative to a 10 microsecond pulse width and 1 millisecond pulse period (1kHz pulse rate, 1% duty): ±0.5 dB/–1.0 dB typicalPulse Period: Up to 5 milliseconds between pulses (greater than 200 Hz pulse rate)Pulse Width: 1 to 100 MicrosecondsRelative Flatness: ±2.5 dB, 800 MHz-3 GHz; ±3.0 dB, 3.0GHz 3.6GHzTemperature Stability: +0.5 dB Over Operating Temperature Range -
Amplifier Research FL7030 5 kHz - 30 MHz Electric Field Laser Powered Probe
SKU: 11934
Weight: 62.5 g (2.2 oz)Accuracy: ±1.0dB @ 10MHz1 0.8dB, 100kHz–1GHz3,4 1.4dB, 1GHz–6GHz3,4Analog Response Time: 20 msec/up to 50 samples per second, at FI7000 USB and GPIB interfacesCalibration Data: Accredited Calibration Report (A2LA) supplied with probeDamage Level: 1000 V/m continuous fieldData Returned From Probe: X, Y, Z axes, and CompositeDimensions: 5.7 x 5.7 x 5.7 cm (2.25 x 2.25 x 2.25 in) 2.92 cm (1.15 in) DIA spherical housing 3.18 cm (1.25 in) sensor radome per axesFiber Optic Connectors: Two E2000 compact duplex connectors at 1 meter, includes fiber optic verification loop.Isotropic Deviation: ± 0.5 dB @ 10 MHz ± 0.5 dB, 5 kHz–30 MHz (typical)Linearity: ± 0.5 dB and ± 0.9 V/mOperating Range: 1.5–300 V/mOperating Temperature: 10˚C to 40˚C (50˚F to 104˚F) @ 5% to 95% RH non-condensingPower Requirements: Laser powered from FI7000 interfaceRise time: Typical Analog 300nSTemperature Stability: ± 0.5 dB over operating temperature range -
Amplifier Research FP7060 E-Field Probe Kit, 27 MHz – 60GHz, 0.7–300 V/m
SKU: 11650
Weight: 350g approxApplication/Test Type: electric field measurement instrument for use in EMC and EMI applicationsBattery: 2 built-in NiMH batteries, size AA, rechargeable, changed by operator, 40 hours operating life per charge.Communication: 10 m glass cableDimensions: Approx. 420 x 85 x 65 mm including base and probeFrequency Range: 27MHz–60GHzMeasurement Mode: composite valuesOperation Time: 40 hours operating life per charge.Recharging Time: Standard recharger included, 3 hour charge timeRF Field Probes: E-FieldSampling Rate: 60Hz, 50Hz, 5 Hz. - user selectableSensors: Isotropic -
Narda PMM EP-602 5 kHz - 9.25 GHz Broadband Active Electric Field Probe
SKU: 5497
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 1.5 to 1500 V/m (0.01 V/m)Frequency Range: 5 kHz to 9.25 GHzStandard Met: IEC/EN 61000-4-3Interface: Fiber-OpticBattery Life: 60-80 hoursDynamic Range: 1,5 to 1500 V/m, 60 dB single rangeTypically In Stock -
EFP60G Broadband EMF Probe
SKU: 5304
Frequency Range: 2 MHz - 60 GHzField Strength Range: 4 - 1000 V/m, 4 – 270 mW/cm2Linearity: +/- 1.5 dBApplications: RF Interference Analysis and EMF SniffingRotational Isotropicity: +/- 3 dBConnector Type: SMA(f)Typically In Stock -
Amplifier Research FP2083 Isotropic RF Electric Field Probe
SKU: 5971
Frequency Range: 80 MHz to 40 GHzField Strength Range: 300 V/mApplications: Monitoring Electric Field Strengths, Radiated ImmunityStandards Met: IEC/EN 61000-4-3Was:$495.00$395.00In Stock -
Narda PMM EP-603 300 kHz - 18 GHz Isotropic E-Field Probe
SKU: PMM EP-603
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 0.17 - 170 V/m (0.01 V/m)Frequency Range: 300 kHz to 18 GHzStandards Met: IEC/EN 61000-4-3Interfaces: Fiber-OpticBattery Life: 60-80 hours