Overview
EFT/Burst Generator Pulse 5/50ns
EFT 500Nx series – an EFT/Burst generator – is an intelligent solution offering exactly what you need for full-compliance immunity tests against Electrical/Fast transients phenomena. The distinct operation features, convenient EUT connection facilities, a clearly arranged menu structure and display philosophy as well as the pre-programmed standard test routines make testing easy, reliable and safe.
Extendable by a variety of test accessories the EFT 500Nx is a universal equipment for abroad range of recommendations even for three-phase applications up to 100A.
- IEC 61000-4-4
- IEC 61000-4-4 Ed 3
- EN 61000-4-4
- EN 61000-4-4 Ed 3
As of 2016, the EM Test EFT 500N5.8 is a top of the line electrical fast transient (EFT/Burst) generator. A built in 3 phase coupler capable of 690V per line at 32 amps, any DUT can be hooked up and injected with EFT for evaluation and compliance to IEC 61000-4-4, ANSI C62.41, IEC 60601-1-2 and all other test standards requiring an immunity from electrically fast transients.
Technical Data | ||
EFT Electrical Fast Transients Burst as per IEC 61000-4-4 | ||
Test Level | N5 / N5.x | N8 / N8.x |
Open circuit | 200V - 4800V ± 10% Step 20V | 1000V - 7000V ± 10% Step 50V |
Wave shape into a 50Ω load | 100V - 2400V | 500V – 3500V |
Rise time tr | 5ns ± 30% | |
Pulse duration td | 50ns ±30% | |
Rise time tr | 5ns ± 30% | |
Pulse duration td | 35ns - 150ns | |
Source impedance | Zq = 50Ω ± 20% | |
Polarity | Positive / Negative | |
Output | ||
Test Level | EFT 500 N5 /N5.4 /N5.5 / N5.6 / N8 /N8.2 |
EFT 500 N5.2 /N5.7 / N5.8/N8.1 |
Direct via 50Ω coaxial connector | To connect ext. coupling devices | |
Coupling network | To L, N, PE all combinations | |
EUT power mains AC 50/60Hz | 250 V / 16 A N5/ N8 250 V / 32 A N5.5/ N5.6/ N8.2 690 V / 32 A N5.4 |
3 x 440V/16A EFT N5.7 3 x 440V/32A EFT N5.1/N8.1 3 x 440V/50A EFT N5.2 3 x 690V/32A EFT N5.8 |
EUT DC power | 270V / same as AC | 270V / same as AC per line@@ |
Max Output voltage to 3-phase coupling may be reduced | ||
EUT power supply fuse | The EUT power supply fuse must be installed external. The fuse dimension must match the rated current of the devices EUT current | |
Test routines | ||
Quick Start | Immediate start, all parameters adjustable during a running test | |
Standard test as per | IEC 61000-4-4 : N5 level 1 ... level 5 Level X - Level Y |
N8: level 1 ... level 4 |
User test routines | Customized test routines Voltage change after T by ?V Frequency change after T by ?f Frequency sweep in one single burst Change duration after T by ?td Change polarity after T Statistical burst release Synchronized at fixed angle |
|
Safety | ||
Safety circuit | Control input ( short circuit ) | |
Design | as per IEC 1010, EN 61010 | |
Interfaces | ||
USB | USB (compatible to USB 1.1 and 2.0); optical for N8 models | |
IEEE | Parallel, addresses 1-30 | |
CN port | Control of CNE 503 for 3-ph testing | |
Opto Link | Optical interface |
General Data | ||
Dimensions and Weight | ||
Device | Weight | Dimension |
EFT 500N5 | 12.6 kg | 19" / 3 HU |
EFT 500N5.1 | 22.4 kg | 19" / 6 HU |
EFT 500N5.2 | ca. 40 kg | 19" / 6 HU |
EFT 500N5.3 | 12.0 kg | 19" / 3 HU |
EFT 500N5.4 | 20.0kg | 19" / 6 HU |
EFT 500N5.5 | ca. 20.0kg | 19" / 6 HU |
EFT 500N5.6 | 13.5kg | 19" / 3 HU |
EFT 500N5.7 | 17.0kg | 19" / 6 HE |
EFT 500N5.8 | 22.6kg | 19" / 6 HE |
EFT 500N8 | 14.4kg | 19" / 6 HU |
EFT 500N8.1 | ca 40 kg | 19" / 6 HU |
EFT 500N8.2 | 20.0kg | 19" / 6 HU |
Power supply | 115V/230V +10/-15% 50/60Hz | |
Power supply | 115V/230V +10/-15% 50/60Hz | |
Power | 265W max. | |
Fuses | 230V : 2 x T 2A slow blow 115V : 2 x T 4A slow blow |