Schwarzbeck CDN USB-C Coupling Decoupling Network for IEC 61000-4-6

Associated Equipment:
RF Conducted Immunity Test Systems
Test Standards:
IEC/EN 61000-4-6
Manufacturer:
Schwarzbeck
Online Orders Ship Same Day

 

SKU:
11217

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The Schwarzbeck CDN USB-C is part of the coupling decoupling network series for conducted common mode immunity testing according to IEC/EN 61000-4-6. The CDN S24 USB-C is compliant to IEC 61000-4-6 figure D.1 and is suitable for immunity testing on screened USB-C lines.

The CDN S24 USB-C is intended to measure EuTs with USB-C interface in the frequency range from 150 kHz to 230 MHz. The circuitry is shown in Fig. 3.

The USB-C standard allows connecting two devices via a single cable with two connectors. There are no additional connectors allowed and female-female adaptors disable the polarity sensing of the reversible USB-C connectors.

For this reason the AE connector is a fixed cable with a male plug.

Since the CDN USB-C needs to be connected directly to the calibration adapter the EuT connector cannot be a cable. The CDN USB-C is wired so that the USB-C polarity sensing still works correctly.

To ensure that the total loss is within USB limits it is important to use the shortest possible USB cable for EuT connection (20cm recommended)

All CDNs comply with the requirements of IEC 61000-4-6. Each CDN comes with individually measured data and a calibration certificate for the common mode impedance and the voltage division factor. Further typical data for the phase (not normative) can be found in fig. 2

A variety of calibration adapters and other accessories are available as option. With the included adapter SA USB-C in conjunction with the optional series resistor SR100-6W, the required spacing of 30 mm is obtained as depicted in Fig. 9 of IEC 61000-4-6.

The connection to ground can be accomplished using the ground plane of the CDN. Additionally there is a M4 thread located at the AE side to ground as well as a 4 mm socket to connect the device to ground.

Fig. 1: Schwarzbeck CDN USB-C Coupling Decoupling Network for IEC 61000-4-6
Fig. 2: Schwarzbeck CDN USB-C Coupling Decoupling Network for IEC 61000-4-6
Fig. 1: typ. EuT common mode impedance Fig. 2: typ. voltage division factor RF-port to EuT-port

Fig. 5: Schwarzbeck CDN USB-C Coupling Decoupling Network for IEC 61000-4-6
Fig. 3: Principal Circuitry CDN S24 USB-C

Specifications
Frequency range 150 kHz … 230 MHz
Common mode impedance 150 kHz – 24 MHz: 150 ? ±20 ?
24 MHz–80 MHz: 150 ? +60 ? / -45 ?
80 MHz–230 MHz: 150 ? ±60 ?
Max. RF-test voltage (emf) 30 V
RF-input-power 6 W (continuous)
RF-input-connector 50 ? BNC (female)
Voltage division factor RF-input – EuT-por 9.5 dB 150 kHz – 80 MHz: ± 1dB 80 MHz – 230 MHz: +3 dB / -2 dB
Housing material Aluminium
Housing dimensions 216 x 105 x 108 mm
Weight ca. 1.7 kg
EuT, AE connectors USB type C female
USB type C male (with cable)
Included accessories SA USB-C
Ground Adapter (one unit included by default)
Optional accessories:
50 ? to 150 ? adapter:
SR100-6W

Key Considerations

Manufacturer:
Schwarzbeck
Associated Equipment:
RF Conducted Immunity Test Systems
Test Standards:
IEC/EN 61000-4-6

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.