Keytek E503 Ring Wave Simulator for ANSI/IEEE C62.4 and UL 864

Condition:
Used
Pulse current (short circuit):
Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
Pulse repetition:
1 shot/9 seconds
Pulse voltage (open circuit):
200V - 6.6kV ± 10%
Ringwave 0.5 μs/100 kHz:
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Standards Met:
ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864
Manufacturer:
Thermo Keytek
Online Orders Ship Same Day

 

Availability:

IN STOCK

SKU:
sku-546

 

This product is available for shipping to North America and Western European countries.


Getting Started...

Check out our Google Reviews

Overview

The Thermo Fisher Keytek E503 Simulator systems are a sesoned favorite being used for electromagnetic Surge and EFT testing for more than 2 decades. The controller has an easy-to-use Windows based application software for quick implementation of test routines and standards, with automoatic report generation. A multi-level system interlock architecture provides maximum safety to keep first time users safe.

This rental ECAT system is suitable for users looking to evaluate DUT in a precompliance environment for passing Surge and Burst (Electrical Fast Transient) immunity test standards such as IEC 61000-4-4, IEC 61000-4-5 and ANSI C62.41. The single phase, 15 amp coupling network is suitable for most commercial electronics and lower powered electronics.

E503 Ringwave Simulator Configuration:

  • E103 Controller (fiber-interface for remote control)
  • E503 Ring Wave Simulator to 6.6kV (ANSI/IEEE C62.41 Cat. A and B and UL 864)
  • E4551A Single Phase Surge/EFT Coupler 250V rms (typ. 15 Amps)
  • Optional Modules Available (Call to Configure)
    • E411 EFT/Noise Burst Simulator to 4.4 kV (IEC 61000-4-4)
    • E421 EFT/Noise Burst Simulator to 8 kV (IEC 61000-4-4)
    • E501B Surge Simulator to 6.6 kV (IEC 61000-4-5, ANSI C62.41 Cat. B and UL 1449 at 3kA)
  • Input voltage: 100V to 240VAC
  • Input Current: 3.5A at 100 V; 1.5A at 240 V
  • User Manual
  • NIST Calibration Certificate

Key Considerations

Manufacturer:
Thermo Keytek
Pulse current (short circuit):
Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.
Pulse repetition:
1 shot/9 seconds
Pulse voltage (open circuit):
200V - 6.6kV ± 10%
Ringwave 0.5 μs/100 kHz:
Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41
Standards Met:
ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864