Com-Power Categories
Com-Power Test Equipment, Systems & Solutions
-
Com-Power LI-3P-2100 9kHz - 30MHz Three Phase LISN for CISPR / ANSI
SKU: sku-895
Frequency Range: 9 kHz – 30 MHzInductors: 50Ω, 50/250 μH +5Ω, (4) Conductor NetworkMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-3P-232 Three Phase LISN for CISPR / ANSI
SKU: sku-893
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent rating: 32 AmperesDimensions: 19.3” x 13.9” x 2.3″Frequency Range: 9 kHz – 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω – N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2 -
Com-Power LI-150C Line Impedance Stabilization Network
SKU: sku-890
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 50 Amps (AC), 35 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 5 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LIN-120C Line Impedance Stabilization Network
SKU: sku-889
Weight: 10 lbs (4.5 kg)Application/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amps AC (rms) , 14 Amps DCDimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)Frequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUTRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2, ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LI-125C 150 kHz to 30 MHz Line Impedance Stabilization Network Pair
SKU: sku-881
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 25 Amps (AC), 17 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LI-3P-216 LISN, 9 kHz to 30 MHz, 50/250 uH, 500 VAC
SKU: 11665
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesDimensions: 19.3” x 13.9” x 2.3"Frequency Range: 9 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V$5,795.00SHIPS IN 3-5 DAYS -
Com-Power LI-3P-1100 150 kHz - 30 MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-600
Weight: 71.5 lbsApplication/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 100 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-163 150kHz - 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-599
Weight: 52.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 63 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-116 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-597
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VCISPR 16-1-2: YesDO-160F: YesCISPR 22: YesFCC: YesANSI C63.4: Yes$395.00 - $5,350.00 -
Com-Power LIT-930A 9kHz to 30MHz Transient Limiter
SKU: 8409
Connector: N type (input and output)Dimensions: L 4.3” (100 mm) W 2.0” (50 mm) H 1.5” (35 mm)Frequency Range: 9 kHz - 30 MHzInput: 4 Watts CW (+36 dBm) ±50 VdcInsertion Loss: 10 dB +1.5 / -0.5 dB*VSWR: 1.1:1$650.00Typically In Stock -
Com-Power LIT-153A 150kHz to 30MHz Transient Limiter
SKU: sku-446
Connector: N type (input and output)Dimensions: L 3.0” (75 mm) W 1.25” (32 mm) H 1.25” (32 mm)Frequency Range: 150 kHz - 30 MHzInput: 2 Watts CW (+33 dBm) ±10 VdcInsertion Loss: 10 dB +1.5 / -0.5 dB*VSWR: 1.1:1$430.00 -
Com-Power CGO-51000 Comb Generator 1 GHz - 40 GHz 1 GHz steps
SKU: 43011
Weight: 2.5 lbs (1.1 kg)AC Power Adapter: 6 VDC 500 mAAntennas: Integral Stub-type (w/protective cover)Application/Test Type: Radiated Reference Signal Source (for OATS, SAC, FAC, etc.)Battery: 6V NiMH, 1 AhDimensions: 7 in. x 1 in. (17.8 cm x 2.5 cm)Frequency Range: 1 GHz to 40 GHz in 1 GHz stepsOperation Time: 18 Hours Typical With Fully Charged BatteryPolarity: Vertical, HorizontalInquire for Availability