Overview
The EMC Shop is an ISO 17025 accredited calibration company with the York EMC Eurofins CNE VI Comparison Noise Emitter in stock available for sale or rental. Repair and refurbishment services available as well. Contact us now for application support.
The CNE VI is a broadband noise source that is capable of producing a continuous noise output within the 30 Hz to 6 GHz frequency range. The broadband nature of the output enables the observation of details within the spectrum that would be missed using a comb generator.
The CNE VI features two separate outputs; a 50 Ω BNC connector for the 30 Hz to 30 MHz signal and a 50 Ω N-type output connector for the 30 MHz to 6 GHz signal. For radiated operation, either output can be attached to a selection of antennas available in a range of frequency coverage and types. An IEC 320 adapter is also available to provide a connection to LISN equipment, as well as an RJ11/ RJ14/RJ25/RJ45 adapter for connection to telecoms ISNs.
The CNE VI is an ideal source for carrying out checks on Open Area Test Sites (OATS) and fully- or semi-anechoic
chambers. The CNE VI is compact and battery powered, allowing operation as an electrically small source, which minimises the effect of the CNE VI itself when characterising the electromagnetic environment. The CNE VI is housed in a
metal enclosure so that it can be mounted in direct contact with a metal ground plane as may be required by some tests.
Features
- Continuous, broadband output
- Full spectrum measurements and analysis
- Stable output
- Repeatable measurements
- Conducted and radiated options
- Evaluation of both conducted and radiated systems
- 30 Hz to 6 GHz output
- Applications across a broad range of frequencies
- Compact and portable
- Comparisons between sites and environments
- Battery powered
- No power or interconnecting cable effects on measurements
Applications
-
Validation and verification of radiated and conducted measurement systems, such as:
- Open Area Test Sites (OATS)
- Fully Anechoic Rooms (FAR)
- Semi-Anechoic Chambers (SAC)
- Gigahertz Transverse ElectroMagnetic (GTEM) cells
- Line Impedance Stabilisation Network (LISN)
- Impedance Stabilisation Network (ISN)
-
Reference source for:
- Daily pre-test checks as required by accreditation authorities (e.g., ISO 17025, DEF STAN 59-411)
- Long-term performance monitoring
- Cable position investigation
- Investigation of screened room behavior
- Characterization of filter performance
- Cable loss measurements
- Measuring amplifier gain and bandwidth
- Spectrum analyser/receiver pre-check
- Investigation, characterization, and comparison of different measurement environments (e.g., OATS, FAR, SAC)
- Inter-laboratory test programs
- Proficiency test programs
Specifications: Noise Mode 1
Frequency Range
- 30 Hz to 30 MHz direct connection into 50 Ω system
- Up to 30 MHz radiated using a 1 m monopole
- Up to 30 MHz radiated using loop antennas
Output Connector
-
50 Ω BNC-type socket
Temperature Stability
-
<+/-0.5 dB between 30 Hz to 30 MHz, from 5°C to 40°C
Time Stability
-
Typically <1 dB over a 12 month period
Operating Time
-
14 hours typical with alkaline cells
Specifications: Noise Mode 2
Frequency Range
- 30 MHz to 6 GHz direct connection into 50 Ω system
- 30 MHz to 6 GHz radiated using MON03 monopole and MCN03 monocone antennas
Output Connector
-
50 Ω BNC-type socket
Temperature Stability
- <+/-1 dB between 30 MHz to 6 GHz, from 15°C to 30°C
- <+/-1.5 dB between 30 MHz to 6 GHz, from 5°C to 40°C
Time Stability
-
Typically <1 dB over a 12 month period
Operating Time
-
6.5 hours typical with alkaline cells
Specifications: Other
Dimensions
- 120 mm x 120 mm x 60 mm
- 140 mm x 140 mm x 79 mm including connectors, switches
Weight
-
1 kg (including cells)
Power Supply
- 4 x 1.5 V cells (AA or equivalent). Alkaline or rechargeable NiMH
Indicators
- Active
- Low battery
Controls
- Rotary switch for mode selection including OFF