Categories
Test Equipment
-
Teseq KEMA 801A RF Attenuation Clamp/Decoupling Network for IEC 61000-4-6
SKU: sku-122
Weight: approx. 5.5 kgDimensions: 670 mm x 100 mm x 79 mmFrequency Range: 150 kHz to 1000 MHzMax. Cable Diameter: 20 mmStandards Met: IEC/EN 61000-4-6; CISPR 24; EN 61000-6-1; EN 61000-6-2; IEC 60533; IEC 60601-1-2; IEC 61326 -
Teseq (Schaffner) KEMZ 801A EM Clamp Conform with IEC/EN 61000-4-6
SKU: sku-119
Weight: approx. 7 kgApplication/Test Type: Injects the disturbance signal through a combination of inductive and capacitive couplingClamp factor (CF): Max (0.15 to 400 MHz): 4 dB (50 Ω system) and 13.5 dB (150 Ω system)Connector: N-type femaleDimensions: 647 mm x 130 mm x 105 mm -
Teseq INA 6501 Manual Step Transformer for AC Dips & Interruptions
SKU: sku-116
Accuracy: ±5%Input voltage UIN: 0 to 250 VAC, 50/60 HzOutput voltage UVAR: 4 steps: 0% - 40% - 70% - 80% of UINVoltage change with load: 00% output, 0 to 16 A less than 5%; 80% output, 0 to 20 A less than 5%; 70% output, 0 to 23 A less than 5%; 40% output, 0 to 40 A less than 5%$2,060.00 -
$2,495.00
-
EM Test (Lüthi) M2 Coupling/Decoupling Network M-Type CDN for 2 Mains AC/DC Power Lines
SKU: sku-104
Application/Test Type: Coupling/decoupling networks for Conducted immunity, 2 mains AC/DC power supply linesCurrent Rating: 16,32,50,75,100 Amps (Max)Frequency Range: 150 kHz to 230 MHz (10 kHz - 80 MHz Optional)Mains & EUT Connections: AE: IEC 60320/C14 connector EUT: 4mm safety lab connectorsRF Input Voltage: 30 V (Max) -
Com-Power CDN-AF8E 150kHz - 230MHz Coupling Network Eight Wire Unscreened, Unbalanced Cables
SKU: sku-102
Weight: 5 lbs. 2.3 kgApplication/Test Type: Eight wire unscreened, unbalanced CablesCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 5 Amps (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE) -
Com-Power CDN-USB-AE USB CDNs with Type A Connector
SKU: sku-98
Weight: 2 lbs. 0.9 kgApplication/Test Type: USB cable with type A connectorCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 1 Amp (Max)Decoupling of Common Mode Disturbance: ≥ 50dB (EUT/AE) -
Com-Power CDN-T8SE Sheilded/Screened with 4 Balanced Conductor Pairs for immunity testing
SKU: 8504
Weight: 2 lbs. 0.9 kgApplication/Test Type: Four screened, balanced pairsCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 1.5 Amp (Max)Decoupling of Common Mode Disturbance: 150 KHz ≥ 45dB (RF/AE) 500 KHz ≥ 50dB (RF/AE) 230 MHz ≥ 50dB (RF/AE) -
Com-Power CDN-C75E Coupling Decoupling Network for Screened Cables
SKU: sku-96
Weight: 5 lbs. 2.3 kgApplication/Test Type: 75 Ohm Coaxial CablesCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 1 Amp (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE) -
Com-Power CDN-T8E Unshielded/Unscreened Cable with 4 Balanced Conductor Pairs
SKU: sku-94
Weight: 5 lbs. 2.3 kgApplication/Test Type: Four unscreened, balanced pairCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 1.5 Amps (Max)Decoupling of Common Mode Disturbance: 150 KHz ≥ 45dB (RF/AE) 500 KHz ≥ 50dB (RF/AE) 230 MHz ≥ 50dB (RF/AE) -
Com-Power CDN-M425E 3-Phase + Earth Coupling Decoupling Network
SKU: sku-90
Weight: 5 lbs. 2.3 kgApplication/Test Type: Four conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE) -
Com-Power CDN-M325E 150 kHz - 230 MHz 3-Line RF Coupling Decoupling Network
SKU: 4845
EMC Standard: IEC/EN 61000-4-6Application/Test Type: Three conductor power cableAssociated Equipment: RF Conducted Immunity Test SystemsCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Typically In Stock