Test Equipment, Systems & Solutions
-
PMM L3-64/690V 690 Volt LISN for IEC 60309, UL1682, UL1686
SKU: 10264
Weight: 50 kg (110 pounds)Application/Test Type: Ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains.Current Rating: 63 Amps Max (IEC60309); 60 Amps Max (UL1682, UL1686)Dimensions: 465 x 450 x 740 mm (18 x 17.7 x 29 inches)Frequency Range: 9 kHz to 30 MHzInductors: 50 Ω // [5 Ω + 50 µH] with 250 µH chokeMains & EUT Connections: 4P5W connectorRF Connector: BNC (f)Standards Met: IEC 60309; UL1682; UL1686; CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461FVoltage Rating: 400 VAC, 565 VDC (L-PE, N-PE) 690 VAC, 975 VDC (L-L, L-N) -
Keysight (Agilent) N9038A-526 MXE EMI Receiver, 3 Hz to 26.5 GHz
SKU: 10259
Frequency Range: 20 Hz - 26.5 GHzResolution: 2 HzBandwidth accuracy (–3.01 dB): 1 Hz to 1.3 MHz ± 2 % (nominal)Dynamic Range: > 70 dBAmplitude Accuracy: < ± 2.7 dBEMC Standards: CISPR 11, CISPR 22, ANSI C63.2Typically In Stock -
Keysight (Agilent/HP) 11947A 9 kHz - 200 MHz Transient Limiter w/ High Pass Filter
SKU: 4602
Applications: Conducted Emissions, Precompliance EMC TestingFrequency Range: 9 kHz to 200 MHzInsertion Loss: 10 dBMax. Input Level: Continuous: 2.5 W (+34 dBm), Pulse: 10 kW for 10 µS, DC:±12 VTypically in Stock -
EM Test CWS 500N2.2 BCI Test System
SKU: sku-252
Test Capabilities: RF Conducted ImmunityStandards Met: MIL STD 461 CS 114, DO-160 CS TestApplications: Vehicle, Military and Aerospace, BCI TestingBCI Test Levels (w/ built-in amplifier): 400mA/114 dBµAFrequency Range (w/ built-in amplifier): 9 kHz - 400 MHzTypically In Stock -
AH Systems PAM-0204 Preamplifier, 20 MHz - 4 GHz, 24 dB
SKU: 10249
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Improve overall system sensitivity for field measurements.Connector: N(f) to N(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 20 MHz - 4 GHzGain: 26 dB typical (22 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 170 mAVSWR: 2.0:1 Input; 1.7:1 Output$550.00Typically In Stock -
PMM (Narda) LP-03 Log Periodic Antenna, 800 MHz - 6 GHz
SKU: 10238
Weight: 0.25 kgs (0.6 LB's)Antenna Factor (1 Meter): 23 / 42 dB typicalAntennas: Log Periodic AntennasApplication/Test Type: Radiated emissions and immunityConnector: Type-N(m) or Type-N(f)Dimensions: 18.7 cm x 32.5 cm x 8.1 cmFrequency Range: 800 MHz to 6 GHzGain: 3.5 to 6.5 dBi typicalImpedance: 50 Ω nominalMaximum Continuous Power: 75 WattsMounting Base: Tripod adapter, suppliedStandards Met: IEC 61000-4-6, MIL-STD-461F, DO-160VSWR: Less than 1.7:1 typical -
AH Systems SAC-210 RF Cable Up to 5 GHz, BNC(m) to BNC(m)
SKU: sku-234
RF Connector: BNC(m) to BNC(m), RG-58 -
Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines
SKU: sku-230
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low currentCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 ΩCurrent Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions)Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB, 10 dB ±1 dB for CDN A501, A701, A801; 80 MHz to 300 MHz 1): 9.5 dB +3 dB / -2 dB 10 dB +3 dB / -2 dB for CDN A501, A701, A801; All other models 10 dB ±1 dBVoltage Rating: AC max. voltage (line to ground): 63V - 160V; DC max. voltage (line to ground): 100V - 250V; Test voltage: 250 V - 400 V DC, 2 sec (refer to data sheet for exact model specifications) -
Teseq CDN S Series Coupling Network for Screened or Coaxial Cables
SKU: 4255
Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHzMains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)RF Connector: BNC 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)$710.00 -
Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines
SKU: sku-228
Weight: 0.5 kg (1.1 LB.'s)Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCommon Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 ΩCurrent Rating: 400 mA (line), 800 mA (pair)Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB;Dimensions: 4.1 x 2.5 x 4.3 inches (10.5 cm x 6.5 cm x 11.0 cm)Frequency Range: 150 kHz to 80 MHz (Optional 10 kHz - 230/300 MHz)Mains & EUT Connections: D-Sub adapter to RJ45 / RJ11 (1 mm banana on certain 10 kHz models)RF Connector: BNC, 50 ΩRF Input Voltage: 20 Volts MaxStandards Met: IEC 61000-4-6Voltage Division Factor: 9.5 dB ±1 dB (10 kHz to 230 MHz: 10 dB ±1 dB)Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M432 32 Amp Coupling/Dcoupling Network
SKU: sku-226
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6Voltage Division Factor: 10 dB +3 dB / -1 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec$270.00