Test Equipment, Systems & Solutions
-
Schwarzbeck BBHA 9120 E Double Ridged Broadband Horn Antenna
SKU: 30148
Nominal Frequency Range: 0.5 GHz to 6 GHzUsable Frequency Range: 0.5 GHz to 8 GHzPolarization: LinearPattern Type: DirectionalIsotropic Gain: 6 to 18 dBiAntenna Factor: 19 to 29 dB/mInquire for Lead Time -
Amplifier Research MT06002 Multi-Tone RF Radiated & Conducted Immunity System
SKU: 11384
Applications: EMC RF/Radiated Susceptibility TestingFrequency Range: 10 kHz to 6 GHzAverage Output Power: 10 dBmMax. Reverse Power: 24 dBmModulation: AM, FM, Pulse, PhaseTest Standards: See in overviewInquire for Availability -
Schwarzbeck BBV 9744 Broadband Preamplifier
SKU: sku-1246
Frequency Range: 9 kHz – 6 GHzNoise figure: typ. 2.5 dB (1.0 GHz)Gain: typ. +28 dBAmplitude flatness: typ. < +/- 3 dBImpedance: 50 ΩVSWR Input / Output typ.: < 2 : 1Power supply: + 10-15 V, 120 mAConnectors: N-Type FlangeInquire for Availability -
Schwarzbeck NNBM 8126-A 890 Single Path Airborne Equipment LISN
SKU: sku-1139
Applications: Conducted Emissions, BCI Testing , Automotive EV EMCTest Standards: CISPR 25, MIL-STD-461, ISO 7637Max EUT DC Voltage: 1,000 VoltsMax EUT Current: 200 AmpsMax EUT AC Voltage (60Hz/400Hz): 400V/300VInductance: 5 µHInquire for Lead Time -
Solar Type 7334-1 Loop Sensor for RE01 and RE101 Magnetic Emission Tests
SKU: sku-499
Weight: 3 pounds (1.36 kg)Antennas: Loop AntennasConnector: BNCConstruction: Shielding: ElectrostaticDimensions: 5.24" diameter (13.3 cm)General Data: Technical Details -
IFI M33 10 kHz to 230 MHz 35 Watt RF Power Amplifier
SKU: sku-467
Max Frequency: 230 MHzMin Frequency: 10 kHzOutput Power: 35 WattsApplications: RF Conducted Immunity, MedicalStandards: IEC 61000-4-6AC Input Power: 100-240V/1PH/300VAGain: 45dB -
AR CI00 Series RF Conducted Immunity Systems
SKU: 10420
Test Capabilities: RF Conducted ImmunityStandards Met: IEC/EN 61000-4-6, CS114, ISO 11452-4, DO-160 CS"Applications: Radiated Immunity Debugging, CE Marking, Medical Devices, Industrial Machinery, Electronics & ITCDN Test Levels (w/ built-in amplifier): 60VrmsBCI Test Levels (w/ built-in amplifier): 400mA/114 dBµAFrequency Range (w/ built-in amplifier): 9 kHz - 1 GHz -
Com-Power CLCI-100 Bulk Current Injection Probe for 10 KHz to 100 MHz
SKU: sku-384
Weight: 4.5 lbs. (2.04 Kg)Aperture: 1.575” (40 mm)Application/Test Type: Conducted and Radiated Susceptibility TestingDimensions: Window Diameter: 1.575” (40 mm) Outside Diameter: 5.75” (146 mm) Width: 2.75” (70 mm)Frequency Range: 10 KHz to 100 MHzRF Connector: N-Type (female)Standards Met: EC 61000-4-6 and CISPR 16-1-2 -
Noiseken ESS-B3011 & GT-30R Electrostatic Discharge Simulator System for up to 30kV Testing
SKU: 345
Weight: Generator : Approx. 4.8kg Discharge gun : Approx. 800g ( excluding cable and connector)Standards Met: IEC 61000-4-2, ISO 10605Air Discharge Voltage Range: 0.20kV30.0kV±5%(30.5kVmax)Battery: AC100V to AC240V ±10% 50Hz/60Hz 62VAContact Discharge Voltage Range: 0.20kV30.0kV±5%(30.5kVmax)Polarity: positive/negativePre-Programmed IEC Levels: YesResolution: Air discharge mode : 2.0kV, 4.0kV, 8.0kV and 15.0kV step Contact discharge mode : 2.0kV, 4.0kV, 6.0kV and 8.0kV stepTypically In Stock -
Teseq CBL 6112D Bilog Antenna, 30 MHz to 2 GHz, 300 Watts CW
SKU: 10112
Impedance: 50 OhmsWeight: approx. 4.2 kg (9.25 LB's)Antenna Factor (1 Meter): 7 to 27 dB/mAntennas: Bilogical AntennasApplication/Test Type: VHF radio approval applications, Compliance Emission TestingConnector: N type femaleDimensions: (L x H x W in mm): approx. 1530 X 1390 X 630Frequency Range: 30 MHz to 2 GHzGain: 6 dB (200 MHz to 700 MHz), 8 dB (700 MHz to 2000 MHz)Impedance-2: 50 ΩMaximum Continuous Power: 300 Watts (80 MHz - 2 GHz)Standards Met: IEC/EN 61000-4-3, CISPR 13, CISPR 14-1, CISPR 16-1-4, CISPR 16-2-3, CISPR 22, CISPR 24, CISPR 32, EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, IEC 60533, IEC 60601-1-2, IEC 61326, ISO 11452-2VSWR: Average 2:1Inquire for Availability -
PMM L3-32 Four Line 3-Phase LISN w/ V-Network, 32 Amps AC+DC
SKU: 8784
Application/Test Type: Measurement on AC 3-phase power circuits from DC to 60 HzCurrent Rating: 32 Amps with IEC plug; 16 Amps with Schuko plugFrequency Range: 9 kHz to 30 MHzInductors: 50 Ω // [5 Ω + 50 µH] with 250 µH chokeMains & EUT Connections: 32 A IEC connector; 16 A SCHUKO connectorRF Connector: BNC (f)Standards Met: VDE 0876, CISPR 16-1-2, FCC Part 15Voltage Rating: 230 Volts AC and 325 Volts DC (Single Phase L-N, L-PE, N-PE and Three Phase L-PE and N-PE); 400 Volts AC and 565 Volts DC (Three Phase L-L, L-N)Additional Standards Met: DO-160F, CISPR 22, ANSI C63.4Typically In Stock -
Haefely PEFT 8010 High Voltage EFT/Burst Generator, 7.3kV
SKU: sku-306
Weight: 14 kgApplication/Test Type: Approval testing, Product development, Post design diagnostics, Industrial, HouseholdBurst (EFT) 5/50 ns: Pulse conforms to IEC/EN 61000-4-4Burst frequency: 1 Hz … 110 kHz (Duration 0.01 - 999 ms)Burst time: 0.1 Hz - 400 Hz; 2.5 ms - 10 s; 1 period - 500 periodsCoupling: Built-in Single Phase AC 264 Volts / 16 Amps 50-60Hz, 10 Amps from 16 - 400 Hz; 125V/10A DC (Modes: L-GND, N-GND, PE-GND, LN-GND, LPEGND, NPE-GND, LNPE-GND)Dimensions: 450mm x 130mm x 570mmGeneral Data: Technical DetailsPolarity: positive / negative / alternatePulse amplitude: 1.0 to 7.3kV (6.6 kV at CDN Output)Repetition time: Impulses per second: max. 250 for Unom over 4 kV; Impulses per burst: max. 500 for Unom 4 kVStandards Met: IEC/EN 61000-4-4 Ed. 1 + 2, IEC 61326, EN 61000-6-1, IEC 61850-3, EN 61000-6-2Supply Voltage: 85 ... 264 VAC, 150 VA, 50 / 60 HzTest duration: 0 s … 8 h per path