Narda PMM EP-602 5 kHz - 9.25 GHz Broadband Active Electric Field Probe
SKU: 5497
Application/Test Type: Monitoring Electric Field StrengthsField Strength Range: 1.5 to 1500 V/m (0.01 V/m)Frequency Range: 5 kHz to 9.25 GHzStandard Met: IEC/EN 61000-4-3Interface: Fiber-OpticBattery Life: 60-80 hoursDynamic Range: 1,5 to 1500 V/m, 60 dB single rangeTypically In Stock -
Com-Power CLA-150 32mm Absorbing Clamp CISPR 14
SKU: 1551
Test: CISPR 14Application/Test Type: Conducted Emissions, Radiated EmissionsClamp factor (CF): -3 dB to +4 dBDimensions: 627 x 114 x 165 mm (24.7 x .4.5 x 6.5 inches)Frequency Range: 30 MHz to 1000 MHzIsolated lines under test: Power supply lines and other connecting linesMax. Cable Diameter: 32 mm (1.26 inches)Min. site attenuation: 14 dB to 21 dBRF Connector: BNC (f), 50 OhmsInquire for Availability -
PMM L3-64/690V 690 Volt LISN for IEC 60309, UL1682, UL1686
SKU: 10264
Weight: 50 kg (110 pounds)Application/Test Type: Ancillary device intended for repeatable and accurate measurement of the disturbance voltage that an EUT (Equipment Under Test) may inject into the power line or mains.Current Rating: 63 Amps Max (IEC60309); 60 Amps Max (UL1682, UL1686)Dimensions: 465 x 450 x 740 mm (18 x 17.7 x 29 inches)Frequency Range: 9 kHz to 30 MHzInductors: 50 Ω // [5 Ω + 50 µH] with 250 µH chokeMains & EUT Connections: 4P5W connectorRF Connector: BNC (f)Standards Met: IEC 60309; UL1682; UL1686; CISPR 16-1-2; VDE 0876; FCC part 15; MIL-STD 461FVoltage Rating: 400 VAC, 565 VDC (L-PE, N-PE) 690 VAC, 975 VDC (L-L, L-N) -
Keysight (Agilent) N9038A-526 MXE EMI Receiver, 3 Hz to 26.5 GHz
SKU: 10259
Frequency Range: 20 Hz - 26.5 GHzResolution: 2 HzBandwidth accuracy (–3.01 dB): 1 Hz to 1.3 MHz ± 2 % (nominal)Dynamic Range: > 70 dBAmplitude Accuracy: < ± 2.7 dBEMC Standards: CISPR 11, CISPR 22, ANSI C63.2Typically In Stock -
Keysight (Agilent/HP) 11947A 9 kHz - 200 MHz Transient Limiter w/ High Pass Filter
SKU: 4602
Applications: Conducted Emissions, Precompliance EMC TestingFrequency Range: 9 kHz to 200 MHzInsertion Loss: 10 dBMax. Input Level: Continuous: 2.5 W (+34 dBm), Pulse: 10 kW for 10 µS, DC:±12 VTypically in Stock -
EM Test CWS 500N4 Common-Mode Disturbance Simulator for IEC 61000-4-16 & IEC 61000-4-19
SKU: sku-254
Weight: Approx. 30kgDimensions: 555mm x 448mm x 286mmFrequency Range: 10Hz to 165kHzMax input power: 600 WattsOutput: For output characteristics reference data sheetSupply Voltage: 115V - 230V +10/-15%, 50/60Hz -
EM Test CWS 500N2.2 BCI Test System
SKU: sku-252
Test Capabilities: RF Conducted ImmunityStandards Met: MIL STD 461 CS 114, DO-160 CS TestApplications: Vehicle, Military and Aerospace, BCI TestingBCI Test Levels (w/ built-in amplifier): 400mA/114 dBµAFrequency Range (w/ built-in amplifier): 9 kHz - 400 MHzTypically In Stock -
AH Systems PAM-0204 Preamplifier, 20 MHz - 4 GHz, 24 dB
SKU: 10249
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Improve overall system sensitivity for field measurements.Connector: N(f) to N(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 20 MHz - 4 GHzGain: 26 dB typical (22 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 170 mAVSWR: 2.0:1 Input; 1.7:1 Output$550.00Typically In Stock -
PMM (Narda) LP-03 Log Periodic Antenna, 800 MHz - 6 GHz
SKU: 10238
Weight: 0.25 kgs (0.6 LB's)Antenna Factor (1 Meter): 23 / 42 dB typicalAntennas: Log Periodic AntennasApplication/Test Type: Radiated emissions and immunityConnector: Type-N(m) or Type-N(f)Dimensions: 18.7 cm x 32.5 cm x 8.1 cmFrequency Range: 800 MHz to 6 GHzGain: 3.5 to 6.5 dBi typicalImpedance: 50 Ω nominalMaximum Continuous Power: 75 WattsMounting Base: Tripod adapter, suppliedStandards Met: IEC 61000-4-6, MIL-STD-461F, DO-160VSWR: Less than 1.7:1 typical -
AH Systems SAC-210 RF Cable Up to 5 GHz, BNC(m) to BNC(m)
SKU: sku-234
RF Connector: BNC(m) to BNC(m), RG-58 -
EM Test (Lüthi) CDN T-Type Coupling/Decoupling Network for Unshielded Lines
SKU: sku-232
Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCurrent Rating: 1.5 Amps (3/5 Amp models available)Frequency Range: 150 kHz to 230 MHz (limited to 80 MHz on 3/5 Amp models)Mains & EUT Connections: Banana, XLR, RJ45, RJ11RF Connector: BNC, 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6Voltage Rating: AC max. voltage (line to ground): 63 Volts DC max. voltage (line to ground): 100 Volts Test voltage: 200 VDC, 2 s -
EM Test (Lüthi) AF-Type Coupling/Decoupling Network for Unscreened/Unsymmetrical Lines
SKU: sku-231
Application/Test Type: Immunity test to conducted disturbances, induced by radio-frequency fields according to the standardsCurrent Rating: 1.5 Amps (Optional 3 Amps)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230/300 MHzMains & EUT Connections: 4 mm banana or D-Sub 15/25 pinsRF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC 61000-4-6, CISPR 15, IEC/EN 60945, EN 55015Voltage Rating: AC max. voltage (line to ground): 63V - 250V; DC max. voltage (line to ground): 100V - 250V;