Categories
Test Equipment, Systems & Solutions
-
Teseq CDN M416 4-Line Coupling/Decoupling Network
SKU: sku-225
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type
SKU: sku-224
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dBDimensions: 4.1 x 3 x 5 inches (10.5 x 7.5 x 12.5 cm)Frequency Range: 150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)Insertion Loss: Greater than 0.1 dBMains & EUT Connections: 4 mm, safety (Optional IEC 320 16A)RF Connector: BNC, 50 ΩRF Input Voltage: Less than 30 VStandards Met: IEC 61000-4-6, CISPR 16-1-2, CISPR 16-2-1 and CISPR 15Voltage Division Factor: 20 dB ±1.5 dBVoltage Rating: AC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec -
Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port
SKU: sku-223
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dBDimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBMains & EUT Connections: AE Euro: IEC 60320 C14 EUT-socket 2lines: CEE 7/17;RF Connector: BNC 50 ΩRF Input Voltage: 30 Volts MaxStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dBVoltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec$1,020.00 -
Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines
SKU: sku-222
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 ADimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)Frequency Range: 150 kHz to 230 MHzInsertion Loss: Less than 0.1 dBRF Connector: BNC 50 ΩRF Input Voltage: Less than 20 VoltsStandards Met: IEC/EN 61000-4-6Voltage Division Factor: 10 dB ±1 dBVoltage Rating: 3 kV DC, 2 sec$790.00 -
Teseq CDN 3083-Surge 620 Volt, 100-200 Amp Manual Coupler
SKU: sku-220
Weight: 80 kg (176 LB's)Application/Test Type: Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)Current Rating: 100 Amp or 200 Amp continous depending on modelDimensions: 850 x 520 x 345 mmMains & EUT Connections: Fischer 105 series; Screw terminals, rated for 230 ARF Input Voltage: Max. 8 kV / 4 kAStandards Met: IEC / EN 61000-4-5:2005, ANSI C62.45 standard, in IEC / EN 61000-4-12:2006 and ANSI C62.41Voltage Rating: 620 VAC RMS L-to-L (max. 440 V for NSG 3040 and Modula); 620 VAC RMS L-to-PE (max. 440 V for NSG 3040 and Modula); 620 VDC -
AH Systems PAM-1840VH High Gain Broadband Preamplifier, 18 - 40 GHz
SKU: sku-213
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Overcome attenuation problems at higher frequencies. Match to double ridge guide horn antenna.Connector: 2.9mm(f) to 2.9mm(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 18 GHz - 40 GHzGain: 37 dB typical (33 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 275 mAMaximum Continuous Power: +8 dBm @ 1 dB compressionVSWR: less than 2.9:1 typical -
AH Systems PAM-1840 High Frequency Broadband Preamplifier, 18 - 40 GHz
SKU: sku-212
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Overcome attenuation problems at higher frequencies.Connector: 2.9mm(f) to 2.9mm(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 18 GHz - 40 GHzGain: 20 dB typical (15 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 170 mAMaximum Continuous Power: +6 dBm @ 1 dB compressionVSWR: less than 1.7:1 typical -
AH Systems PAM-1826 High Frequency Preamplifier, 18 - 26.5 GHz
SKU: sku-211
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: EMI Precompliance Testing Emissions Measurements, CE MarkingConnector: SMA(f) to SMA(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 18 GHz - 26.5 GHzGain: 32 dB typicalInput: 100/220 VAC regulated P/S output: 12 VDC 170 mAMaximum Continuous Power: +6 dBm @ 1 dB compressionVSWR: 1.7:1 typicalEMC Standards: CISPR 11, CISPR 32, FCC Part 15 -
AH Systems PAM-0118P Broadband Preamplifier, 20 MHz - 18 GHz
SKU: 2669
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Improve overall system sensitivity for field measurements.Connector: N(f) to N(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 20 MHz - 18 GHzGain: 37 dB typicalInput: 100/220 VAC regulated P/S output: 12 VDC 170 mAMaximum Continuous Power: + 10 dBm @ 1 dB compressionVSWR: 2.5:1 typicalInquire for Availability -
AH Systems PAM-0207 Preamplifier, 20 MHz - 7 GHz
SKU: 10209
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Improve overall system sensitivity for field measurements.Connector: N(f) to N(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 20 MHz - 7 GHzGain: 30 dB typical (25 dB minimum)Input: 100/220 VAC regulated P/S output: 12 VDC 170 mAMaximum Continuous Power: + 3 dBm @ 1 dB compressionVSWR: 2.2:1 Input; 1.8:1 Output -
AH Systems CPF-532 Calibration Fixture for Injection & Monitoring Current Probes
SKU: sku-207
Weight: 13 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 12" x 7" x 8"Frequency Range: 10 kHz - 400 MHz -
AH Systems CPF-531 Calibration Fixture for RF Current Probes
SKU: sku-206
Weight: 10 Lb.'sApplication/Test Type: Keep your broadband Current Probes, and Injection Current Probes calibratedDimensions: 10" x 7" x 7"Frequency Range: 1 MHz - 1 GHz