Test Equipment
-
Teseq CDN AF Series Coupling/Decoupling Network for Unscreened/Unbalanced Lines
SKU: sku-230
Weight: 1.5 kg (3.3 lbs)Application/Test Type: Coupling / decoupling network (CDN) used for all unscreened, unbalanced lines, carrying low currentCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 2300 MHz: 150 Ω +60 Ω / -45 Ω; 230 MHz to 300 MHz 1): 150 Ω +60 Ω / -60 ΩCurrent Rating: 200 mA to 4 Amps (refer to data sheet for exact model specifications)Decoupling of Common Mode Disturbance: 10 kHz: Over 10 dB:150 kHz: Over 35 dB: 26 MHz: Over 45 dB: 80 MHz: Over 25 dB;150 kHz: Over 30 dB: 1.5 MHz: Over 60 dB: 30 MHz: Over 50 dB: 230 MHz: Under 30 dB (refer to data sheet for some exceptions) -
Teseq CDN S Series Coupling Network for Screened or Coaxial Cables
SKU: 4255
Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cablesCommon Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 250 mA (CDN ST08 1 Amp)Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz$710.00 - $2,110.00 -
Teseq CDN T Series Coupling Network for Unscreened Communication/Data Lines
SKU: sku-228
Weight: 0.5 kg (1.1 LB.'s)Application/Test Type: EMC testing for unscreened data communication/telecom lines (Power over Ethernet, 1100BaseT4, 100Base VG-AnyLan, 1000BaseT, Token ring, ISDN, 10BaseT, 100BaseTX, ATM, FDDI, TP-PMDCommon Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 Ω; 80 MHz to (230) 300 MHz: 150 Ω +60 Ω / -60 ΩCurrent Rating: 400 mA (line), 800 mA (pair)Decoupling of Common Mode Disturbance: 10 kHz: Over 20 dB; 1.5 MHz / 30 MHz: Over 55 dB; 80 MHz: Over 45 dB; 230 MHz: Over 35 dB; -
Teseq CDN M5 5-Line Coupling Network for AC Power Lines, 16-32 Amps
SKU: sku-227
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dB -
Teseq CDN M432 32 Amp Coupling/Dcoupling Network
SKU: sku-226
Weight: 6.5 kg (14.3 LB.'s)Application/Test Type: 4 mains AC power lines emissions testing up to 32 Amps (2L+N+PE), (3L+PE), optional (3L+N)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 32 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dB$270.00 -
Teseq CDN M416 4-Line Coupling/Decoupling Network
SKU: sku-225
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dB -
Teseq CDN M316 Coupling/Decoupling Network (CDN) CDN M3 Type
SKU: sku-224
Weight: 700 grams (1.5 LB.'s)Application/Test Type: 3 power lines, (L+N+PE), (2L+PE), (Optional L+L+L)Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dB -
Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port
SKU: sku-223
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB$1,020.00 - $1,445.00 -
Teseq CDN M1-10 Coupling Network 10 KHz to 80 MHz for PE Lines
SKU: sku-222
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 10 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 80 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: Current max. (no saturation): 300 mA; Current max. (1 s for PE line test): 25 ADimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)$790.00 -
Teseq CDN 3083-Surge 620 Volt, 100-200 Amp Manual Coupler
SKU: sku-220
Weight: 80 kg (176 LB's)Application/Test Type: Manual Surge Testing for EUT up to 100Amps, 620 VAC; Three phase (5 wire); Two phase (4 wire); Single phase (3 wire)Current Rating: 100 Amp or 200 Amp continous depending on modelDimensions: 850 x 520 x 345 mmMains & EUT Connections: Fischer 105 series; Screw terminals, rated for 230 A -
AH Systems PAM-1840VH High Gain Broadband Preamplifier, 18 - 40 GHz
SKU: sku-213
Weight: 1.1 lbs. / 0.5 kgApplication/Test Type: Overcome attenuation problems at higher frequencies. Match to double ridge guide horn antenna.Connector: 2.9mm(f) to 2.9mm(f)Dimensions: 2.5" x 3.75" x 6.25" (63mm x 95mm x 158mm)Frequency Range: 18 GHz - 40 GHz -
AH Systems PAM-1840 High Frequency Broadband Preamplifier, 18 - 40 GHz
SKU: sku-212