(Showing 12 of 1980)
Show 12 24 36 48 96

Categories

Test Equipment, Systems & Solutions

  • PMM (Narda) EMR-300 Broadband RF Survey Meter, 3 kHz to 60 GHz

    SKU: sku-611

    Weight: 450 g
    Application/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.
    Battery: 2 ea. AA type, re-chargeable batteries
    Dimensions: 96x64x465 mm
    Frequency Range: varies on probe
    Operation Time: 8 hours (typical)
    Probe Holder Tip: BNC
    Recharging Time: re-charged via supplied charger
    RF Field Probes: E-Field
    Standards Met: IEC/EN 61000-4-3
  • Amplifier Research 20S1G4 Solid State RF Amplifier

    SKU: sku-610

    Weight: 37 lbs
    Dimensions: 19.8 x 6.1 x 14.8 in
    Flatness: ± 1.5 dB
    Frequency Range: 0.7–4.2GHz instantaneously
    Gain: (at maximum setting) 43 dB minimum (Continuous Range) 10 dB minimum
    Harmonic Distortion (THD): Minus 20 dBc maximum at 15 watts
    Impedance: 50 ohms, VSWR 2.0:1 maximum
    Input: 90-132, 180-264 VAC 50/60 Hz, single phase 210 watts maximum
    Output: POWER OUTPUT @ 3dB COMPRESSION Nominal 25 watts Minimum 20 watts POWER OUTPUT @ 1dB COMPRESSION Nominal 22 watts Minimum 18 watts
    RF Connector: RF Connector Type N female REMOTE INTERFACES: IEEE-488-24 pin female RS-232-9 pin Subminiature D (female) RS-232 (fiber optic)-Type ST USB 2.0-Type B Ethernet-RJ-45
    RF Input Voltage: 1.0 milliwatt maximum for rated output
    Standards Met: CE Mark Testing
    Call for availability
  • Com-Power LI-3P-1100 150 kHz - 30 MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-600

    Weight: 71.5 lbs
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 100 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
  • Com-Power LI-3P-163 150kHz - 30MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-599

    Weight: 52.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 63 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
  • Com-Power LI-3P-116 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network

    SKU: sku-597

    Weight: 27.5 lbs.
    Application/Test Type: Power Line Conducted Emissions Tests
    Current Rating: 16 Amperes
    Frequency Range: 150 kHz to 30 MHz
    Inductors: 50 µH
    Insertion loss: less than 0.7 dB
    Isolation: more than 40 dB
    Mains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power Jack
    RF Connector: RF Measurement Port 50Ω - N-Type (female)
    Standards Met: ANSI C63.4, CISPR 16-1-2
    Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V
    CISPR 16-1-2: Yes
    DO-160F: Yes
    CISPR 22: Yes
    FCC: Yes
    ANSI C63.4: Yes
    $395.00
  • 3ctest MFS Series Magnetic Field Simulator for IEC 61000-4-8

    SKU: sku-594

    Weight: Approx. 35Kg+68Kg
    Coil Factor: 1000 x 1000mm
    CRO Trigger: Automatic, manual or external signal trigger
    Dimensions: 19 inch/6U/4U
    Magnetic Field Strength: varies per coil: TCXS111 single turn1m*1m square coil: 1-100A/m continuous, 100-400A/m(1-10 short time) TCXS113three-turn 1m*1m square coil: 1-300A/m continuous, 300-1200A/m 1~10s short time
    Max input power: 100W
    Output Current: 50Hz/60Hz sine wave +/- 5%
    Repetition time: 1-9999s
    Standards Met: IEC/EN 61000-4-8, GB/T 17626.8
    Test duration: 1-28800s
    Generic Standards: IEC 61000-6-1, IEC 61000-6-2
    6-8 Weeks
  • 3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection

    SKU: sku-591

    Weight: 40Kg
    Communication: Ethernet LAN、RJ45
    Coupling: BNC
    Dimensions: 19 inch/6U
    Dips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29
    Frequency: 45-65Hz
    General Data: Technical Details
    Input: BNC,5V TTL
    Mains & EUT Connections: 4mm banana line
    Maximum Continuous Power: 100W
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Phase synchronization: 0°- 360°,1° step or random
    Repetition time: 0.3-9999 cycle or 5ms-9999ms
    Rise time: 1-5us(100Ω load)
    Supply Voltage: 110V/220V, ±10%, 50/60Hz
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
  • 3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11

    SKU: sku-590

    Mains & EUT Connections: 4mm banana line
    Output Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3s
    Peak inrush current capability: 500 Amps
    Rise time: 1-5us(100Ω load)
    Test duration: 50ms-50000ms
    Test Voltage: 250V AC,300V DC
    Trigger: BNC,5V TTL
    Inquire for Availability
  • 3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A

    SKU: sku-588

    Test voltage: Voltage drop: 1V max@30A
    Weight: 20 kg
    Dimensions: 19" / 4 U
    Output: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal output
    Peak current: 60A duration time 500 ms
    Pulse duration: Drop duration time td 1us - 10 s
    Repetition rate: 100 ms - 999s
    Source Impedance: High resistance or low resistance
    Test Voltage: 0–60 V
    Trigger: External trigger signal by oscilloscope, BNC,5V TTL
    Trigger of bursts: Automatic, manual, external
  • Amplifier Research (AR) 40WD1000, DC - 1000 MHz RF Power Amplifier, 40 Watt CW

    SKU: sku-587

    Weight: 64 lb
    Communication: Remote control: 25 Pin Subminiature D on rear panel
    Dimensions: 19.8 x 9.8 x 18.0 in
    Flatness: ±1.0 dB typical ±1.5 dB maximum
    Frequency Range: DC-1000 MHz
    Gain: 47 dB minimum
    Impedance: INPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum OUTPUT IMPEDANCE: 50 ohms, nominal
    Input: 90 to 132; 180 to 264 VAC 50/60 Hz, single phase 700 watts maximum
    Output: 40 watts minimum
    RF Connector: Type N female on front panel
    RF Input Voltage: 1.0 milliwatt maximum for rated output

Connect with The EMC Shop

Our experienced staff can help you with applications, purchase and rental options.