PMM (Narda) EMR-300 Broadband RF Survey Meter, 3 kHz to 60 GHz
SKU: sku-611
Weight: 450 gApplication/Test Type: Monitoring electric field strengths in GTEM's, Anechoic Chambers and other RF rooms for radiated immunity testing.Battery: 2 ea. AA type, re-chargeable batteriesDimensions: 96x64x465 mmFrequency Range: varies on probeOperation Time: 8 hours (typical)Probe Holder Tip: BNCRecharging Time: re-charged via supplied chargerRF Field Probes: E-FieldStandards Met: IEC/EN 61000-4-3 -
Amplifier Research 20S1G4 Solid State RF Amplifier
SKU: sku-610
Weight: 37 lbsDimensions: 19.8 x 6.1 x 14.8 inFlatness: ± 1.5 dBFrequency Range: 0.7–4.2GHz instantaneouslyGain: (at maximum setting) 43 dB minimum (Continuous Range) 10 dB minimumHarmonic Distortion (THD): Minus 20 dBc maximum at 15 wattsImpedance: 50 ohms, VSWR 2.0:1 maximumInput: 90-132, 180-264 VAC 50/60 Hz, single phase 210 watts maximumOutput: POWER OUTPUT @ 3dB COMPRESSION Nominal 25 watts Minimum 20 watts POWER OUTPUT @ 1dB COMPRESSION Nominal 22 watts Minimum 18 wattsRF Connector: RF Connector Type N female REMOTE INTERFACES: IEEE-488-24 pin female RS-232-9 pin Subminiature D (female) RS-232 (fiber optic)-Type ST USB 2.0-Type B Ethernet-RJ-45RF Input Voltage: 1.0 milliwatt maximum for rated outputStandards Met: CE Mark TestingCall for availability -
Teseq PMU 6003 USB Power Meter/Sensor 9 kHz - 3 GHz
SKU: sku-606
Current rating: 100 mA at 5 VFrequency Range: 9 kHz – 3 GHzRF Connector: N male 50 ΩStandards Met: IEC/EN 61000-4-3 IEC/EN 61000-4-6Supply Voltage: min. 4.7 V / max. 9 V -
3ctest TCXS111 Power Frequency Magnetic Field Coil for IEC61000-4-8, -9, -10
SKU: sku-602
# of turns: singleDimensions: 1000*1000mm - Length*WidthMagnetic Field Strength: 1A/m ~ 400A/mStandards Met: IEC 61000-4-8, IEC 61000-4-9, IEC 61000-4-10Generic Standards: IEC 61000-6-1, IEC 61000-6-24-6 Weeks -
Com-Power LI-3P-1100 150 kHz - 30 MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-600
Weight: 71.5 lbsApplication/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 100 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-163 150kHz - 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-599
Weight: 52.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 63 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V -
Com-Power LI-3P-116 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-597
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VCISPR 16-1-2: YesDO-160F: YesCISPR 22: YesFCC: YesANSI C63.4: Yes$395.00 -
3ctest MFS Series Magnetic Field Simulator for IEC 61000-4-8
SKU: sku-594
Weight: Approx. 35Kg+68KgCoil Factor: 1000 x 1000mmCRO Trigger: Automatic, manual or external signal triggerDimensions: 19 inch/6U/4UMagnetic Field Strength: varies per coil: TCXS111 single turn1m*1m square coil: 1-100A/m continuous, 100-400A/m(1-10 short time) TCXS113three-turn 1m*1m square coil: 1-300A/m continuous, 300-1200A/m 1~10s short timeMax input power: 100WOutput Current: 50Hz/60Hz sine wave +/- 5%Repetition time: 1-9999sStandards Met: IEC/EN 61000-4-8, GB/T 17626.8Test duration: 1-28800sGeneric Standards: IEC 61000-6-1, IEC 61000-6-26-8 Weeks -
3ctest PFS 2216SVD Single Phase Power Fail Simulator w/ Two Semiconductor Switches for High Current Protection
SKU: sku-591
Weight: 40KgCommunication: Ethernet LAN、RJ45Coupling: BNCDimensions: 19 inch/6UDips, Interrupts & Variations: Conforms to IEC/EN 61000-4-11, IEC/EN 61000-4-29Frequency: 45-65HzGeneral Data: Technical DetailsInput: BNC,5V TTLMains & EUT Connections: 4mm banana lineMaximum Continuous Power: 100WOutput Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3sPeak inrush current capability: 500 AmpsPhase synchronization: 0°- 360°,1° step or randomRepetition time: 0.3-9999 cycle or 5ms-9999msRise time: 1-5us(100Ω load)Supply Voltage: 110V/220V, ±10%, 50/60HzTest duration: 50ms-50000msTest Voltage: 250V AC,300V DCTrigger: BNC,5V TTL -
3ctest PFS 2216SD Power Fail Simulator for EN/IEC 61000-4-11
SKU: sku-590
Test Standards: IEC/EN 61000-4-11, IEC/EN 61000-4-29Mains & EUT Connections: 4mm banana lineOutput Current: 16A AC/DC continuous current; 20A continuous 5s 40Acontinuous 3sPeak inrush current capability: 500 AmpsApplications: EMC Precompliance Testing, Conducted ImmunityRise time: 1-5us(100Ω load)Test duration: 50ms-50000msTest Voltage: 250V AC,300V DCTrigger: BNC,5V TTLInquire for Availability -
3ctest PFS 6030A Power Failure Simulator for Voltage Dips & Drops,60 V / 30 A
SKU: sku-588
Test voltage: Voltage drop: 1V max@30AWeight: 20 kgDimensions: 19" / 4 UOutput: DUT voltage monitoring output: BNC,10:1 coaxial terminal output DUT current monitoring output: BNC,10A:1V coaxial terminal outputPeak current: 60A duration time 500 msPulse duration: Drop duration time td 1us - 10 sRepetition rate: 100 ms - 999sSource Impedance: High resistance or low resistanceTest Voltage: 0–60 VTrigger: External trigger signal by oscilloscope, BNC,5V TTLTrigger of bursts: Automatic, manual, external -
Amplifier Research (AR) 40WD1000, DC - 1000 MHz RF Power Amplifier, 40 Watt CW
SKU: sku-587
Weight: 64 lbCommunication: Remote control: 25 Pin Subminiature D on rear panelDimensions: 19.8 x 9.8 x 18.0 inFlatness: ±1.0 dB typical ±1.5 dB maximumFrequency Range: DC-1000 MHzGain: 47 dB minimumImpedance: INPUT IMPEDANCE: 50 ohms, VSWR 2.0:1 maximum OUTPUT IMPEDANCE: 50 ohms, nominalInput: 90 to 132; 180 to 264 VAC 50/60 Hz, single phase 700 watts maximumOutput: 40 watts minimumRF Connector: Type N female on front panelRF Input Voltage: 1.0 milliwatt maximum for rated output