(Showing 12 of 1974)
Show 12 24 36 48 96

Categories

Test Equipment, Systems & Solutions

  • E&I / ENI 2100L RF Power Amplifier 10 kHz - 12 MHz, 100 Watts

    SKU: sku-844

    Connectors: BNC
    Cooling: Forced Air
    Flatness: ± 1.5 dB
    Frequency range: 10 kHz - 12 MHz
    Gain: 50 dB nominal
    Gain Flatness: +/- 1.5 dB
    Input: 104-240 Volts
    Input Power for Rated Pout: 0 dBm (1 mW)
    Output: 100 Watts P1dB
    Protection: Unit will withstand input signal of +13 dBm without damage (1.0 V rms) max.
    Rated Power: 100 Watts P1dB Compression
    RF Input Signal: AM, FM, SSB, Pulsed
    RF Input Voltage: 1 mW
    $795.00 - $10,950.00
    In Stock
  • Teseq CDN S900S RS-232 Coupling Decoupling Network for IEC 61000-4-6

    SKU: 10828

    Weight: 1.5 kg (3.3 lbs)
    Application/Test Type: Coupling / decoupling network (CDN) for screened data/telcom lines or coaxial cables
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 250 mA (CDN ST08 1 Amp)
    Decoupling of Common Mode Disturbance: 150 kHz: Over 60 dB; 1.5 MHz: Over 60 dB; 30 MHz: Over 50 dB; 230 MHz: Over 40 dB (refer to data sheet for some exceptions)
    Dimensions: 4 x 4 x 9.5 inches (10 cm x 10 cm x 24 cm); (CDN HDMI and CDN S752A: 28.8 cm 11 inches)
    Frequency Range: 10 kHz to 80 MHz or 150 kHz to 230 MHz
    Mains & EUT Connections: BNC 50 Ω, N 50 Ω, BNC 75 Ω, N 75 Ω, XLR 3 pins, DIN 5 pins, RJ45, D-Sub 9 pins, D-Sub 15 pins, D-Sub 25 pins, HDMI (refer to data sheet for exact model specifications)
    RF Connector: BNC 50 Ω
    RF Input Voltage: 20 Volts Max
    Standards Met: IEC 61000-4-6, CISPR 22, IEC 60601-1-2
    Voltage Division Factor: 9.5 dB to 10 dB ±1 dB (refer to data sheet for some exceptions)
    Voltage Rating: AC max. voltage (line to ground): 100 V - 250V; DC max. voltage (line to ground): 150 V - 400 V; Test voltage: 200 V - 750 V DC, 2 sec (refer to data sheet for exact model specifications)
    $1,190.00
  • Teseq CDN M016 Switchable 16 Amp Coupling/Decoupling Network

    SKU: 10827

    Associated Equipment: RF Conducted Immunity Test Systems
    Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)
    Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
    Current Rating: 16 Amps
    Decoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB
    Dimensions: 3.9" x 3.9" x 9.5" (100 mm x 100 mm x 240 mm)
    Frequency Range: 150 kHz to 230 MHz
    Insertion Loss: Less than 0.1 dB
    Mains & EUT Connections: 4 mm banana
    RF Connector: BNC 50 Ω
    RF Input Voltage: 30 Volts (Max)
    Standards Met: IEC/EN 61000-4-6
    Voltage Division Factor: 150 kHz to 80 MHz: 9.5 dB ±1 dB 80 MHz to 230 MHz: 9.5 dB +3 dB / -2 dB
    Voltage Rating: AC max. voltage (line to ground): 250 V DC max. voltage (line to ground): 400 V; 3 kV DC, 2 sec
    $195.00 - $495.00
    Typically In Stock
  • Fischer F-35A 100 Hz – 108 MHz Current Monitor Probe

    SKU: 1819

    Aperture: 32 mm
    Connector type: Type-N
    Dimensions: Internal diameter: 32 mm External diameter: 98 mm Height: 38 mm
    Frequency range: 100 Hz – 100 MHz
    General Data: Technical Details
    High frequency 3dB cut-off: 108 MHz
    Low frequency 3dB cut-off: 100 Hz
    Maximum peak current: 100 Amps
    Output resistance: 50 Ohms
    Probes: Current monitoring
    $195.00 - $395.00
    In Stock