MIL-STD-461 CS114

(Showing 9 of 9)

The EMC Shop stocks the test equipment and setup materials to perform ideal test and measurements to MIL-STD-461 CS114. Rentals typically ship the same day.

CS114 Conducted Susceptibility, Bulk Cable Injection (BCI)

The MIL-STD-461 CS114 test procedure is used to verify the ability of the EUT to withstand RF signals coupled onto EUT associated cabling. The MIL-STD-461 CS114 requirement is applicable from 10 kHz to 200 MHz for all interconnecting cables, including power cables.

MIL-STD-461 CS114 TEST SETUP

Test Setup Diagram for MIL-STD-461 CS116

MIL-STD-461 CS114 REQUIRED TEST EQUIPMENT

  1. Measurement receivers
  2. Current injection probes (maximum and minimum insertion loss shown on Figure CS114-2)
  3. Current probes
  4. Calibration fixture: coaxial transmission line with 50 ohm characteristic impedance, coaxial connections on both ends, and space for an injection probe around the center conductor.
  5. Directional couplers
  6. Signal generators
  7. Attenuators, 50 ohm
  8. Coaxial loads, 50 ohm
  9. Power amplifiers
  10. LISN

MIL-STD-461 CS114 Test Equipment, Systems & Solutions

Connect with The EMC Shop