RF Power Line CDN's Test Equipment
-
Teseq CDN M210B Coupling Network with CEE 7/17 EUT Port & IEC 60320 C14 AE Port
SKU: sku-223
Weight: 3.3 Lbs (1.5 kg)Application/Test Type: switchable 2 or 3 power lines, (L+N or L+N+PE)Common Mode Impedance: 150 kHz to 26 MHz: 150 Ω ±20 Ω 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: 150 kHz: Greater than 30 dB 1.5 MHz: Greater than 60 dB 30 MHz: Greater than 40 dB 230 MHz: Greater than 20 dB$1,020.00 - $1,445.00 -
Com-Power CDN-M325E 150 kHz - 230 MHz 3-Line RF Coupling Decoupling Network
SKU: 4845
EMC Standard: IEC/EN 61000-4-6Application/Test Type: Three conductor power cableAssociated Equipment: RF Conducted Immunity Test SystemsCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Typically In Stock -
Teseq CDNE M310 Coupling/Decoupling Network for Emission Measurement, 10 A, 30 to 300 MHz
SKU: sku-87
Weight: 700 grams (1.5 LB.'s)Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency rangeCommon Mode Impedance: Common mode impedance (EUT port): 150 Ω +10/-20 ΩCurrent Rating: 10 AmpsDecoupling of Common Mode Disturbance: Greater than 30 dB -
Teseq CDN M216 1kV CDN for CISPR 16-1-2, CISPR 16-2-1 and CISPR 15
SKU: sku-86
Weight: 700 grams (1.5 LB.'s)Application/Test Type: Emission measurement (CDNE) to measure disturbance voltages in the 30 to 300 MHz frequency range.Common Mode Impedance: 150 Ω +10/-20 ΩCurrent Rating: 10 Amps MaximumDecoupling of Common Mode Disturbance: Greater than 30 dB -
Com-Power CDN-M225E Coupling Decoupling Network for Unscreened Power Supply Lines
SKU: sku-54
Weight: 5 lbs. 2.3 kgApplication/Test Type: two conductor power cableCommon Mode Impedance: 150 kHz - 26 MHz: 150Ω ± 20Ω 26 MHz - 80 MHz: 150Ω + 60Ω / – 45Ω 80 MHz - 230 MHz: 150Ω + 60Ω / – 60ΩCurrent Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE) -
Schwarzbeck CDN M4PE 32A Coupling Decoupling Network
SKU: 6657
Frequency Range: 150 kHz to 230 MHzCommon Mode Impedance: 150 kHz – 24 MHz: 150 Ω ±20 Ω, 24 MHz–80 MHz: 150 Ω +60 Ω/-45 Ω, 80 MHz–230 MHz: 150 Ω ±60 ΩMax. RF Test Voltage: 30 VRF Input Power: 6 WInput voltage EuT (AE): Line to ground / line to line: 500 VAC / 1000 VDC, 1000 VAC / 2000 VDC$295.00 - $3,095.00Typically In Stock -
3cTest SEPN 4532Ta CDN for EFT/Burst, Surge, and Ring Wave Immunity Testing
SKU: 30186
Applications: Power LinesTest Standards: EN/IEC 61000-4-12, IEC 61000-4-4, IEC 61000-4-5Input Voltage: AC 100V to 240 V, 50/60 HzCoupling Voltage: 6 kV max.Coupling Current: 3 kA max.Inquire for Lead Time -
Com-Power CDN-M525E 5-Line Coupling Decoupling Network for Unscreened Power Lines
SKU: 10475
Current Rating: 25 Amps AC / 17 Amps DC (Max)Decoupling of Common Mode Disturbance: ≥ 40dB (EUT/AE)Frequency Range: 150 kHz to 230 MHzMains & EUT Connections: 4 mm shrouded banana socketsRF Connector: 50 Ω BNC (Female)$589.00 - $3,275.00In Stock