Test Equipment
-
Narda PMM Rad-IS RF Radiated Immunity System for IEC/EN 61000-4-3
SKU: 10419
Application/Test Type: EMC RF/Radiated Susceptibility TestingConnector: BNC Input, Output Type N(f)Frequency Range: 9 kHz to 3 GHzImpedance: 50 OhmsInput: 115/230 V 50/60 Hz -
Inquire for Availability
-
-
-
EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
SKU: sku-410
Weight: 17 kg (37.5 Pounds)Application/Test Type: Create and output RF currents as well as measure input for CDN and clamp calibration as well as current monitor for clamp applicationsDimensions: 19"/3 HUFrequency Range: Sinus (CW) 100kHz to 300MHz Frequency bands 100kHz to 9.999MHz 10MHz to 99.99MHz 100MHz to 300MHzImpedance: 50 OhmsInquire for Availability -
EM Test TSS 500N10 Telecom Surge Generator ITU-T for Enhanced Level Testing up to 10 kV
SKU: sku-403
Weight: approx. 37.1 kg (81.8 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/9 HU, 420 mm x 448 mm x 500 mmEnergy Storage Capacitor: 1 uF (Pulse 1.2/50 us) 20 uF (Pulse 10/700 μs) 20 uF (Surge Pulse B)Front Time: 1 us ± 30% (Pulse 1.2/50 us) 10 us ± 30% (Pulse 10/700 μs) 9 us ± 30% (Surge Pulse B) -
EM Test TSS 500N4 Telecom Surge Generator as per ITU / FCC up to 4 kV
SKU: sku-402
Weight: approx. 20 kg (44 lbs.)AC Power Adapter: Supply voltage 115/230 V +10/-15%Dimensions: 19"/3HUStandards Met: IEC 61000-4-5 ITU-T K.17 ITU-T K.20 ITU-T K.28 ITU-T K.45 (and more)Voltage Rating: 160 V - 4,000 V ±10% -
Dressler T4 CDN for Unshielded Symmetrical Telecom Lines 150 kHz-230 MHz
SKU: sku-401
Weight: 2.3 Lbs (1.04 kg)Application/Test Type: For CDN disturbing signals to an unscreened cable with balanced linesCurrent Rating: 2 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHz -
EM Test (Lüthi) CDN S1 for 50 kHz to 230 MHz
SKU: sku-400
Weight: 2.0 lbsApplication/Test Type: Coupling/decoupling networks for Conducted immunity, screened lines (coaxial cable)Current Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 4.25 inchesFrequency Range: 150 kHz to 230 MHz -
Dressler S1 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-399
Weight: 1.9 Lbs (0.86 kg)Application/Test Type: For coupling and decoupling of interference signals on screened linesCurrent Rating: 1.5 AmpsDimensions: 7.25 x 4.25 x 5.75 (inches)Frequency Range: 150 kHz to 230 MHz -
Dressler AF4 Coupling/Decoupling Networks (CDN) 150 kHz-230 MHz
SKU: sku-398
Weight: 3.3 Lbs (1.5 kg)Current Rating: 2 AmpsFrequency Range: 150 kHz to 230 MHzRF Connector: BNCStandards Met: IEC/EN 61000-4-6 -
Radiated Immunity Test System for IEC 61000-4-20 TEM Waveguides
SKU: 10393
Application/Test Type: Radiated Susceptibility TestingFrequency Range: 30 to 1000 MHzMax Radiated Field Strength: Lowest field strength: 1 V/m at 600 mm septum height* Highest field strength: approx. 18 V/m at 600 mm septum height*Maximum Continuous Power: Lowest forward power: 15 dBm* Highest forward power: 41 dBm*Test Standards: MIL-461 RS103, IEC/EN 61000-4-3, ISO 11452-2, DO-160 Section 20