ANSI/IEEE Standards Categories
ANSI/IEEE Standards Test Equipment, Systems & Solutions
-
Haefely PIM 100 Combination Wave Impulse Module
SKU: 10297
Output: Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse) up to 7.8kVCoupling (Max EUT Power): 3 Phase - 100 Amps, 690 VACTest Standards: IEC/EN 61000-4-5 Ed. 1 & 2, ANSI C62.45Applications: Surge immunity - Combo Wave, Ring Wave and Oscillatory Waves, EMC Precompliance TestingPulse current (short circuit): 0.1 – 3.7 kA ±10% (8 us ±20% risetime)Pulse repetition: 10 seconds / 6 per minuteFeatures: Impulse voltage and current monitorsIn Stock -
Teseq NNB 51 Line Impedance Stabilization Network Dual-Line-V-LISN
SKU: 10154
Weight: 12 kg (26.5 pounds)Application/Test Type: Measure distortion signals on power mains, EMC Precompliance, Conducted EmissionsCurrent Rating: 16 Amps MaxFrequency Range: 9 kHz to 30 MHzRF Connector: N femaleRF Input Voltage: 250 Volts maxStandards Met: CISPR 16-1-2, MIL-STD-461, FCC Part 15, ANSI C63.4RENTAL ONLY -
FCC-LISN-50-50-4-02 Line Impedance Stabilization Network
SKU: 12364-1
EUT Current Handling: 32 AmpsEUT Voltage Handling: 540V/260VApplications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITServices Available: ISO 17025 Calibration, Rentals, Leases, Purchases, Repairs, Eval/CharacterizationTest Standards: ISO 60601-1-2, FCC Part 15Additional Test Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD-461Inductance: 5 µHInquire for Availability -
Thermo Keytek E510A 10kV Surge Generator
SKU: 10799
Standards Met: ANSI/IEEE C62.41 Cat. B and IEC 61000 4-5Phase synchronization: ±15° with optional coupler/decouplerPulse current (short circuit): 8/20µs, 0-5.05kA with 2 ohm effective source impedance, ±10%Pulse repetition: 1 shot/18 secondsPulse voltage (open circuit): 1.2/50µs, 0-10.1kV ±10% in 1 volt stepsRepetition time: Adjustable from 300ms to 5s; 1ms resolutionTypically In Stock -
Thermo Keytek ECAT Transient Generator System
SKU: 11321
Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.Pulse repetition: 1 shot/9 secondsPulse voltage (open circuit): 200V - 6.6kV ± 10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864In Stock -
Rent Rohde & Schwarz ESU40 EMI Test Receiver for CISPR and MIL-STD Testing
SKU: 30082
Frequency Range: 20 Hz to 40 GHz (DC coupled), 10 MHz to 40 GHz (AC coupled)Frequency Resolution: 0.01 HzFrequency Counter Resolution: 0.1 Hz to 10 kHzTest Standards: CISPR 16-1-1, MIL-STD-461Applications: Conducted Emissions, Radiated EmissionsInquire for Lead Time -
3ctest CWS 800 8kV Surge Combination Wave Simulator for IEC/EN 61000-4-5 up to 8 kV
SKU: sku-797
Weight: Approx 30 kg (66 lbs)Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse): Pulse conforms to IEC/EN 61000-4-5Coupling: Single Phase Built in, 16A, 250VAC, 120VDCDimensions: 19 inch/6uImpedance: 2 OhmMains & EUT Connections: 4mm banana plugPhase synchronization: 0°-360°, 1°step or randomPolarity: Positive, Negative, AlternatePulse current (short circuit): 0.1kA-3kA ±10%Pulse repetition: 1-999Pulse voltage (open circuit): 0.2kV - 8kV ±10%Standards Met: IEC 61000-4-5, UL1449 and more -
ETS-Lindgren 3142D Biconilog Antenna, 26 - 6000 MHz
SKU: 2841
Standards: IEC 61000-4-3,FMC 1278, GMW3097Antenna Factor (1 Meter): -23 to 8 dBiApplication/Test Type: RF EMC immunity testingConnector: N type femaleDimensions: 52.7 in. (133.9 cm) x 66.2 in (168.1 cm) x 30 in (76.2 cm)Frequency Range: 25 MHz - 6 GHzGain: 8 dBiMaximum Continuous Power: 500 WattsInquire For Lead Time -
Rent Com-Power LI-3P-132 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: 11124
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 32 AmperesDimensions: 19.3” x 13.9” x 2.3"Frequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VInquire for Availability -
Frankonia Core-6 EMI Receiver 9 kHz–6 GHz
SKU: 52535
Frequency ranges: 9 kHz – 30 MHz and 30 MHz – 6 GHzFully compliant: acc. to CISPR 16-1-1Fast measurements: by new digital designIntegrated: 20dB pre-amplifierIntegrated pulse limiter: Up to 30 MHzDetectors: Peak, quasi-peak, average, RMS, RMS-average, CISPR-averageAutomatic scan: And manual modeInterface: USB and RS-232 interfacePowerful software: For full-automatic emission measurements including control of turntable and antenna mastsPre-programmed test: runs acc. to CISPR standardsIn Stock -
Radiated Emissions Testing Equipment for FCC, MIL and More
SKU: sku-1164
Generic Standards: IEC 61000-6-3, IEC 61000-6-4 -
Com-Power LI-3P-132 150kHz to 30MHz Three-Phase Line Impedance Stabilization Network
SKU: sku-598
Weight: 30 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 32 AmperesFrequency Range: 150 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V$6,495.00