ANSI/IEEE Standards Categories
ANSI/IEEE Standards Test Equipment, Systems & Solutions
-
Haefely PIM 150 Oscillating Wave Surge Generator
SKU: 10526
Burst frequency: 100 kHz & 1 MHzCoupling: Single & Multiple PathMains & EUT Connections: HV connector & CDNSource Impedance: 200 ohmsStandards Met: IEC 61000-4-18 Power & Data lines; ANSI C37.90.1, IEC 60255-22-1, IEEE 1613In Stock -
Rent Solar 9247-50-TS-50-N LISN for CISPR 16-1, FCC Part 15, ANSI C63.4
SKU: sku-302
Application/Test Type: Power line conducted emissions testsCurrent Rating: 50 AmpsFrequency Range: 10 kHz to 50 MHzInductors: 50 µH (0.10 µF Coupling Capacitor)Mains & EUT Connections: Terminal ScrewRF Connector: 50Ω N-type (female)Standards Met: FCC Part 15, CISPR 16-1, ANSI C63.4 (1992)Voltage Rating: 500 VAC (Line to Ground), 800 VDC -
Com-Power LIN-120A LISN for CISPR 16-1-2/ANSI C63.4 w/ built-in Transient Limiter
SKU: sku-15
Weight: 10 lbs (4.5 kg)Application/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amps AC (rms) , 14 Amps DCDimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)Frequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUTRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2, ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
AH18G Active Horn Antenna for Radiated Emissions to 18 GHz
SKU: 2363
Applications: Radiated Emissions, Military & Aviation EMC TestingTest Standards: FCC Part 15, MIL-STD-461Gain: 30 dBMax Input Power: -10 dBm (97 dBµV)Power: Battery Operated & USB ChargerConnector: N-type (to Analyzer/Receiver)$695.00IN STOCK -
LISN-AC-CISPR16-10 Line Impedance Stabilization Network for CISPR16
SKU: sku-2323
EUT Current Handling: 10 AmpsEUT Voltage Handling: 250 VoltsInductance: 50 uHTest Standards: CISPR 16-1-2, VDE 0876, FCC part 15, MIL-STD 461, ISO 60601-1-2Applications: Conducted Emissions Testing, CE MarkingVideos: Debugging Failures$195.00IN STOCK -
Haefely FP-SURGE 100M 100 Amp Surge Immunity System
SKU: sku-2170
Test Capabilities: Combination Wave Surge ImmunityStandards Met: IEC/EN 61000-4-5 ANSI standards C62.41 and C62.45Applications: CE Marking, Medical Devices, Industrial Machinery, Electronics & ITMax EUT AC Voltage: 690 VoltsMax EUT Current: 100 AmpsImpulse Voltage: 8 kVImpulse Current: 4 kARENTAL ONLY -
ETS-Lindgren 3142E Biconilog Antenna, 30 MHz - 6 GHz
SKU: 14
Standards: IEC 61000-4-3,FMC 1278, GMW3097Gain: -23 to 8 dBiApplication/Test Type: RF EMC immunity testingFrequency Range: 30 MHz - 6 GHzMaximum Continuous Power: 500 WattsTypically In Stock -
Schwarzbeck NNLK 8121 100 Amp Line Impedance Stabilization Network
SKU: 10857
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 100 AmperesStandards Met: ANSI C63.4, CISPR 16-1-2Frequency Range: 9 kHz - 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705VTypically In Stock -
EMCO (ETS-Lindgren) 3810-2 LISN, NEMA, 9 kHz - 30 MHz, 10 Amps
SKU: 11287
Weight: 10.7 lbs. / 4.9 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 10 AmpsDimensions: 8.7 x 15 x 6 inches / 22.2 x 38.1 x 15.2 cmFrequency Range: 9 kHz to 30 MHzInductors: 50 µH/250µHMains & EUT Connections: NEMA typical. (SCHUKO and British available upon request)RF Connector: 50Ω BNC MonitorStandards Met: FCC 15, VDE 0871, VDE 0875Voltage Rating: 250 VAC (Line to Ground)$195.00In Stock -
Haefely PSURGE 8000 EMC Surge Platform with Expandable PIM Modules
SKU: 11411
Surge/Combination Wave: IEC/EN 61000-4-5 Ed. 1 & 2, ANSI C62.45Ring Wave: IEC/EN 61000-4-12, IEC/EN 61000-4-5 Ed. 1 & 2, ANSI C62.45Damped Oscillatory Wave: EC 61000-4-18, ANSI C37.90, IEC 60255-22-1, IEEE 1613Telecom Surge: IEC/EN 61000-4-5 , ITU K-series and IEC 60950In Stock -
Keytek E503 Ring Wave Simulator for ANSI/IEEE C62.4 and UL 864
SKU: sku-546
Pulse current (short circuit): Selectable at 200A max. or 500A max., when the open-circuit voltage is set to 6.0kV.Pulse repetition: 1 shot/9 secondsPulse voltage (open circuit): 200V - 6.6kV ± 10%Ringwave 0.5 μs/100 kHz: Pulse conforms to IEC/EN 61000-4-12 and ANSI (IEEE) C62.41Standards Met: ANSI/IEEE C62.41 Cat. A and B, and various UL standards, including UL 864IN STOCK -
Haefely PIM 100 Combination Wave Impulse Module
SKU: 10297
Output: Combination wave pulse 1, 2/50 - 8/20 μs (Hybrid-Surge pulse) up to 7.8kVCoupling (Max EUT Power): 3 Phase - 100 Amps, 690 VACTest Standards: IEC/EN 61000-4-5 Ed. 1 & 2, ANSI C62.45Applications: Surge immunity - Combo Wave, Ring Wave and Oscillatory Waves, EMC Precompliance TestingPulse current (short circuit): 0.1 – 3.7 kA ±10% (8 us ±20% risetime)Pulse repetition: 10 seconds / 6 per minuteFeatures: Impulse voltage and current monitorsIn Stock