ANSI/IEEE Standards Test Equipment, Systems & Solutions
-
RF/EMI Shielding Effectiveness Testing
SKU: sku-1900
Weight: 26 lbFrequency Range: 95 kHz (Crystal Controlled)Output Signal: Pulse modulated at approximately 600 Hz and has a 50% duty cycleReceiver: Two meter scales for high and low operation Aural output for headphone operation Battery operated for portable use Dynamic range of 120dBTransmitter Output: 1 Ampere RMS into an inductive load from approximately 5–50 μHy -
Com-Power LI-150C Line Impedance Stabilization Network
SKU: sku-890
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 50 Amps (AC), 35 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 5 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Com-Power LI-125C 150 kHz to 30 MHz Line Impedance Stabilization Network Pair
SKU: sku-881
Weight: 25 lbs. / 11.3 kgApplication/Test Type: Power line conducted emissions testsCurrent Rating: 25 Amps (AC), 17 Amps (DC)Dimensions: 13 x 7 x 7 inches / 33 x 17.7 x 17.7 cmFrequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: Superior Electric SUPERCON® shrouded socketsRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2 / ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
Rent Radiated Emissions Test System Using GTEM
SKU: 0869
Frequency Range: 30 MHz - 40 GHzDUT Size: up to 2' cubed (GTEM 750)EMI Measurements: FCC Part 15, CISPR 11, MIL-STD-461 and moreApplications: EMC Precompliance Testing, CE Marking, Radiated Emissions Testing$1,775.00IN STOCK -
Com-Power LI-3P-216 LISN, 9 kHz to 30 MHz, 50/250 uH, 500 VAC
SKU: 11665
Weight: 27.5 lbs.Application/Test Type: Power Line Conducted Emissions TestsCurrent Rating: 16 AmperesDimensions: 19.3” x 13.9” x 2.3"Frequency Range: 9 kHz to 30 MHzInductors: 50 µHInsertion loss: less than 0.7 dBIsolation: more than 40 dBMains & EUT Connections: Remote Interface Power Input Port 5.5/2.5 mm Power JackRF Connector: RF Measurement Port 50Ω - N-Type (female)Standards Met: ANSI C63.4, CISPR 16-1-2Voltage Rating: 500 Volts rms (line to line), 288 Volts rms (line to ground) Max DC Voltage: 705V$5,795.00SHIPS IN 3-5 DAYS -
Haefely PIM 150 Oscillating Wave Surge Generator
SKU: 10526
Burst frequency: 100 kHz & 1 MHzCoupling: Single & Multiple PathMains & EUT Connections: HV connector & CDNSource Impedance: 200 ohmsStandards Met: IEC 61000-4-18 Power & Data lines; ANSI C37.90.1, IEC 60255-22-1, IEEE 1613In Stock -
Rent Solar 9247-50-TS-50-N LISN for CISPR 16-1, FCC Part 15, ANSI C63.4
SKU: sku-302
Application/Test Type: Power line conducted emissions testsCurrent Rating: 50 AmpsFrequency Range: 10 kHz to 50 MHzInductors: 50 µH (0.10 µF Coupling Capacitor)Mains & EUT Connections: Terminal ScrewRF Connector: 50Ω N-type (female)Standards Met: FCC Part 15, CISPR 16-1, ANSI C63.4 (1992)Voltage Rating: 500 VAC (Line to Ground), 800 VDC -
Keysight (Agilent) N9038A-526 MXE EMI Receiver, 3 Hz to 26.5 GHz
SKU: 10259
Frequency Range: 20 Hz - 26.5 GHzResolution: 2 HzBandwidth accuracy (–3.01 dB): 1 Hz to 1.3 MHz ± 2 % (nominal)Dynamic Range: > 70 dBAmplitude Accuracy: < ± 2.7 dBEMC Standards: CISPR 11, CISPR 22, ANSI C63.2Typically In Stock -
Com-Power LIN-120A LISN for CISPR 16-1-2/ANSI C63.4 w/ built-in Transient Limiter
SKU: sku-15
Weight: 10 lbs (4.5 kg)Application/Test Type: Power line conducted emissions testsCurrent Rating: 20 Amps AC (rms) , 14 Amps DCDimensions: 6.6” x 14.3” x 13” (16.8 x 36.3 x 33 cm)Frequency Range: 150 kHz to 30 MHzInductors: 50 µH (air-core)Insertion Loss: 0.5 dB (150 kHz to 30 MHz)Isolation: 40 dB (150 kHz to 30 MHz)Mains & EUT Connections: IEC 60320 @Mains and NEMA 5-15R @EUTRF Connector: 50Ω N-type (female)Standards Met: CISPR 16-1-2, ANSI C63.4Voltage Rating: 270 VAC (Line to Ground), 380 VDC -
RESA7G Realtime EMI Measurement Analyzer
SKU: 2075-1
Applications: Conducted Emissions, Radiated Emissions, Spectrum Analyzers for EMCPre-programmed Test Limits: FCC Part 15, CISPR 22, MIL-STD-461Frequency Range: 9 kHz - 7 GHzSweep/Test Speed: FastAmplitude Accuracy: <0.7 dBResolution Bandwidth: 1 Hz to 3 MHz$695.00In Stock -
ETS-Lindgren 3142E Biconilog Antenna, 30 MHz - 6 GHz
SKU: 10814
Standards: IEC 61000-4-3, FMC 1278, GMW3097Gain: -23 to 8 dBiApplication/Test Type: RF EMC immunity testingFrequency Range: 30 MHz - 6 GHzMaximum Continuous Power: 500 WattsTypically In Stock -
AH18G Active Horn Antenna for Radiated Emissions to 18 GHz
SKU: 2363